SMC Networks 5000 manual Section Operation

Page 39

Section 5

Operation

The purpose of the Auto-Setup module is to allow automatic adjustment of such press systems as air counterbalances, air cushions, air operated hydraulic overloads, and slide adjust systems to greatly reduce setup time for different jobs, and to help ensure that these systems are adjusted correctly for different jobs.

All operation of auto-setup functions, other than automatic adjustments to previously stored values when the OmniLink 5000 recalls a job, start from the Auto-Sets screen. This screen is displayed when the “AUTO SETS” softkey on the Main Menu or Press Control screen is pressed. The Auto-Sets screen shows all configured functions and allows their settings to be adjusted. Figure 5.1 shows an example Auto-Sets screen. Note that each configured function (slide adjust, counterbalance, cushion, or hydraulic overload) has its own box with name, settings, position or pressure, status, and fault.

Figure 5.1: Example Auto-Sets Screen

The main features of this screen are:

a)The module status gives the overall status of the auto setup module as a whole instead of the status of a single sub-system, such as a counterbalance. When the module is functioning properly, thus should read “All Conditions OK”. See section 6.1 for other diagnostic messages.

b)Each configured sub-system has a status. Under normal conditions, this status will read “At Pressure” for air-based sub-systems such as counterbalances that are within the tolerance setting of the set pressure. Slide sub-systems will read “In Position” when within the tolerance setting

April 17, 2000 Man ual Versio n 1.0

5.1

Image 39
Contents OmniLink Table of Contents April 17, 2000 Man ual Versio n Iii April 17, 2000 Man ual Versio n Section Introduction Counterbalance ControlCushion Control Hydraulic Overload Control Shut Height ControlParameter Entry and Access Control 1 Numeric Entries2 Text Entry April 17, 2000 Man ual Versio n Access Control 1 Key Only Mode2 Key or Password Mode 6.1 RUN/PROG Key Switch Operation 3 Password Only Mode4 Key and Password Mode 6 Access Control OperationExample Password Entry Sequence 6.2 Password System OperationApril 17, 2000 Man ual Versio n Installation Auto-Setup Module Installation April 17, 2000 Man ual Versio n Valve Systems Type B Valve ConfigurationCounterbalance Control Installation Type C Valve ConfigurationAuto-Counterbalance with Type a Integrated Valve 1 Counterbalance Pressure Transducer Mounting 3 Counterbalance System Wiring Cushion System Installation2 Counterbalance Air Valve System Mounting 3 Cushion System Wiring 1 Cushion Pressure Transducer Mounting2 Cushion Air Valve System Mounting Hydraulic Overload System Installation Slide Adjust System Installation1 Rotary Transducer Mounting 3 Linear Transducer Mounting 2 Rotary Slide Adjust Wiring4 Linear Transducer Slide Adjust Wiring Setting up the OmniLink 5000 for the Auto-Setup Module ConfigurationExample Air Configuration Screen Configuring the Auto-Setup boardAir Pressure HelpAir Slot Hardware DetectedDisplay Weight As Regulator settingMax. Die Weight Min. Die WeightMax. Trip Point Max. Cushion ForceMin. Cushion Force Display Force AsValve Type Fault TimeTolerance Transducer Types2 Configuring Slide Adjust Modules Slide Slot ShutheightShut Height Units Pulse Time Upper LimitLower Limit Pulse Distance2.1 Calibrating Linear Slide Adjust Systems Lock TimeSerious injury or death Or death 2.2 Calibrating Rotary Slide Adjust SystemsResolver Turns System may fail to calibrateApril 17, 2000 Man ual Versio n April 17, 2000 Man ual Versio n Section Operation April 17, 2000 Man ual Versio n Slide Adjust Operation SetpointActual Position MAN manual Fault1 Slide On, Manual, and Off Settings StatusApril 17, 2000 Man ual Versio n Pressure Set 4 Slide Fault and StatusDie Weight Set 3 Manual Slide Movement2 Pressure and Force Setpoints 1 Air System On, Manual, and Off SettingsPress Trip Set Actual PressureJob Storage and Recall Issues 3 Air System Fault and StatusApril 17, 2000 Man ual Versio n Main Module Messages Diagnostics Fault and Status MessagesMax. Press. Exceeded Pressure Switch LowUnable to Fill Unable to DumpSlide Adjust Fault Messages Slide Adjust Status Messages Moving Up Auto-AdjustingWaiting S/A Switch Min Position ReachedSection A.1 Example Counterbalance Configuration Section A.2 Example Cushion Configuration Section A.3 Example Hydraulic Overload Configuration April 17, 2000 Man ual Versio n Section A.4 Example Linear Slide Adjust Configuration April 17, 2000 Man ual Versio n Section A.5 Example Rotary Slide Adjust Configuration April 17, 2000 Man ual Versio n April 17, 2000 Man ual Versio n Figure B.1 Typical Counterbalance Wiring Diagram Appendix B Typical Wiring DiagramsFigure B.2 Typical Cushion Wiring Diagram Figure B.3 Conceptual Dual Resolver Mounting Figure B.4 Typical Amci Dual Resolver Wiring Diagram Figure B.5 Typical Gemco Dual Resolver Wiring Diagram Figure B.6 Conceptual Linear Transducer Mounting Figure B.7 Typical Gemco Linear Transducer Wiring April 17, 2000 Man ual Versio n Figure B.11 Typical Slide Air Motor Solenoid Wiring April 17, 2000 Man ual Versio n Figure C.1 Logic Module Firmware Chip Locations Appendix C Installation Of OmniLink 5000 FirmwareApril 17, 2000 Man ual Versio n Section D.2 Valve Type a Lockout Procedure Power is onMust be done even if a LOX valve is opened in since Section D.4 Valve Type C Lockout Procedure Section D.3 Valve Type B Lockout ProcedureApril 17, 2000 Man ual Versio n April 17, 2000 Man ual Versio n Section E.2 Shut height Calibration Sheets April 17, 2000 Man ual Versio n Section F.3 5000-10C Rotary Shut Height Control Board Section F.2 5000-10B Linear Shut Height Control Board

