2. Details of remote input/output signals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device No.

 

 

Signal name

 

 

Details

 

 

 

RY(n+1)0

 

 

 

 

 

 

 

 

 

 

to

 

SI(20) to SI(27): General-purpose input

 

 

 

 

 

 

RY(n+1)7

 

 

 

 

 

 

 

 

 

 

to

 

 

to

 

 

Set these inputs to ON or OFF to refer to SI port

 

 

 

 

 

 

 

values or execute WAIT command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY(n+6)8

 

 

 

 

 

 

 

 

 

 

to

 

SI(150) to SI(157): General-purpose input

 

 

 

 

 

 

RY(n+6)F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turns ON when power is turned ON,

 

 

 

 

 

 

 

 

 

communication error is reset, or data initialization is

 

 

 

RY(n+7)8

Initial data process complete flag

 

requested or completed.

 

 

 

 

 

 

 

 

 

Emergency stop input (RYn0) and interlock input

 

 

 

 

 

 

 

 

 

(RYn9) are turned ON when data is initialized.

 

 

 

 

 

 

 

n: Address assigned to master module with station No. setting

 

 

 

 

 

 

 

 

 

 

Device No.

 

Name

 

Details

 

 

 

RWwn

 

 

Dedicated SIW(0)

 

Used as the remote command area.

 

 

 

RWw(n+1)

 

 

Dedicated SIW(1)

 

Used as the remote command’s command

 

 

 

 

 

 

data area.

 

 

 

 

 

 

 

 

 

 

 

 

 

RWw(n+2)

 

General-purpose

General-purpose SIW(2)

 

 

 

 

RWw(n+3)

 

SID(2)

General-purpose SIW(3)

 

 

 

 

RWw(n+4)

 

General-purpose

General-purpose SIW(4)

 

 

 

 

RWw(n+5)

 

SID(4)

General-purpose SIW(5)

 

 

 

 

RWw(n+6)

 

General-purpose

General-purpose SIW(6)

 

 

 

 

RWw(n+7)

 

SID(6)

General-purpose SIW(7)

Used to input word or double word data

 

 

 

RWw(n+8)

 

General-purpose

General-purpose SIW(8)

from SIW or SID port.

 

 

 

RWw(n+9)

 

SID(8)

General-purpose SIW(9)

Or, used as remote command’s command

 

 

 

RWw(n+10)

General-purpose

General-purpose SIW(10)

data area.

 

 

 

RWw(n+11)

SID(10)

General-purpose SIW(11)

 

 

 

 

RWw(n+12)

General-purpose

General-purpose SIW(12)

 

 

 

 

RWw(n+13)

SID(12)

General-purpose SIW(13)

 

 

 

 

RWw(n+14)

General-purpose

General-purpose SIW(14)

 

 

 

 

RWw(n+15)

SID(14)

General-purpose SIW(15)

 

 

 

 

 

 

 

 

n: Address assigned to master module with station No. setting

 

 

 

 

 

 

 

 

 

Device No.

 

Name

 

Details

 

 

 

RWrn

 

 

Dedicated SOW(0)

 

Used as remote command’s status area.

 

 

 

RWr(n+1)

 

 

Dedicated SOW(1)

 

Used as remote command’s error

 

 

 

 

 

 

code area.

 

 

 

 

 

 

 

 

 

 

 

 

 

RWr(n+2)

 

General-purpose

General-purpose SOW(2)

 

 

 

 

RWr(n+3)

 

SOD(2)

General-purpose SOW(3)

 

 

 

 

RWr(n+4)

 

General-purpose

General-purpose SOW(4)

 

 

 

 

RWr(n+5)

 

SOD(4)

General-purpose SOW(5)

 

 

 

 

RWr(n+6)

 

General-purpose

General-purpose SOW(6)

 

 

 

 

RWr(n+7)

 

SOD(6)

General-purpose SOW(7)

Used to output word or double word data

 

 

 

RWr(n+8)

 

General-purpose

General-purpose SOW(8)

from SOW or SOD port.

 

 

 

RWr(n+9)

 

SOD(8)

General-purpose SOW(9)

Or, used as remote command’s response

 

 

 

RWr(n+10)

 

General-purpose

General-purpose SOW(10)

area.

 

 

 

RWr(n+11)

 

SOD(10)

General-purpose SOW(11)

 

 

 

 

RWr(n+12)

 

General-purpose

General-purpose SOW(12)

 

 

 

 

RWr(n+13)

 

SOD(12)

General-purpose SOW(13)

 

 

 

 

RWr(n+14)

 

General-purpose

General-purpose SOW(14)

 

 

 

 

RWr(n+15)

 

SOD(14)

General-purpose SOW(15)

 

 

 

 

 

 

 

 

n: Address assigned to master module with station No. setting

5

Specifications

5-5

Page 59
Image 59
Yamaha Yamaha Robot Controller CC-Link Unit, RCX Series owner manual Details of remote input/output signals