Thermal/Mechanical Reference Design

Figure 2-20. 1U CEK Thermal Adherence to Quad-Core Intel® Xeon® Processor X5400 Series Thermal Profile B

 

70

TCASE_MAX_B@ TDP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermal Profile B

 

 

 

 

 

 

 

 

 

 

 

 

C)

 

 

 

 

 

Y= 0.221 * X+ 43.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1UCEKReference Solution

 

 

 

Temperature(

55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y=0.246 * X+ 40

 

 

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120

 

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

90

100

110

 

 

 

 

 

 

 

 

 

 

 

 

 

Power (W)

 

 

 

 

 

TDP

The 1U CEK Intel reference thermal solution is designed to meet the Thermal Profile specification for the Quad-Core Intel® Xeon® Processor E5400 Series. From Table 2-7the three-sigma (mean+3sigma) performance of the thermal solution is computed to be 0.246 °C/W and the processor local ambient temperature (TLA) for this thermal solution is 40 °C. Hence, the Thermal Profile equation for this thermal solution is calculated as:

Equation 2-10.y = 0.246*X + 40

where,

y = Processor TCASE value (°C) x = Processor power value (W)

Figure 2-21below shows the comparison of this reference thermal solution’s Thermal Profile to the Quad-Core Intel® Xeon® Processor E5400 Series Thermal Profile specification. The 1U CEK solution meets the Thermal Profile with 7.3°C margin at the upper end (TDP). By designing to Quad-Core Intel® Xeon® Processor E5400 Series Thermal Profile, it is ensured that no measurable performance loss due to TCC activation is observed under the given environmental conditions.

44

Quad-Core Intel® Xeon® Processor 5400 Series TMDG

Image 44
Contents Quad-Core Intel Xeon Processor 5400 Series Thermal/Mechanical Design GuidelinesQuad-Core Intel Xeon Processor 5400 Series Tmdg Contents Figures Preload Test Configuration Tables Reference Revision Description Date Number Initial release of the documentQuad-Core Intel Xeon Processor 5400 Series Tmdg References ObjectiveScope Term Description Definition of TermsTerms and Descriptions Sheet 1 Terms and Descriptions Sheet 2 TDPIntroduction Mechanical Requirements Processor Mechanical ParametersProcessor Mechanical Parameters Table Parameter Minimum Maximum UnitQuad-Core Intel Xeon Processor 5400 Series Package Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design Quad-Core Intel Xeon Processor 5400 Series Considerations Processor Thermal Parameters and Features Thermal Control Circuit and TDPDigital Thermal Sensor Multiple Digital Thermal Sensor Operation Platform Environmental Control Interface PeciMultiple Core Special Considerations Thermal Monitor for Multiple Core Products PROCHOT#, THERMTRIP#, and FORCEPR#Heatpipe Orientation for Multiple Core Processors Processor Input Processor OutputProcessor Core Geometric Center Dimensions Feature DimensionThermal Profile Equation 2-1.y = ax + bTcontrol Definition Equation 2-2.TCONTROL= -TOFFSETTcontrol and Thermal Profile Interaction Thermal Profile B Performance Targets Thermal/Mechanical Reference Design Thermal/Mechanical Reference Design 1U CEK, Thermal Profile B Parameter Maximum Unit2U+ CEK, Thermal Profile a 1U Alternative Heatsink Fan Fail GuidelinesSea-Level Characterizing Cooling Solution Performance Requirements Fan Speed ControlProcessor Thermal Characterization Parameter Relationships Fan Speed Control, Tcontrol and DTS RelationshipEquation 2-3.ΨCA= Tcase TLA / TDP Condition FSC SchemeExample Equation 2-4.ΨCA= ΨCS + ΨSAChassis Thermal Design Considerations Chassis Thermal Design Capabilities and ImprovementsEquation 2-5.ΨCA= Tcase TLA / TDP = 68 45 / 85 = 0.27 C/W Equation 2-6.ΨSA= ΨCA − ΨCS = 0.27 − 0.05 = 0.22 C/WHeatsink Design Considerations Heatsink SolutionsThermal/Mechanical Reference Design Considerations Thermal Interface Material SummaryAssembly Drawing Geometric EnvelopeStructural Considerations of CEK Thermal Solution Performance Characteristics 17 U+ CEK Heatsink Thermal PerformanceThermal Profile Adherence Equation 2-8.y = 0.187*X +=0.187* X +40 Equation 2-9.y = 0.246*X +1UCEKReference Solution Equation 2-10.y = 0.246*X +Components Overview Heatsink with Captive Screws and Standoffs22. Isometric View of the 2U+ CEK Heatsink CEK Heatsink Thermal Mechanical Characteristics Recommended Thermal Grease Dispense WeightThermal Interface Material TIM Processor Minimum Maximum UnitsCEK Spring 24. CEK Spring Isometric ViewThermal/Mechanical Reference Design Description Min Typ Max Unit Steady Startup Fan Power SupplyFan Specifications Boxed 4-wire PWM/DTS Heatsink Solution Boxed Processor Contents Systems Considerations Associated with the Active CEKThermal/Mechanical Reference Design Component Overview Figure A-1. Isometric View of the 1U Alternative HeatsinkEquation A-1. y = 0.331*x + Thermal Solution Performance CharactericsThermal Profile Adherence = Processor power value W 1U Alternative Heatsink Thermal/Mechanical Design Table B-1. Mechanical Drawing List Drawing DescriptionFigure B-1 2U CEK Heatsink Sheet 1 Figure B-2 2U CEK Heatsink Sheet 2 Figure B-3 U CEK Heatsink Sheet 3 Figure B-4 2U CEK Heatsink Sheet 4 Figure B-5. CEK Spring Sheet 1 Figure B-6. CEK Spring Sheet 2 Figure B-7. CEK Spring Sheet 3 Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Mechanical Drawings Figure B-14 U CEK Heatsink Sheet 1 Figure B-15 U CEK Heatsink Sheet 2 Figure B-16 U CEK Heatsink Sheet 3 Figure B-17 U CEK Heatsink Sheet 4 Figure B-18. Active CEK Thermal Solution Volumetric Sheet 1 Figure B-19. Active CEK Thermal Solution Volumetric Sheet 2 Figure B-20. Active CEK Thermal Solution Volumetric Sheet 3 Figure B-21 U Alternative Heatsink 1 Figure B-22 U Alternative Heatsink 2 Figure B-23 U Alternative Heatsink 3 Figure B-24 U Alternative Heatsink 4 Mechanical Drawings Heatsink Preparation OverviewTest Preparation Alternate Heatsink Sample Preparation Figure C-3. Preload Test Configuration Test Procedure Examples Time-Zero, Room Temperature Preload MeasurementTypical Test Equipment Table C-1. Typical Test EquipmentPreload Degradation under Bake Conditions Heatsink Clip Load Methodology Safety Requirements Safety Requirements Environmental Reliability Testing Structural Reliability TestingIntel Verification Criteria for the Reference Designs Reference Heatsink Thermal VerificationTable E-1 Use Conditions Environment 2.2 Recommended Test SequencePost-Test Pass Criteria Recommended BIOS/Processor/Memory Test Procedures Material and Recycling RequirementsQuality and Reliability Requirements Intel Enabled Suppliers Supplier InformationAdditional Suppliers For 1U2U Heatsink Alternative CEK Copper Fin Alternative CEK Copper Fin Enabled Suppliers Information 100 Quad-Core Intel Xeon Processor 5400 Series Tmdg