Intel 5400 Series manual Tcontrol and Thermal Profile Interaction

Page 26

Thermal/Mechanical Reference Design

Figure 2-9depicts the interaction between the Thermal Profile and TCONTROL.

Figure 2-9. TCONTROL and Thermal Profile Interaction

If the DTS temperature is less than TCONTROL, then the case temperature is permitted to exceed the Thermal Profile, but the DTS temperature must remain at or below

TCONTROL. The thermal solution for the processor must be able to keep the processor’s TCASE at or below the Thermal Profile when operating between the TCONTROL and TCASE_MAX at TDP under heavy workload conditions.

Refer to Section 2.4.1 for the implementation of the TCONTROL value in support of fan speed control (FSC) design to achieve better acoustic performance.

2.2.7Thermal Profile Concepts for the Quad-Core Intel® Xeon® Processor 5400 Series

2.2.7.1Dual Thermal Profile Concept for the Quad-Core Intel® Xeon® Processor X5400 Series

The Quad-Core Intel® Xeon® Processor X5400 Series is designed to go into various form factors, including the volumetrically constrained 1U and custom blade form factors. Due to certain limitations of such form factors (i.e. airflow, thermal solution height), it is very challenging to meet the thermal requirements of the processor. To mitigate these form factor constraints, Intel has developed a dual Thermal Profile specification, shown in Figure 2-10.

26

Quad-Core Intel® Xeon® Processor 5400 Series TMDG

Image 26
Contents Quad-Core Intel Xeon Processor 5400 Series Thermal/Mechanical Design GuidelinesQuad-Core Intel Xeon Processor 5400 Series Tmdg Contents Figures Preload Test Configuration Tables Reference Revision Description Date Number Initial release of the documentQuad-Core Intel Xeon Processor 5400 Series Tmdg References ObjectiveScope Term Description Definition of TermsTerms and Descriptions Sheet 1 Terms and Descriptions Sheet 2 TDPIntroduction Processor Mechanical Parameters Table Mechanical RequirementsProcessor Mechanical Parameters Parameter Minimum Maximum UnitQuad-Core Intel Xeon Processor 5400 Series Package Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design Quad-Core Intel Xeon Processor 5400 Series Considerations Processor Thermal Parameters and Features Thermal Control Circuit and TDPDigital Thermal Sensor Multiple Digital Thermal Sensor Operation Platform Environmental Control Interface PeciMultiple Core Special Considerations Heatpipe Orientation for Multiple Core Processors Thermal Monitor for Multiple Core ProductsPROCHOT#, THERMTRIP#, and FORCEPR# Processor Input Processor OutputProcessor Core Geometric Center Dimensions Feature DimensionThermal Profile Equation 2-1.y = ax + bTcontrol Definition Equation 2-2.TCONTROL= -TOFFSETTcontrol and Thermal Profile Interaction Thermal Profile B Performance Targets Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design 1U CEK, Thermal Profile B Parameter Maximum Unit2U+ CEK, Thermal Profile a 1U Alternative Heatsink Fan Fail GuidelinesSea-Level Characterizing Cooling Solution Performance Requirements Fan Speed ControlEquation 2-3.ΨCA= Tcase TLA / TDP Processor Thermal Characterization Parameter RelationshipsFan Speed Control, Tcontrol and DTS Relationship Condition FSC SchemeExample Equation 2-4.ΨCA= ΨCS + ΨSAEquation 2-5.ΨCA= Tcase TLA / TDP = 68 45 / 85 = 0.27 C/W Chassis Thermal Design ConsiderationsChassis Thermal Design Capabilities and Improvements Equation 2-6.ΨSA= ΨCA − ΨCS = 0.27 − 0.05 = 0.22 C/WHeatsink Design Considerations Heatsink SolutionsThermal/Mechanical Reference Design Considerations Thermal Interface Material SummaryAssembly Drawing Geometric EnvelopeStructural Considerations of CEK Thermal Solution Performance Characteristics 17 U+ CEK Heatsink Thermal PerformanceThermal Profile Adherence Equation 2-8.y = 0.187*X +=0.187* X +40 Equation 2-9.y = 0.246*X +1UCEKReference Solution Equation 2-10.y = 0.246*X +Components Overview Heatsink with Captive Screws and Standoffs22. Isometric View of the 2U+ CEK Heatsink Thermal Interface Material TIM CEK Heatsink Thermal Mechanical CharacteristicsRecommended Thermal Grease Dispense Weight Processor Minimum Maximum UnitsCEK Spring 24. CEK Spring Isometric ViewThermal/Mechanical Reference Design Description Min Typ Max Unit Steady Startup Fan Power SupplyFan Specifications Boxed 4-wire PWM/DTS Heatsink Solution Boxed Processor Contents Systems Considerations Associated with the Active CEKThermal/Mechanical Reference Design Component Overview Figure A-1. Isometric View of the 1U Alternative HeatsinkEquation A-1. y = 0.331*x + Thermal Solution Performance CharactericsThermal Profile Adherence = Processor power value W 1U Alternative Heatsink Thermal/Mechanical Design Table B-1. Mechanical Drawing List Drawing DescriptionFigure B-1 2U CEK Heatsink Sheet 1 Figure B-2 2U CEK Heatsink Sheet 2 Figure B-3 U CEK Heatsink Sheet 3 Figure B-4 2U CEK Heatsink Sheet 4 Figure B-5. CEK Spring Sheet 1 Figure B-6. CEK Spring Sheet 2 Figure B-7. CEK Spring Sheet 3 Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Figure B-14 U CEK Heatsink Sheet 1 Figure B-15 U CEK Heatsink Sheet 2 Figure B-16 U CEK Heatsink Sheet 3 Figure B-17 U CEK Heatsink Sheet 4 Figure B-18. Active CEK Thermal Solution Volumetric Sheet 1 Figure B-19. Active CEK Thermal Solution Volumetric Sheet 2 Figure B-20. Active CEK Thermal Solution Volumetric Sheet 3 Figure B-21 U Alternative Heatsink 1 Figure B-22 U Alternative Heatsink 2 Figure B-23 U Alternative Heatsink 3 Figure B-24 U Alternative Heatsink 4 Mechanical Drawings Heatsink Preparation OverviewTest Preparation Alternate Heatsink Sample Preparation Figure C-3. Preload Test Configuration Typical Test Equipment Test Procedure ExamplesTime-Zero, Room Temperature Preload Measurement Table C-1. Typical Test EquipmentPreload Degradation under Bake Conditions Heatsink Clip Load Methodology Safety Requirements Safety Requirements Intel Verification Criteria for the Reference Designs Environmental Reliability TestingStructural Reliability Testing Reference Heatsink Thermal VerificationTable E-1 Use Conditions Environment 2.2 Recommended Test SequencePost-Test Pass Criteria Recommended BIOS/Processor/Memory Test Procedures Material and Recycling RequirementsQuality and Reliability Requirements Intel Enabled Suppliers Supplier InformationAdditional Suppliers For 1U2U Heatsink Alternative CEK Copper Fin Alternative CEK Copper Fin Enabled Suppliers Information 100 Quad-Core Intel Xeon Processor 5400 Series Tmdg