5000 specifications

SMC Networks 5000 is a robust and versatile networking solution designed to meet the demands of modern digital infrastructures. This device is a part of SMC Networks' extensive product lineup, which caters to both enterprise and small to medium-sized businesses. The SMC 5000 stands out due to its high performance, reliability, and advanced feature set.

One of the key features of the SMC Networks 5000 is its high-speed connectivity. It supports multiple Gigabit Ethernet ports, allowing for fast data transfer and seamless connectivity. This makes it ideal for environments where bandwidth is critical, such as in data centers, large office environments, and educational institutions. The device also includes advanced traffic management capabilities, ensuring efficient data flow and minimizing latency.

Another impressive characteristic of the SMC 5000 is its scalability. As organizations grow and their networking needs evolve, the SMC 5000 can adapt accordingly. It supports a modular design, allowing users to add or remove components based on their specific requirements. This flexibility enables businesses to optimize their network setup without the need for a complete overhaul.

Security is a top priority for SMC Networks, and the 5000 model incorporates advanced security features to protect sensitive data. With built-in firewalls, virtual private network (VPN) support, and robust encryption protocols, the device ensures that unauthorized access is prevented. This is particularly crucial in today’s digital landscape, where cyber threats are increasingly sophisticated.

In terms of management and monitoring, the SMC 5000 offers a user-friendly interface that simplifies network administration. Administrators can easily configure settings, monitor performance metrics, and troubleshoot issues through a centralized dashboard. This streamlines network management tasks and enhances overall efficiency.

The SMC Networks 5000 is also compatible with various networking technologies, including VLAN (Virtual Local Area Network) support, QoS (Quality of Service) features, and IPv6 readiness. These technologies contribute to a more efficient network setup and pave the way for future-proofing as networking standards evolve.

Overall, the SMC Networks 5000 is a reliable and powerful networking solution that provides the performance, security, and scalability necessary for today's demanding network environments. Its combination of advanced features and user-friendly management options makes it an excellent choice for businesses looking to enhance their networking infrastructure. With SMC Networks 5000, organizations can ensure seamless connectivity while effectively managing their growing digital demands.