Intel 5400 Series manual Tables

Page 6

Tables

1-1

Reference Documents

9

1-2

Terms and Descriptions

10

2-1

Processor Mechanical Parameters Table

13

2-2

Input and Output Conditions for the Quad-Core Intel® Xeon® Processor 5400

 

 

Series Thermal Management Features

22

2-3

Processor Core Geometric Center Dimensions

23

2-4

Intel Reference Heatsink Performance Targets for the Quad-Core Intel®

 

 

Xeon® Processor X5400 Series

31

2-5

Intel Reference Heatsink Performance Targets for the Quad-Core Intel®

 

 

Xeon® Processor E5400 Series

32

2-6

Fan Speed Control, TCONTROL and DTS Relationship

34

2-7

CEK Heatsink Thermal Mechanical Characteristics

47

2-8

Recommended Thermal Grease Dispense Weight

47

2-9

Fan Specifications (Boxed 4-wire PWM/DTS Heatsink Solution)

50

2-10

Fan Cable Connector Pin Out (Active CEK)

51

A-1

1U Alternative Heatsink Thermal Mechanical Characteristics

54

B-1

Mechanical Drawing List

57

C-1

Typical Test Equipment

86

E-1

Use Conditions Environment

92

F-1

Suppliers for the Quad-Core Intel® Xeon® Processor 5400 Series Intel

 

 

Reference Solution

95

F-2

Additional Suppliers for the Quad-Core Intel® Xeon® Processor 5400 Series

 

 

Intel Reference Solution

97

6

Quad-Core Intel® Xeon® Processor 5400 Series TMDG

Image 6
Contents Quad-Core Intel Xeon Processor 5400 Series Thermal/Mechanical Design GuidelinesQuad-Core Intel Xeon Processor 5400 Series Tmdg Contents Figures Preload Test Configuration Tables Reference Revision Description Date Number Initial release of the documentQuad-Core Intel Xeon Processor 5400 Series Tmdg Objective ScopeReferences Definition of Terms Terms and Descriptions Sheet 1Term Description Terms and Descriptions Sheet 2 TDPIntroduction Processor Mechanical Parameters Table Mechanical RequirementsProcessor Mechanical Parameters Parameter Minimum Maximum UnitQuad-Core Intel Xeon Processor 5400 Series Package Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design Quad-Core Intel Xeon Processor 5400 Series Considerations Processor Thermal Parameters and Features Thermal Control Circuit and TDPDigital Thermal Sensor Platform Environmental Control Interface Peci Multiple Core Special ConsiderationsMultiple Digital Thermal Sensor Operation Heatpipe Orientation for Multiple Core Processors Thermal Monitor for Multiple Core ProductsPROCHOT#, THERMTRIP#, and FORCEPR# Processor Input Processor OutputProcessor Core Geometric Center Dimensions Feature DimensionThermal Profile Equation 2-1.y = ax + bTcontrol Definition Equation 2-2.TCONTROL= -TOFFSETTcontrol and Thermal Profile Interaction Thermal Profile B Performance Targets Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design Parameter Maximum Unit 2U+ CEK, Thermal Profile a1U CEK, Thermal Profile B Fan Fail Guidelines Sea-Level1U Alternative Heatsink Characterizing Cooling Solution Performance Requirements Fan Speed ControlEquation 2-3.ΨCA= Tcase TLA / TDP Processor Thermal Characterization Parameter RelationshipsFan Speed Control, Tcontrol and DTS Relationship Condition FSC SchemeExample Equation 2-4.ΨCA= ΨCS + ΨSAEquation 2-5.ΨCA= Tcase TLA / TDP = 68 45 / 85 = 0.27 C/W Chassis Thermal Design ConsiderationsChassis Thermal Design Capabilities and Improvements Equation 2-6.ΨSA= ΨCA − ΨCS = 0.27 − 0.05 = 0.22 C/WHeatsink Solutions Thermal/Mechanical Reference Design ConsiderationsHeatsink Design Considerations Thermal Interface Material SummaryAssembly Drawing Geometric EnvelopeStructural Considerations of CEK Thermal Solution Performance Characteristics 17 U+ CEK Heatsink Thermal PerformanceThermal Profile Adherence Equation 2-8.y = 0.187*X +=0.187* X +40 Equation 2-9.y = 0.246*X +1UCEKReference Solution Equation 2-10.y = 0.246*X +Components Overview Heatsink with Captive Screws and Standoffs22. Isometric View of the 2U+ CEK Heatsink Thermal Interface Material TIM CEK Heatsink Thermal Mechanical CharacteristicsRecommended Thermal Grease Dispense Weight Processor Minimum Maximum UnitsCEK Spring 24. CEK Spring Isometric ViewThermal/Mechanical Reference Design Fan Power Supply Fan Specifications Boxed 4-wire PWM/DTS Heatsink SolutionDescription Min Typ Max Unit Steady Startup Boxed Processor Contents Systems Considerations Associated with the Active CEKThermal/Mechanical Reference Design Component Overview Figure A-1. Isometric View of the 1U Alternative HeatsinkThermal Solution Performance Characterics Thermal Profile AdherenceEquation A-1. y = 0.331*x + = Processor power value W 1U Alternative Heatsink Thermal/Mechanical Design Table B-1. Mechanical Drawing List Drawing DescriptionFigure B-1 2U CEK Heatsink Sheet 1 Figure B-2 2U CEK Heatsink Sheet 2 Figure B-3 U CEK Heatsink Sheet 3 Figure B-4 2U CEK Heatsink Sheet 4 Figure B-5. CEK Spring Sheet 1 Figure B-6. CEK Spring Sheet 2 Figure B-7. CEK Spring Sheet 3 Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Figure B-14 U CEK Heatsink Sheet 1 Figure B-15 U CEK Heatsink Sheet 2 Figure B-16 U CEK Heatsink Sheet 3 Figure B-17 U CEK Heatsink Sheet 4 Figure B-18. Active CEK Thermal Solution Volumetric Sheet 1 Figure B-19. Active CEK Thermal Solution Volumetric Sheet 2 Figure B-20. Active CEK Thermal Solution Volumetric Sheet 3 Figure B-21 U Alternative Heatsink 1 Figure B-22 U Alternative Heatsink 2 Figure B-23 U Alternative Heatsink 3 Figure B-24 U Alternative Heatsink 4 Mechanical Drawings Overview Test PreparationHeatsink Preparation Alternate Heatsink Sample Preparation Figure C-3. Preload Test Configuration Typical Test Equipment Test Procedure ExamplesTime-Zero, Room Temperature Preload Measurement Table C-1. Typical Test EquipmentPreload Degradation under Bake Conditions Heatsink Clip Load Methodology Safety Requirements Safety Requirements Intel Verification Criteria for the Reference Designs Environmental Reliability TestingStructural Reliability Testing Reference Heatsink Thermal Verification2.2 Recommended Test Sequence Post-Test Pass CriteriaTable E-1 Use Conditions Environment Recommended BIOS/Processor/Memory Test Procedures Material and Recycling RequirementsQuality and Reliability Requirements Intel Enabled Suppliers Supplier InformationAdditional Suppliers For 1U2U Heatsink Alternative CEK Copper Fin Alternative CEK Copper Fin Enabled Suppliers Information 100 Quad-Core Intel Xeon Processor 5400 Series Tmdg