Intel 5400 Series manual Tcontrol Definition, Equation 2-2.TCONTROL= -TOFFSET

Page 25

Thermal/Mechanical Reference Design

above, the case-to-ambient resistance represents the slope of the line and the processor local ambient temperature represents the y-axis intercept. Hence the

TCASE_MAX value of a specific solution can be calculated at TDP. Once this point is determined, the line can be extended to Power (P) = 0W representing the Thermal

Profile of the specific solution. If that line stays at or below the Thermal Profile specification, then that particular solution is deemed as a compliant solution.

2.2.6TCONTROL Definition

TCONTROL can be described as a trigger point for fan speed control implementation. The processor TCONTROL value provided by the Digital Thermal Sensor is relative and no longer absolute. The TCONTROL value is now defined as a relative value to the TCC activation set point (i.e. PECI Count = 0), as indicated by PROCHOT#. Figure 2-8

depicts the interaction between the TCONTROL value and Digital Thermal Sensor value.

Figure 2-8. TCONTROL Value and Digital Thermal Sensor Value Interaction

Digital Thermal Sensor Temperature

0

Tcontrol = -5

-10Temperature

-20

-30

-40

Time

The value for TCONTROL is calibrated in manufacturing and configured for each processor individually. For the Quad-Core Intel® Xeon® Processor 5400 Series, the TCONTROL value is obtained by reading the processor model specific register

(IA32_TEMPERATURE_TARGET MSR).

Note: There is no TCONTROL_BASE value to sum as previously required on legacy processors. The fan speed control device only needs to read the TOFFSET MSR and compare this to the DTS value from the PECI interface. The equation for calculating TCONTROL is:

Equation 2-2.TCONTROL= -TOFFSET

Where:

TOFFSET = A DTS-based value programmed into each processor during manufacturing that can be obtained by reading the

IA32_TEMPERATURE_TARGET MSR. This is a static and a unique value. Refer to the RS - Wolfdale Processor Family BIOS Writer’s Guide (BWG) for further details.

