Ingersoll-Rand 100-200 HP/75-160 KW, 125-200 HP/90-160 KW Main Menu, Operator Setpoints

Page 22

3.4 MAIN MENU

 

 

 

 

 

 

 

 

 

 

 

-MAIN MENU-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operator Setpoints

 

 

 

1 0 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

 

 

 

P S I

 

 

 

 

 

 

 

 

 

 

 

Sensor Calibration

 

 

 

 

 

 

 

 

 

 

 

 

 

Ready To Start

 

 

Alarm History

 

 

 

 

 

 

 

 

 

 

 

Clock Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

 

 

 

 

 

 

 

 

 

SELECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The MAIN MENU screen is the point from which various operator functions can be accessed. Refer to the reference diagram in Figure 3.2.1.

Each of the functions can be chosen by using the up and down arrows to highlight it on the screen.

The controller will go to the highlighted function if the SELECT button is pressed or will return to the CURRENT STATUS screen if the STATUS button is pressed.

3.5 OPERATOR SETPOINTS

1 0 0 P S I

Ready To Start

-OPERATOR SETPOINTS-

Offline Pressure

103PSI

Online Pressure 93 PSI

STATUS

MAIN MENU

SELECT

Setpoints are user-adjustable variables in the controller logic that can be set using the OPERATOR SETPOINTS screen.

The name and value of each of the setpoints listed below can be seen on the screen by moving the list up and down using the arrow buttons.

OPERATOR SETPOINTS

RANGE

STEP

UNIT

Lead/Lag

Lead or Lag

---

---

Offline Pressure

75 to RATED +3

1

PSIG

Online Pressure

65 to OFFLINE - 10

1

PSIG

Lag Offset

0 to 45

1

PSIG

Mode of Operation

MOD/ACS, ON/OFF LINE, ---

---

 

MODULATION ONLY

 

 

Max Modulation Pressure

Online + 10 to Offline + 7

1

PSIG

Stop Delay Time

10 to 60

1

SEC

Star-Delta Time*

5 to 20

1

SEC

(Screen) Contrast

0 to 10

1

---

* Does not apply to automatic across the line starters.

Setpoints associated with options are described in the OPTIONS Section 3.6.

A setpoint’s value can be changed by first highlighting the item and its value and pressing the SELECT button to highlight just the value. When the value line is highlighted by itself, the value can be adjusted using the up and down arrow buttons. The CANCEL and SET buttons appear at this time. Press the SET button to enter the new value, or press the CANCEL button to return to the value of the setpoint prior to using the arrows. The displayed value will flash twice to indicate it has been entered into the setpoint, and the pair of setpoint item and value display lines will again be highlighted together.

Operator set points can be exited by pressing the STATUS or MAIN MENU buttons. If no buttons are pressed within 30 seconds, the display will return to the CURRENT STATUS screen.

20

Image 22
Contents Phone CCN 80440415 REV B Form Apdd 738BAIR Compressor Group Bonded Warranty & Registered Start UP Rotary Screw AIR Compressor This unit was purchased fromTable of Contents Safety and Warnings Safety Shutdown Lift Here DecalsDecals Viewed From RearCompressor Package Data Unpacking and Handling InspectionIngersoll-Rand Company Davidson, North Carolina ToolsNever elevate the compressor unit VentilationFoundation Requirements Performance will be affectedDo not use the compressor to support the discharge pipe Moisture Content of Compressed AIRPiping Discharge Piping with Aftercooler ROTARY-RECIP in ParallelElectrical Installation Rotary TWO Compressor SystemRotation Check Drive MotorFAN Motor Electrical InstallationHasp Lever TAG KEY Lock Intellisys Operating InstructionsOutdoor Sheltered Installation 1 Typical Outdoor Sheltered Installation Intellisys Intellisys ControllerStart Power on LightIntellisys Controls Emergency Stop StopCurrent Status Display ScreenCurrent Status Items Panel Flow Figure DiagramOperator IntellisysMain Menu Operator SetpointsOptions Options Items Range Step UnitOptions Sensor Calibration Alarm HistorySensor Calibration Items Alarm History Items Clock FunctionsIntegral Sequencing Integral Sequencing Range Step UnitStatus Main Menu Reset Alarms Alarm Main MenuPage Maintenance Procedures Maintenance ScheduleMaintenance Records Number of Running HOURS, Whichever Occurs First200 HP/132-160 KW Requires 2 Elements Inlet AIR FilterCoolant Filter ElementsCoolant Drain CoolantItems Required Hot coolant can cause severe injuryCoolant ProcedureSeparator Tank Scavenge SCREEN/ORIFICE Tools Required Recommended Bolt Tightening Cross Pattern Coolant Separator ElementTank cover bolt torque values 125/200 HPCooler Cores Cleaning Coolant CoolersAftercooler Aftercooler CleaningAftercooler Motor Lubrication Relubrication amount Lubricant Amount Motor Frame Size GramsRecommended Motor Grease Motor Bearing Maintenance Stored UnitsMotor Lubrication Hazardous voltage. Can cause severe injury or deathTools Long Term Storage GeneralIntellisys Removal Controller RemovalCoolant Hoses InstallationCoolant Sampling Procedure RemovalCoolant Cooler AIR Cooled Compressors Design TemperaturesGeneral System Information Cooling FAN MotorOperation Compressed AIR System The air system is composedCOOLANT/AIR Separation System Electrical SystemCapacity Control STAR-DELTA Type StarterStepper Motor Inlet Control Automatic Unloaded StartAutomatic START/STOP Control Modulation onlyFirst Some Examples of Operation SecondExample Remote START/STOP Troubleshooting Chart Troubleshooting Chart LOW Ambient Power Outage Restart OptionSequencer Separator DELTA-P SolenoidRemote LOAD/UNLOAD ModbusElectrical Schematic Star Delta Reference DrawingsPage Foundation Plan 125-150 HP/90-110KW Aircooled Single Stage Foundation Plan 125-150 HP/90-110 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage REV C REV C Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan Aircooled 100-150 HP/75-110 KW TWO StageFoundation Plan Aircooled 100-150 HP/75-110 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED Foundation Plan -WATERCOOLED 100-150 HP/75-110 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Flow Schematic Aircooled Single Stage Page Flow Schematic Watercooled 90F 32C Single Stage Page Flow Schematic Watercooled 115F 46 Single Stage Page Flow Schematic AIR-COOLED TWO Stage Page Flow Schematic Watercooled 90F 32C TWO Stage Page Flow Schematic Watercooled 115F 46C TWO Stage Page Typical System Flow Diagram Typical System Flow DiagramsTypical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Fouling ScaleCorrosion Parameter Concentration Frequency of AnalysisPage Hardness ppm Temperature FTotal dissolved solids ppm Alkalinity ppmMaintenance Record Maintenance Record Maintenance Record Maintenance Record