4. Direct connection by emulated serialization on parallel DIO

The master station PLC can exchange bit information data with the parallel port on the robot controller’s parallel I/O unit regardless of the robot program. By using this func- tion, I/O devices such as a sensor or relay can be used like a device connected to CC-Link.

n NOTE

When the directly connected and set output port is used with the program, the bit information may not become the intended value. Do not use the directly connected and set output port with the program.

Master station PLC

CC-Link connection

Remote device station robot controller

I/O device

Sensor, relay, etc.

Parallel I/O connection

3

n NOTE

When the port specified by SIO is identical with the port used by the program, the output results might be inaccurate.

4.1Emulated serialization setting on parallel DIO

The relation of the parallel port and serial port that can be connected is shown below.

Input device such as sensor

Output device such as valve

DI port

SO port

DO port

SI port

 

 

 

 

 

 

DI2()

 

SO2()

DO2()

 

SI2()

DI3()

 

SO3()

DO3()

 

SI3()

DI4()

 

SO4()

DO4()

 

SI4()

DI5()

 

SO5()

DO5()

 

SI5()

[Operation]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Press the F 3

(SIO) key in “SYSTEM > OPTION” mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM>OPTION>SIO

 

 

 

 

V8.01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Direct SI2() -> DO2()

 

 

NO

 

 

 

 

2.Direct SI3() -> DO3()

 

 

NO

 

 

 

3.Direct SI4() -> DO4()

 

 

NO

 

 

 

4.Direct SI5() -> DO5()

 

 

NO

 

 

 

5.Direct SO2() <- DI2()

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDIT

 

 

JUMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valid keys and submenu functions in this mode are as follows.

Valid keys

Menu

Function

 

 

 

Cursor (↑/↓) keys

 

Selects SIO parameters.

 

 

 

F1

EDIT

Sets SIO parameters.

 

 

 

F2

JUMP

Jumps to specified SIO parameter.

 

 

 

Communication

3-5

Page 39
Image 39
Yamaha Yamaha Robot Controller CC-Link Unit, RCX Series Direct connection by emulated serialization on parallel DIO