Kohler 1199249-2-A manual Troubleshooting

Page 20

Troubleshooting (cont.)

Symptoms

Probable Causes

Recommended Action

7.

Blower motor runs but no

A.

Blower air inlet is blocked.

A.

Clean blower air inlet.

 

air bubbles are formed.

B.

Airjets are clogged.

B.

Use a small between-the-teeth

 

 

 

 

 

dental brush and white vinegar.

 

 

 

 

 

Dip the brush in the vinegar, brush

 

 

 

 

 

the hole, rinse the brush in clean

 

 

 

 

 

water, and then use the wet rinsed

 

 

 

 

 

brush to rinse the hole.

 

 

C.

Check valve does not work.

C.

Replace the check valve.

 

 

D.

Blower motor does not work.

D.

Replace the blower motor.

 

 

E.

Control does not work.

E.

Replace the control.

8.

Blower motor operates,

A.

Blower air inlet is blocked.

A.

Clear blower air inlet.

 

air bubbles are formed,

B.

Loose, disconnected, or

B.

Check wiring for proper

 

zone controls work, but

 

damaged wiring harness.

 

connections. Replace the wiring

 

variable speed feature

 

 

 

harness if necessary.

 

does not work.

 

 

 

 

 

C.

User keypad does not work.

C.

Replace the user keypad.

 

 

 

 

D.

Blower motor does not work.

D.

Replace the blower motor.

 

 

E.

Control does not work.

E.

Replace the control.

9.

Blower motor won’t turn

A.

User keypad does not work.

A.

Replace the user keypad.

 

off when the Power icon

B.

Loose, disconnected, or

B.

Check wiring for proper

 

on user keypad is

 

damaged wiring harness.

 

connections. Replace the wiring

 

pressed.

 

 

 

harness if necessary.

 

 

C.

Control does not work.

C.

Replace the control.

10.

A zone does not produce

A.

Zone is not selected.

A.

Select the zone according to the

 

air bubbles but another

 

 

 

instructions in the Operating

 

zone operates normally.

 

 

 

Instructionssection.

 

 

B.

Butterfly valve does not work.

B.

Replace the butterfly valve.

 

 

C.

Loose, disconnected, or

C.

Check wiring for proper

 

 

 

damaged wiring harness.

 

connections. Replace the wiring

 

 

 

 

 

harness if necessary.

 

 

D. User keypad does not work.

D. Replace the user keypad.

 

 

E.

Control does not work.

E.

Replace the control.

11.

Surge mode does not

A.

User keypad does not work.

A.

Replace the user keypad.

 

work.

 

 

 

 

 

 

B.

Control does not work.

B.

Replace the control.

12.

Water spillage or damage

A.

Drain or overflow leaking.

A.

Repair or replace the drain

 

observed under the bath.

 

 

 

assembly according to the

 

 

 

 

 

manufacturer’s instructions.

 

 

B.

Wall, deck, and/or shower door

B.

Apply silicone sealant at the seams

 

 

 

is improperly sealed.

 

between the bath and the wall,

 

 

 

 

 

deck, or door.

 

 

C.

Cracked piping or air channels.

C.

Refer to the manufacturer.

13.

Bath does not purge

A.

Level sensor wires are

A.

Connect the level sensor wires.

 

automatically.

 

disconnected.

 

 

 

 

 

 

 

Chromatherapy (if equipped)

 

 

 

 

 

 

 

Symptoms

Probable Causes

Recommended Action

14.

Chromatherapy lights do

A.

Loose, disconnected or damaged

A.

Check wiring for proper

 

not work.

 

wiring/connections.

 

connections. Replace wiring if

 

 

 

 

 

necessary.

 

 

B.

Control does not work.

B.

Replace control.

15.

Chromatherapy does not

A.

Chromatherapy harness

A.

Replace the chromatherapy harness

 

cycle.

 

assembly does not work.

 

assembly.

 

 

 

 

 

 

1199249-2-A

20

Kohler Co.

