Product Information (cont.)
Features
Factory assembled components include a blower motor, air harness, control, check valve, butterfly valves, chromatherapy lights (if provided), electrical harnesses, and an illuminated user keypad. Other than power wiring and plumbing, no assembly is required.
Tools and Materials
Silicone Sealant | Measuring Tape | Pencil | Tin Snips | Level |
Plus:
• Conventional woodworking tools and materials
• Drop cloth
• Metal shims
• 2x4s
Safety Glasses | Pipe Wrench |
Prepare the Blower (Remote Site)
NOTICE: The blower motor and the check valve must be relocated together. Do not relocate one without the other.
NOTE: This bath can be installed as received or with the blower motor and check valve relocated to another location. Refer to the appropriate sections throughout this manual for instructions related to your particular installation. Read this section before relocating your blower.
Relocate the blower and check valve as close as possible to the bath to maximize performance. Do not relocate the blower and check valve more than 15’ (4.5 m) from the bath.
•Position the blower
•Use
•The piping installation must meet the requirements of local plumbing or building codes. Ensure that the installation does not reduce the fire rating of any walls. Piping must be supported at intervals along the length in accordance with local codes.
•Ensure that the blower motor location is clean and free of dust or debris.
•Install an access panel for blower motor maintenance.
•The 18 AWG minimum power cable to the blower motor must meet the requirements of all applicable electrical or building codes. Ensure that the installation does not reduce the fire rating of any walls.
•The power cord must be supported at intervals along its length in accordance with local codes. Power cords must not rest on surfaces or floors that are subject to flooding.
•All material needed for the relocation must be supplied by the installer.
Additional tools and materials you will need:
Kohler Co. | 3 |