Network Configuration
Raw TCP/IP Printing
Raw TCP/IP is a printing method used to open a TCP
Basic Settings
Notes:
•TCP/IP must be enabled before Raw TCP/IP Printing is enabled.
•Raw TCP/IP printing is selected in Windows 2000 as the Standard TCP/IP port.
•If your printer is locked, you must log in as a system administrator. For details, see Accessing CentreWare IS on page 17.
1.In CentreWare IS, click Connectivity > Protocols > Raw TCP/IP Printing.
2.Select Enabled to enable the protocol.
3.Ensure that the TCP Port Number is set to 9100 for Port 1.
Note: To emulate HP JetDirect EX Plus 3, set Port 2 to 9101 and Port 3 to 9102.
4.Select Enabled for Bidirectional communication.
5.Ensure that Maximum Connections per port
6.Set the End of Job Timeout to the desired number of seconds between
7.Select Enabled for PDL Switching to allow the printer to automatically switch between multiple supported PDLs within a single job.
Note: PDL Switching should normally be disabled.
8.Click Apply to accept the changes or Undo to retain the previous settings. To set all fields to printer default values, click Default All.
9.Click OK.
Advanced Settings
Additional Raw TCP/IP Printing options can be specified in the Advanced page. These include:
1.Connections
•Total Job Limit per Connection: Type a value between 0 and 32768 to limit the number of jobs that can be active for each port.
•Maximum concurrent connections
•Maximum concurrent jobs: Type a value between 0 and 500 to specify the maximum number of concurrent jobs. A setting of 0 allows unlimited concurrent jobs.
2.Job Boundary Determination
•Enable Control D Marks End of PostScript Job if you want the Control D character to be used to indicate the end of a PostScript print job.
34WorkCentre 7755/7765/7775 Multifunction Printer System Administrator Guide