Image 20
Contents Installation and Care Guide Product Notices Product InformationElectrical Requirements Features Tools and MaterialsPrepare the Blower Remote Site Product InformationPrepare the Blower Remote Site Prepare the Site AlcoveCut the Banding Straps Install the BathInstall the Plumbing Typical Wiring Connection for North America Make Electrical Connections StandardPrepare the Site Disconnect the Blower Motor RemoteRemove the Blower Motor and Check Valve Mount the Blower Motor and Check Valve Remote Manufacturer’s instructionsRoute the Power Cable Prepare the Blower for Remote InstallationConnect the New Power Cable at the Blower Motor Terminate the Cable at the Blower RemoteInstall the Blower Cord at the Control Remote Install the Second Junction Box on the ControlReconnect the Blower Motor Power Cord Reconnect the Blower New Power CableMake Power Connections Remote Complete the InstallationRemote Blower Test Run the BathComplete the Installation Finish the Installation Clean-up After InstallationImportant Safety Instructions Initiating a Manual Purge Cycle when desired Operating InstructionsStarting the Unit Selecting Air Flow ModesCare and Cleaning WarrantyCleaning Your User Keypad and Remote Control Maintaining the AirjetsWarranty For MexicoTroubleshooting Exceptions and RestrictionsTroubleshooting Symptoms Probable Causes Recommended ActionTroubleshooting Installations électriques requises Information sur le produitPréparer le souffleur Installation à distance Outils et matériauxCaractéristiques Information sur le produitPréparer le souffleur Installation à distance Encastrer par le dessus Préparer le siteAlcôve Couper les sangles de retenue Installer la baignoireInstaller la plomberie Effectuer les connexions électriques Standard Câblage typique pour lAmérique du NordPréparer le site Déconnecter le moteur du souffleur À distanceRetirer le moteur du souffleur et le clapet de non-retour Selon les instructions du fabricant Acheminer le câble d’alimentation Préparer le souffleur pour une Installation à distanceFinir le câble au souffleur À distance Finir le câble au souffleur À distance Installer le cordon au niveau de la commande À distance Installer le deuxième boîtier de jonction sur la commande60 Hz 50 Hz Depuis le contrôle Reconnecter le cordon d’alimentation du moteur du souffleurTerminer l’installation Effectuer les connexions électriques À distanceMoteur-souffleur à distance Tester le fonctionnement de la baignoireTerminer l’installation Nettoyer après l’installationInstructions Importantes sur la sécurité 1199249-2-A Français-14 Kohler CoInstructions d’utilisation Démarrer l’appareilSélectionner les modes de débit d’air Arrêter la baignoireMaintenance des jets d’air Nettoyer le clavier utilisateur et la télécommandeEntretien et nettoyage GarantieGarantie Limitée D’UN AN GarantieDépannage Symptômes Causes probables Action recommandée Dépannage1199249-2-A Français-20 Kohler Co Kohler Co Français-21 1199249-2-A Información sobre el producto Requisitos eléctricosHerramientas y materiales Prepare el soplador lugar remotoAvisos sobre el producto CaracterísticasPrepare el soplador lugar remoto De sobreponer Prepare el sitioEncajonado entre tres paredes Instale la plomería Instale la bañeraCorte las cintas Realice las conexiones eléctricas Estándar Conexión de cableado típica para NorteaméricaPrepare el sitio Desconecte el motor soplador RemotoRetire el motor soplador y la válvula de retención Monte el motor soplador y la válvula de retención Remoto Del fabricanteTermine el cable en el soplador Remoto Tienda el cable eléctricoPrepare el soplador para la instalación remota Conecte el cable de eléctrico nuevo al motor sopladorTermine el cable en el soplador Remoto Instale el cable del soplador al control Remoto 60 Hz 50 Hz Del controlInstale la segunda caja de empalmes en el control Vuelva a conectar el cable eléctrico del motor sopladorRealice las conexiones eléctricas Remoto Termine la instalaciónSoplador remoto Pruebe el funcionamiento de la bañeraLimpieza después de la instalación Termine la instalaciónAcabe la instalación Instrucciones importantes de seguridad Kohler Co Español-14 1199249-2-AInstrucciones de funcionamiento Puesta en marcha de la unidadSelección de los modos de flujo de aire Pare el funcionamiento de la bañeraCuidado y limpieza GarantíaInstrucciones de funcionamiento Mantenimiento de los jets de aireGarantía Limitada DE UN AÑO GarantíaGuía para resolver problemas Para MéxicoGuía para resolver problemas Síntomas Causas probables Acción recomendadaKohler Co Español-20 1199249-2-A 1199249-2-A Español-21 Kohler Co 1199249-2-A Kohler Co