Quad-Core Intel® Xeon® Processor 5400 Series TMDG

25

Image 25
Contents Thermal/Mechanical Design Guidelines Quad-Core Intel Xeon Processor 5400 SeriesQuad-Core Intel Xeon Processor 5400 Series Tmdg Contents Figures Preload Test Configuration Tables Initial release of the document Reference Revision Description Date NumberQuad-Core Intel Xeon Processor 5400 Series Tmdg Scope ObjectiveReferences Terms and Descriptions Sheet 1 Definition of TermsTerm Description TDP Terms and Descriptions Sheet 2Introduction Processor Mechanical Parameters Mechanical RequirementsProcessor Mechanical Parameters Table Parameter Minimum Maximum UnitQuad-Core Intel Xeon Processor 5400 Series Package Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design Quad-Core Intel Xeon Processor 5400 Series Considerations Thermal Control Circuit and TDP Processor Thermal Parameters and FeaturesDigital Thermal Sensor Multiple Core Special Considerations Platform Environmental Control Interface PeciMultiple Digital Thermal Sensor Operation PROCHOT#, THERMTRIP#, and FORCEPR# Thermal Monitor for Multiple Core ProductsHeatpipe Orientation for Multiple Core Processors Processor Input Processor OutputFeature Dimension Processor Core Geometric Center DimensionsEquation 2-1.y = ax + b Thermal ProfileEquation 2-2.TCONTROL= -TOFFSET Tcontrol DefinitionTcontrol and Thermal Profile Interaction Thermal Profile B Performance Targets Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design 2U+ CEK, Thermal Profile a Parameter Maximum Unit1U CEK, Thermal Profile B Sea-Level Fan Fail Guidelines1U Alternative Heatsink Fan Speed Control Characterizing Cooling Solution Performance RequirementsFan Speed Control, Tcontrol and DTS Relationship Processor Thermal Characterization Parameter RelationshipsEquation 2-3.ΨCA= Tcase TLA / TDP Condition FSC SchemeEquation 2-4.ΨCA= ΨCS + ΨSA ExampleChassis Thermal Design Capabilities and Improvements Chassis Thermal Design ConsiderationsEquation 2-5.ΨCA= Tcase TLA / TDP = 68 45 / 85 = 0.27 C/W Equation 2-6.ΨSA= ΨCA − ΨCS = 0.27 − 0.05 = 0.22 C/WThermal/Mechanical Reference Design Considerations Heatsink SolutionsHeatsink Design Considerations Summary Thermal Interface MaterialGeometric Envelope Assembly DrawingStructural Considerations of CEK 17 U+ CEK Heatsink Thermal Performance Thermal Solution Performance CharacteristicsEquation 2-8.y = 0.187*X + Thermal Profile AdherenceEquation 2-9.y = 0.246*X + =0.187* X +40Equation 2-10.y = 0.246*X + 1UCEKReference SolutionHeatsink with Captive Screws and Standoffs Components Overview22. Isometric View of the 2U+ CEK Heatsink Recommended Thermal Grease Dispense Weight CEK Heatsink Thermal Mechanical CharacteristicsThermal Interface Material TIM Processor Minimum Maximum Units24. CEK Spring Isometric View CEK SpringThermal/Mechanical Reference Design Fan Specifications Boxed 4-wire PWM/DTS Heatsink Solution Fan Power SupplyDescription Min Typ Max Unit Steady Startup Systems Considerations Associated with the Active CEK Boxed Processor ContentsThermal/Mechanical Reference Design Figure A-1. Isometric View of the 1U Alternative Heatsink Component OverviewThermal Profile Adherence Thermal Solution Performance CharactericsEquation A-1. y = 0.331*x + = Processor power value W 1U Alternative Heatsink Thermal/Mechanical Design Drawing Description Table B-1. Mechanical Drawing ListFigure B-1 2U CEK Heatsink Sheet 1 Figure B-2 2U CEK Heatsink Sheet 2 Figure B-3 U CEK Heatsink Sheet 3 Figure B-4 2U CEK Heatsink Sheet 4 Figure B-5. CEK Spring Sheet 1 Figure B-6. CEK Spring Sheet 2 Figure B-7. CEK Spring Sheet 3 Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Figure B-14 U CEK Heatsink Sheet 1 Figure B-15 U CEK Heatsink Sheet 2 Figure B-16 U CEK Heatsink Sheet 3 Figure B-17 U CEK Heatsink Sheet 4 Figure B-18. Active CEK Thermal Solution Volumetric Sheet 1 Figure B-19. Active CEK Thermal Solution Volumetric Sheet 2 Figure B-20. Active CEK Thermal Solution Volumetric Sheet 3 Figure B-21 U Alternative Heatsink 1 Figure B-22 U Alternative Heatsink 2 Figure B-23 U Alternative Heatsink 3 Figure B-24 U Alternative Heatsink 4 Mechanical Drawings Test Preparation OverviewHeatsink Preparation Alternate Heatsink Sample Preparation Figure C-3. Preload Test Configuration Time-Zero, Room Temperature Preload Measurement Test Procedure ExamplesTypical Test Equipment Table C-1. Typical Test EquipmentPreload Degradation under Bake Conditions Heatsink Clip Load Methodology Safety Requirements Safety Requirements Structural Reliability Testing Environmental Reliability TestingIntel Verification Criteria for the Reference Designs Reference Heatsink Thermal VerificationPost-Test Pass Criteria 2.2 Recommended Test SequenceTable E-1 Use Conditions Environment Material and Recycling Requirements Recommended BIOS/Processor/Memory Test ProceduresQuality and Reliability Requirements Supplier Information Intel Enabled SuppliersFor 1U Additional Suppliers2U Heatsink Alternative CEK Copper Fin Alternative CEK Copper Fin Enabled Suppliers Information 100 Quad-Core Intel Xeon Processor 5400 Series Tmdg