Ingersoll-Rand 100-200 HP/75-160 KW, 125-200 HP/90-160 KW technical manual Troubleshooting Chart

Page 48

6.0 TROUBLESHOOTING CHART

TROUBLE

CAUSE &/OR DISPLAY

WHAT TO DO

 

 

 

Compressor fails to start.

110/120V control voltage not available,

Check fuses. Check transformer and wiring connections.

 

CONTROL POWER LOSS

 

 

 

STARTER FAULT

Inspect contactors.

 

EMERGENCY STOP

Rotate emergency stop button to disengage, and press reset button

 

 

 

twice.

 

MAIN (OR FAN) MOTOR OVERLOAD

Manually reset main or fan motor overload relay, and press reset

 

 

 

button twice.

 

SENSOR FAILURE XXXX

Check for defective sensor, bad sensor connection, or broken

 

 

 

sensor wires.

 

CHECK INLET CTRL SYS.

Call factory representative.

 

Intellisys 24 VAC control voltage not

Check fuses.

 

available

 

 

 

Display panel and power on light does

Check wiring. Verify 24 VAC is within voltage tolerance (± 15%).

 

not illuminate.

 

 

Compressor shuts down.

HIGH AIREND DISCH TEMP.

NOTE: If a shutdown

 

occurs, press the Status

LOW UNLOAD SUMP PRESS.

button once to activate

 

the display table. Using

 

the adjacent up and

CHECK INLET CTRL SYS.

down arrows, the values

 

displayed will be those

SENSOR FAILURE XXXX

immediately preceding

 

shutdown. Use these

 

values when

CHECK MOTOR ROTATION

troubleshooting a problem.

MAIN MOTOR OVERLOAD

FAN MOTOR OVERLOAD

STARTER FAULT

CHECK SET POINTS

CONTROL POWER LOSS

STEPPER LIMIT SWITCH

REMOTE STOP FAILURE

REMOTE START FAILURE

EMERGENCY STOP

LOW SUMP AIR PRESS

CHECK INLET CONTROL

Ensure that installation area has adequate ventilation.

Ensure that cooling fan is operating. If not, reset circuit breaker inside starter box.

Check coolant level. Add if required.

Cooler cores dirty. Clean coolers.

Check for air leak from tank or blowdown piping.

Check for slipping or broken stepper motor coupling.

Call factory representative.

Check for defective sensor, bad sensor connection, or broken sensor wires.

Interchange any two line connections (L1, L2, L3) at the starter.

Check for loose wires.

Check supply voltage.

Check heater setting.

Check for loose wires.

Check supply voltage.

Check heater setting.

Check for dirty cooler cores.

Inspect starter connectors.

Check for loose wires.

Reset to clear.

Calibrate sensors.

Check all set points.

Check fuses. Check transformer and wiring connections.

Call factory representative.

Check Remote Stop Switch and wiring.

Check Remote Start Switch and wiring.

Disengage emergency stop button.

Press reset button twice.

See LOW UNLOAD SUMP PRESS

Check for air leaks at inlet valve.

Check for slipping or broken stepper motor coupling.

46

Image 48
Contents Phone CCN 80440415 REV B Form Apdd 738BAIR Compressor Group Bonded Warranty & Registered Start UP Rotary Screw AIR Compressor This unit was purchased fromTable of Contents Safety and Warnings Safety Shutdown Lift Here DecalsDecals Viewed From RearCompressor Package Data Inspection Ingersoll-Rand Company Davidson, North CarolinaUnpacking and Handling ToolsVentilation Foundation RequirementsNever elevate the compressor unit Performance will be affectedMoisture Content of Compressed AIR PipingDo not use the compressor to support the discharge pipe Discharge Piping with Aftercooler ROTARY-RECIP in ParallelElectrical Installation Rotary TWO Compressor SystemRotation Check Drive MotorElectrical Installation Hasp Lever TAG KEY LockFAN Motor Intellisys Operating InstructionsOutdoor Sheltered Installation 1 Typical Outdoor Sheltered Installation Intellisys Intellisys ControllerPower on Light Intellisys Controls Emergency StopStart StopDisplay Screen Current StatusCurrent Status Items Diagram OperatorPanel Flow Figure IntellisysMain Menu Operator SetpointsOptions Options Items Range Step UnitOptions Alarm History Sensor CalibrationSensor Calibration Items Alarm History Items Clock FunctionsIntegral Sequencing Integral Sequencing Range Step UnitStatus Main Menu Reset Alarms Alarm Main MenuPage Maintenance Schedule Maintenance RecordsMaintenance Procedures Number of Running HOURS, Whichever Occurs FirstInlet AIR Filter Coolant Filter200 HP/132-160 KW Requires 2 Elements ElementsCoolant Items RequiredCoolant Drain Hot coolant can cause severe injuryProcedure CoolantSeparator Tank Scavenge SCREEN/ORIFICE Tools Required Coolant Separator Element Tank cover bolt torque valuesRecommended Bolt Tightening Cross Pattern 125/200 HPCooler Cores Cleaning Coolant CoolersAftercooler Cleaning AftercoolerAftercooler Motor Lubrication Relubrication amount Lubricant Amount Motor Frame Size GramsMotor Bearing Maintenance Stored Units Motor LubricationRecommended Motor Grease Hazardous voltage. Can cause severe injury or deathLong Term Storage General Intellisys RemovalTools Controller RemovalInstallation Coolant Sampling ProcedureCoolant Hoses RemovalAIR Cooled Compressors Design Temperatures General System InformationCoolant Cooler Cooling FAN MotorCompressed AIR System The air system is composed COOLANT/AIR Separation SystemOperation Electrical SystemSTAR-DELTA Type Starter Stepper Motor Inlet ControlCapacity Control Automatic Unloaded StartModulation only Automatic START/STOP ControlFirst Second Some Examples of OperationExample Remote START/STOP Troubleshooting Chart Troubleshooting Chart Power Outage Restart Option SequencerLOW Ambient Separator DELTA-P SolenoidRemote LOAD/UNLOAD ModbusElectrical Schematic Star Delta Reference DrawingsPage Foundation Plan 125-150 HP/90-110KW Aircooled Single Stage Foundation Plan 125-150 HP/90-110 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage REV C REV C Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan Aircooled 100-150 HP/75-110 KW TWO StageFoundation Plan Aircooled 100-150 HP/75-110 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED Foundation Plan -WATERCOOLED 100-150 HP/75-110 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Flow Schematic Aircooled Single Stage Page Flow Schematic Watercooled 90F 32C Single Stage Page Flow Schematic Watercooled 115F 46 Single Stage Page Flow Schematic AIR-COOLED TWO Stage Page Flow Schematic Watercooled 90F 32C TWO Stage Page Flow Schematic Watercooled 115F 46C TWO Stage Page Typical System Flow Diagram Typical System Flow DiagramsTypical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Scale CorrosionFouling Parameter Concentration Frequency of AnalysisPage Temperature F Total dissolved solids ppmHardness ppm Alkalinity ppmMaintenance Record Maintenance Record Maintenance Record Maintenance Record