Ryobi RYI2000T manuel dutilisation Specific Safety Rules

Page 8

IMPORTANT SAFETY INSTRUCTIONS

Use only authorized replacement parts and accessories and follow instructions in the Maintenance section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of shock or injury.

Maintain the unit per maintenance instructions in this Operator’s Manual.

Inspect the unit before each use for loose fasteners, fuel leaks, etc. Replace damaged parts.

SPECIFIC SAFETY RULES

WARNING:

When this generator is used to supply a building wiring system: generator must be installed by a qualified electrician and connected to a transfer switch as a separately derived system in accordance with NFPA 70, National Electrical Code. The generator shall be connected through a transfer switch that switches all conductors other than the equipment grounding conductor. The frame of the generator shall be connected to an approved grounding electrode. Failure to isolate the generator from power utility can result in death or injury to electric utility workers.

Do not use this generator to provide power for emergency medical equipment or life support devices.

Exhaust contains poisonous carbon monoxide, a color- less, odorless gas. Breathing exhaust can cause loss of consciousness and can lead to death. If running in a confined or partially-enclosed area, the air may contain a dangerous amount of carbon monoxide. To keep ex- haust fumes from building up, always provide adequate ventilation.

Always use a battery-powered carbon monoxide detec- tor when running the generator. If you begin to feel sick, dizzy, or weak while using the generator, shut it off and get to fresh air immediately. See a doctor. You may have carbon monoxide poisoning.

Place the generator on a flat, stable surface with a slope of no more than 4°.

Operate outdoors in a well-ventilated, well-lit area isolated from working areas to avoid noise interference.

Operating the generator in wet conditions could result in electrocution. Keep the unit dry.

Keep the generator a minimum of 3 feet away from all types of combustible material.

Do not operate generator near hazardous material.

Do not operate generator at a gas or natural gas filling station.

Do not touch the muffler or cylinder during or immediately after use; they are HOT and will cause burn injury.

This generator has a neutral floating condition. This means the neutral conductor is not electrically connected to the frame of the machine.

Do not allow the generator’s gas tank to overflow when filling. Fill to 1 in. below the top neck of the gasoline tank to allow for fuel expansion. Do not cover the fuel tank cap when the engine is running. Covering the fuel tank cap during use may cause engine failure and/or damage to the tool.

Do not smoke when filling the generator with gasoline.

Shut down the engine and allow to cool completely before adding gasoline or lubricant to the generator.

Do not remove the oil dipstick or the fuel tank cap when the engine is running.

Pay close attention to all safety labels located on the generator.

Keep children a minimum of 10 feet away from the gen- erator at all times.

The unit operates best in temperatures between 23°F and 104°F with a relative humidity of 90% or less.

Specific modifications for high-altitude performance are needed if the generator will always be operated at alti- tudes above 5,000 feet. Contact your nearest authorized service center for more information and to have these modifications performed.

Operating voltage and frequency requirement of all electronic equipment should be checked prior to plug- ging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings.

Save these instructions. Refer to them frequently and use them to instruct others who may use this product. If you loan someone this product, loan them these instructions also.

