|
| Introduction |
Table |
| |
|
|
|
| Document | Comment |
|
|
|
| Available electronically | |
| CEK Thermal Models (in Flotherm* and Icepak*) |
|
|
|
|
| Available electronically | |
| Models (in Flotherm and Icepak) |
|
|
|
|
| RS - Wolfdale Processor Family BIOS Writers Guide (BWG) | See Note following table. |
|
|
|
| Thin Electronics Bay Specification (A Server System Infrastructure (SSI) | www.ssiforum.com |
| Specification for Rack Optimized Servers |
|
|
|
|
Note: Contact your Intel field sales representative for the latest revision and order number of this document.
1.4Definition of Terms
Table | Terms and Descriptions (Sheet 1 of 2) | |
|
|
|
| Term | Description |
|
|
|
| Bypass | Bypass is the area between a passive heatsink and any object that can act to form a |
|
| duct. For this example, it can be expressed as a dimension away from the outside |
|
| dimension of the fins to the nearest surface. |
|
|
|
| DTS | Digital Thermal Sensor replaces the Tdiode in previous products and uses the same |
|
| sensor as the PROCHOT# sensor to indicate the |
|
| value represents the number of degrees below the TCC activation temperature. |
|
|
|
| MSR | The processor provides a variety of model specific registers that are used to control and |
|
| report on processor performance. Virtually all MSRs handle system related functions and |
|
| are not accessible to an application program. |
|
|
|
| FMB | Flexible Motherboard Guideline: an estimate of the maximum value of a processor |
|
| specification over certain time periods. System designers should meet the FMB values to |
|
| ensure their systems are compatible with future processor releases. |
|
|
|
| FSC | Fan Speed Control |
|
|
|
| IHS | Integrated Heat Spreader: a component of the processor package used to enhance the |
|
| thermal performance of the package. Component thermal solutions interface with the |
|
| processor at the IHS surface. |
|
|
|
| LGA771 Socket | The |
|
| through this surface mount, 771 Land socket. See the LGA771 Socket Mechanical |
|
| Design Guide for details regarding this socket. |
|
|
|
| PMAX | The maximum power dissipated by a semiconductor component. |
| PECI | A proprietary |
|
| Intel processor and chipset components to external thermal monitoring devices, for use |
|
| in fan speed control. PECI communicates readings from the processors Digital Thermal |
|
| Sensor. PECI replaces the thermal diode available in previous processors. |
|
|
|
| ΨCA | |
|
| solution performance using total package power. Defined as (TCASE – TLA) / Total |
|
| Package Power. Heat source should always be specified for Ψ measurements. |
|
|
|
| ΨCS | |
|
| material performance using total package power. Defined as (TCASE – TS) / Total |
|
| Package Power. |
|
|
|
| ΨSA | |
|
| performance using total package power. Defined as (TS – TLA) / Total Package Power. |
| TCASE | The case temperature of the processor, measured at the geometric center of the topside |
|
| of the IHS. |
|
|
|
| TCASE_MAX | The maximum case temperature as specified in a component specification. |
| TCC | Thermal Control Circuit: Thermal monitor uses the TCC to reduce the die temperature |
|
| by using clock modulation and/or operating frequency and input voltage adjustment |
|
| when the die temperature is very near its operating limits. |
|
|
|
10 |
|