1U Alternative Heatsink Thermal/Mechanical Design
A.2 Thermal Solution Performance Characterics
Figure A-2 shows the performance of the 1U alternative heatsink. This figure shows the thermal performance and the pressure drop through fins of the heatsink versus the airflow provided. The best-fit equations for these curves are also provided to make it easier for users to determine the desired value without any error associated with reading the graph.
Figure A-2. 1U Alternative Heatsink Thermal Performance
Table A-1. 1U Alternative Heatsink Thermal Mechanical Characteristics
Size | Height | Weight | Target Airflow | Mean Ψca | Standard | Pressure | |
Drop | |||||||
|
| Through Fins | Deviation Ψca | ||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
| (mm) [in.] | (kg) [lbs] | (m3/hr) [CFM] | (°C/W) | (°C/W) | (Pa) [in | |
|
|
|
|
|
| H2O] | |
1U | 27.00 | 0.24 [0.53] | 25.5 [15] | 0.305 | 0.0087 | 85 [0.34] | |
| [1.06] |
|
|
|
|
| |
|
|
|
|
|
|
|
A.3 Thermal Profile Adherence
The 1U alternative thermal solution is designed to meet the Thermal Profile for the
Equation A-1. y = 0.331*x + 40
where,
y = Processor TCASE value (°C)
54 |
|