4 — English

Image 8
Contents Flottante Neutre / Neutral DE Flotación Save this Manual for Future ReferenceNeutral Floating Page Iii Off arret, apagado On marche, encendido OFF Idle WER Table of Contents IntroductionImportant Safety Instructions Specific Safety Rules Symbol Signal Meaning SymbolsSymbol Name DESIGNATION/EXPLANATION Safety Labels Name DESIGNATION/EXPLANATIONExtension Cord Cable Size ElectricalAvertissement Example Electric Motor LoadsGenerator Capacity Features Power ManagementProduct Specifications Engine GeneratorAuto Idle Switch Battery Charging CableON/OFF Switch Know Your GeneratorPacking List AssemblyUnpacking Operation Before Operating the UnitCHECKING/ADDING Lubricant ApplicationsUsing Fuel Stabilizer CHECKING/ADDING FuelOxygenated Fuels Opening and Closing Vented Fuel CAPMaintenance Using the Battery Charging CableGeneral Maintenance To clean the unitCHECKING/CLEANING AIR Filter Spark Plug ReplacementChanging Engine Lubricant Draining Fuel TANK/CARBURETORMaintenance Schedule Troubleshooting Problem Possible Cause SolutionWarranty Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage PURCHASER’S/OWNER’S Warranty ResponsibilitiesLimited Engine Warranty Warranty PeriodsLimited Warranty Statement Páge arrière Table DES MatièresMise À LA Terre DU Générateur Instructions Importantes Concernant LA Sécurité Conserver CES InstructionsRègles DE Sécurité Particulières Symbole Signal Signification SymbolesSymbole NOM Désignation / Explication Autocollants DE Sécurité NOM Désignation / ExplicationCaractéristiques Électriques Taille DU Câble DU Cordon ProlongateurCharges DU Moteur Électrique Capacité DU GénérateurCaractéristiques Gestion DE L’ÉNERGIEFiche Technique MoteurBien Connaître LE Générateur Prises DE 120 V C.AFiltre À AIR ModedemarcheauralentiautomatiqueListe DE Contrôle D’EXPÉDITION AssemblageDéballage VÉRIFICATION/AJOUT DE Lubrifiant UtilisationAvant D’UTILISER L’UNITÉ VÉRIFICATION/AJOUT DE Carburant Carburants OxygénésOuverture ET Fermeture DU Bouchon DE Carburant Ventilé Utilisation DE Stabilisateur DE CarburantDéplacement DU Générateur EntretienArrêt DU Moteur Fonctionnement DES Câble Pour Charger LES PilesEntretien Général INSPECTION/NETTOYAGE DU Filtre À AIRChangement Huile DE Moteur Entretien DE LA BougieCalendrier D’ENTRETIEN Transport Problème Cause Possible Solution DépannageArrêt O Marche La figureGarantie VOS Droits ET Responsabilités EN Vertu DE Cette GarantieÉnoncé DE LA Garantie Limitée DU Moteur Énoncé DE LA Garantie Limitée Peligro Conexión a Tierra DEL Generador Índice DE ContenidoIntroducción Instrucciones DE Seguridad Importantes PeligroAdvertencia Guarde Estas InstruccionesReglas DE Seguridad Específicas Símbolos PrecauciónSímbolo Nombre Denominación / Explicación Símbolo Señal SignificadoEtiquetas DE Seguridad Nombre Denominación / ExplicaciónCalibre DEL Cordón DE Extensión Aspectos EléctricosAvertissement Ejemplo Cargas DE Motores EléctricosCapacidad DEL Generador Administración DE LA Potencia CaracterísticasEspecificaciones DEL Producto PrecauciónFamiliarícese CON EL Generador Receptáculos DE 120 V, C.AFiltro DE Aire Interruptor DE Ralentí AutomáticoLista DE Empaquetado ArmadoDesempaquetado Funcionamiento AplicacionesAntes DE Accionar LA Unidad Verificación Y Abastecimiento DE LubricanteVerificación Y Abastecimiento DE Combustible USO DE Estabililzador DE CombustibleCombustibles Oxigenados Abertura Y Cierre DE LA Tapa DE Combustible VenteadaMantenimiento Apagado DEL MotorUtilizando EL Cable Para Cargar Baterías Traslado EL GeneradorRevisión Y Limpieza DEL Filtro DE Aire Cambio DE Aceite DE MotorMantenimiento DE LA Bujía Drenaje DEL Tanque DEL Combustible Y DEL CarburadorPrograma DE Mantenimiento TransporteCorrección DE Problemas Problema Causa Posible SoluciónApagado O Encendido La figuraGarantía Derechos Y Obligaciones DE SU GarantíaPeríodos DE Garantía Limitaciones Y Exclusiones Esta Garantía limitada no cubriráDeclaración DE LA Garantía Limitada English Manuel D’UTILISATION Manual DEL Operador Lávese las manos después de utilizar el aparatoDigital Inverter Generator RYi2000T