5. DISPLAY AND KEYPAD

Operator interaction with the oxygen transmitter is done through a graphical display and 8 keys on the front of the case. The five LED indicators are used to show the status of the transmitter and to alert the operator of any errors.

Each of the keys has a dual function;

The BLACK text printed on the key is the function while the transmitter is in the RUN mode

The WHITE text printed on the key is the function in one of the three configuring menus, (SETUP, COMMISSIONING and CALIBRATION)

The menu driven modes are accessed by pressing, and in some cases holding down, the SETUP key (see chapters 6, 7 and 8 for details of these modes). The transmitter will return to the RUN mode when the SETUP key is pressed again, or if 60 seconds has elapsed since the last key was pressed.

5.1 Graphical Display

In RUN mode the 9060Z shows the first oxygen probe measurement in large characters at the top of the display and a user selectable lower line in smaller characters below. Other items on the display include the activity heartbeat indicator in the top right corner, a row of single letter action indicators in the bottom left corner and the current time in the bottom right corner.

In SETUP mode the RUN display is replaced with a menu driven interface. All other functions of the transmitter (reading, calculating and transmitting etc) aside from the keypad and display will continue to operate as normal.

27

Image 27
Contents Teledyne Analytical Instruments Model 9060Z Manual Keypad Purge Forcing a Cold Start Resetting the Calibration FactorsEmail asktai@teledyne.com Important Notice Regarding 9060 Probe Option ‐ FIL‐3 Important Notices Introduction 9060Z TransmitterSeries 9060H Oxygen Probes & Sensors Model 9060Z Manual Power Temperature accuracyOutput load Alarm relays Alarm relay contacts9060H 9060UL/UH Application Temperature RangeHead Temperature Connection WeightHeated probes‐temperature range 0‐900C 1650F Model 9060Z Manual Range of outputs Function Minimum MaximumInstallation and Commissioning Installing a 9060H Oxygen ProbeMounting the Transmitter Oxygen Probe Mounting Electrical Connections Installing the Auxiliary Thermocouple4A Shield Connections 4B Earth Connection PEModel 9060Z Manual Model 9060Z Manual Connecting AN Oxygen Probe Cable Heater Interlock RelaysHeater Supply Interlock Connection for Heated Probes Model 9060Z Manual Connecting the Automatic Purge and Calibration Check System Connecting the Auxiliary Thermocouple OptionalConnecting the Output Channels Connecting the AlarmsConnecting the Transmitter to a Modbus Network Connecting Reference AIRFor more details see Appendix Onnecting PowerCommissioning ‐ RUN Mode Probe or Sensor CalibrationFilter Purging Calibration GAS CheckDust in the Flue GAS Stratification Connecting a Pressure TransducerGraphical Display Display and KeypadKeypad Keypad in RUN modeKey text RUN mode White text Setup mode Black text Oxygen Display UnitsKeypad in Setup / Commissioning / Calibration modes Probe impedance key Function up and Function down keysOption up and Option down keys Enter keyFunction name Range Setup ModeFunction Summary Table Changing OptionsSetup Mode Functions Probe 1 OffsetLower Line Items Process Alarms Oxygen Display UnitsDamping Factor Commissioning Mode Model 9060Z Manual Commissioning Mode Functions Model 9060Z Manual Solenoid 1 & 2 Operation Temperature UnitsFlue Pressure Units and Value Calibration Freezes OutputsCommon Alarm Relay Function Oxygen Content Calibration Gas 1Maximum Calibration Gas 1 & 2 Positive / Negative Error Alarm Relay 1, 2 and 3 FunctionFunction Options Operation of the Alarm Relays when an Alarm is AcceptedSelecting the Correct Fuel Reference Air Pump OptionsCommunications Port Options Alarm Log ClearingMenu Function name Range Calibration ModeReference Voltages Calibration Mode FunctionsHeater SSR Fault Correction Common Alarms AlarmsModel 9060Z Manual Selectable Process Alarms Alarm Relay Options Calibration Summary Instrument CalibrationCold Start Probe CalibrationGAS Calibration Check and Purge Calibration GASFunction # Function Description Options Software Upgrades Troubleshooting Detailed Fault AnalysisFirst Approach Replacement Parts MaintenanceTransmitter Maintenance CleaningAuxiliary Thermocouple IndexTroubleshooting Is the S/C atom ratio in the fuel Is the H/C atom ratio in the fuelIs the O/C atom ratio in the fuel Is the N/C atom ratio in the fuelProbe EMF @ 720C 1320F Appendix 2, Probe EMF TablesZirconia Oxygen Sensor Output mV Probe Type 9060H, Sensor Probe EMFZirconia Oxygen Probe Output mV Probe Type 9060UL/UH 33.8 13.120.7 26.2Modbus Protocol Serial ConfigurationModel 9060Z Manual Model 9060Z Manual Model 9060Z Manual Model 9060Z Manual Model 9060Z Manual 0x04 0x41 Special Instruction Function0x02 0x03