Table | Terms and Descriptions (Sheet 2 of 2) | |
|
|
|
| TCONTROL | A processor unique value for use in fan speed control mechanisms. TCONTROL is a |
|
| temperature specification based on a temperature reading from the processor’s Digital |
|
| Thermal Sensor. TCONTROL can be described as a trigger point for fan speed control |
|
| implementation. TCONTROL = |
| TOFFSET | An offset value from the TCC activation temperature value programmed into each |
|
| processor during manufacturing and can be obtained by reading the |
|
| IA_32_TEMPERATURE_TARGET MSR. This is a static and a unique value. Refer to the |
|
| RS - Wolfdale Processor Family BIOS Writers Guide (BWG) for further details. |
|
|
|
| TDP | Thermal Design Power: Thermal solution should be designed to dissipate this target |
|
| power level. TDP is not the maximum power that the processor can dissipate. |
|
|
|
| Thermal Monitor | A feature on the processor that can keep the processor’s die temperature within factory |
|
| specifications under normal operating conditions. |
|
|
|
| Thermal Profile | Line that defines case temperature specification of a processor at a given power level. |
|
|
|
| TIM | Thermal Interface Material: The thermally conductive compound between the heatsink |
|
| and the processor case. This material fills the air gaps and voids, and enhances the |
|
| transfer of the heat from the processor case to the heatsink. |
|
|
|
| TLA | The measured ambient temperature locally surrounding the processor. The ambient |
|
| temperature should be measured just upstream of a passive heatsink or at the fan inlet |
|
| for an active heatsink. |
|
|
|
| TSA | The system ambient air temperature external to a system chassis. This temperature is |
|
| usually measured at the chassis air inlets. |
UA unit of measure used to define server rack spacing height. 1U is equal to 1.75 in, 2U equals 3.50 in, etc.
§