Format Details 291

change.

STATUS

11110000

F0

System exclusive message

ID No.

01000011

43

Manufacture's ID number (YAMAHA)

SUB STATUS

0001nnnn

1n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110

3E

MODEL ID (digital mixer)

MODEL ID

00001011

0B

02R96

ADDRESS

00100001

21

Address UU

 

0aaaaaaa

aa

Address UL

 

0aaaaaaa

aa

Address LU

 

0aaaaaaa

aa

Address LL

DATA

0ddddddd

dd

Data1 H

 

0ddddddd

dd

Data1 L

 

:

 

 

EOX

11110111

F7

End of exclusive

Meter data uses the unmodified DECAY value of the DSP. For the interpretation of the value, refer to the PARAMETER CHANGE PARAMETER NUMBER LIST.

12.3.22 Parameter request (Remote Meter)

Reception

This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS.

This is echoed if [Parameter change ECHO] is ON.

When this is received, the parameter specified by Address (refer to PARAMETER CHANGE PARAMETER NUMBER LIST) will be transmitted on the [Rx CH] at 50 msec intervals for a duration of 10 seconds.

If Address UL= 0x7F is received, transmission of all meter data will be halted immediately. (disable)

Transmission

If [Parameter Change ECHO] is ON, this message is retransmitted without change.

STATUS

11110000

F0

System exclusive message

ID No.

01000011

43

Manufacture's ID number (YAMAHA)

SUB STATUS

0011nnnn

3n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110

3E

MODEL ID (digital mixer)

MODEL ID

00001011

0B

02R96

ADDRESS

00100001

21

Address UU

 

0aaaaaaa

aa

Address UL

 

0aaaaaaa

aa

Address LU

 

0aaaaaaa

aa

Address LL

DATA

0cccccccccc

Count H

 

0ccccccccCc

Count L

EOX

11110111

F7

End of exclusive

12.3.23 Parameter change (Remote Time Counter)

When transmission is enabled by receiving a Request of Remote Time Counter, the Time Counter data is transmitted every 50 msec for 10 sec- onds. When you want to transmit Counter information continuously, a Request must be transmitted within every 10 seconds.

Reception

This is echoed if [Parameter change ECHO] is ON.

Transmission

When transmission is enabled by receiving a Request, the Time Counter information is transmitted on [RxCH] channel every 50 msec for 10 sec- onds.

Transmission will be disabled if the power is turned off and on again, or if the PORT setting is changed.

If [Parameter Change ECHO] is ON, this message is retransmitted without change.

STATUS

11110000

F0

System exclusive message

ID No.

01000011

43

Manufacture's ID number (YAMAHA)

SUB STATUS

0001nnnn

1n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110

3E

MODEL ID (digital mixer)

MODEL ID

00001011

0B

02R96

ADDRESS

00100001

22

Remote Time Counter

 

0000tttt

0t

0:Time Code, 1: Measure, Beat, Clock

DATA

0ddddddd

dd

Hour / Measure H

 

0ddddddd

dd

Min / Measure L

 

0ddddddd

dd

Sec / Beat

 

0ddddddd

dd

Frame / Clock

EOX

11110111 F7 End of exclusive

12.3.24 Parameter request (Remote Time Counter)

Reception

This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS.

This is echoed if [Parameter change ECHO] is ON.

When this is received, the Time Counter information is transmitted on the [Rx CH] channel every 50 msec for 10 seconds.

When the second byte of Address is received on 0x7F, data transmission will be halted immediately.

Transmission

If [Parameter Change ECHO] is ON, this message is retransmitted without change.

STATUS

11110000

F0

System exclusive message

ID No.

01000011

43

Manufacture's ID number (YAMAHA)

SUB STATUS

0011nnnn

3n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110

3E

MODEL ID (digital mixer)

MODEL ID

00001011

0B

02R96

ADDRESS

00100001

22

Remote Time Counter

 

0aaaaaaa

aa

0:Transmission request,

 

 

 

0x7F:Transmission stop request

EOX

11110111

F7

End of exclusive

12.3.25 Parameter change (Automix Status)

When transmission is enabled by receiving a Request of Automix status, the Automix Status data is transmitted every second for 10 seconds. When you want to transmit the Automix Status information continuously, the Request must be transmitted continuously minimum within 10 seconds interval. The data is transmitted continuously while the transmission is en- abled, even when the Automix Status on the 02R96 has been changed.

Reception

This is echoed if [Parameter change ECHO] is ON.

Transmission

When the transmission is set to enable by receiving a Request. The Auto- mix Status data is transmitted on the [Rx CH] channel every second for 10 seconds. The data is transmitted continuously while the transmission is enabled, even when the Automix Status on the 02R96 has been changed. Transmission will be disabled if the power is turned off and on again, or if the PORT setting is changed.

If [Parameter Change ECHO] is ON, this message is retransmitted without change.

STATUS

11110000

F0

System exclusive message

ID No.

01000011

43

Manufacture's ID number (YAMAHA)

SUB STATUS

0001nnnn

1n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110

3E

MODEL ID (digital mixer)

MODEL ID

00001011

0B

02R96

ADDRESS

00100011

23

Automix Status

 

00000000

00

 

DATA

0000dddd

0d

Automix Status H

 

0000dddd

0d

Automix Status L

EOX

11110111

F7

End of exclusive

12.3.26 Parameter request (Automix Status)

Reception

This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS.

This is echoed if [Parameter change ECHO] is ON.

When the data is received, the Automix Status data is transmitted on the [Rx CH] every second for 10 seconds.

When the second byte of Address is received on 0x7F, data transmission will be halted immediately (disable).

Transmission

If [Parameter Change ECHO] is ON, this message is retransmitted without change.

STATUS

11110000

F0

System exclusive message

ID No.

01000011

43

Manufacture's ID number (YAMAHA)

SUB STATUS

0011nnnn

3n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110

3E

MODEL ID (digital mixer)

MODEL ID

00001011

0B

02R96

ADDRESS

00100011

23

Automix Status

 

0aaaaaaa

aa

0:Transmission request,

 

 

 

0x7F:Transmission stop request

EOX

11110111

F7

End of exclusive

02R96—Bedienungsanleitung