Ingersoll-Rand 100-200 HP/75-160 KW, 125-200 HP/90-160 KW technical manual Table of Contents

Page 4

TABLE OF CONTENTS

0.0SAFETY AND WARNINGS

0.1safety instructions

0.2safety precautions

0.3decals

1.0RECEIPT OF EQUIPMENT

1.1inspection

1.2unpacking and handling

1.3tools

2.0INSTALLATION

2.1ventilation

2.2foundation requirements

2.3piping

2.4electrical installation

2.5outdoor sheltered

3.0INTELLISYS®

3.1intellisys controls

3.2display screen

3.3current status

3.4main menu

3.5operator setpoints

3.6options

3.7sensor calibration

3.8alarm history

3.9warnings

3.10alarms

4.0SCHEDULED PREVENTATIVE MAINTENANCE

4.1maintenance schedule

4.2maintenance records

4.3maintenance procedures

4.4inlet air filter

4.5coolant filter

4.6coolant

4.7separator tank scavenge screen/orifice

4.8coolant separator element

4.9cooler cores (cleaning)

4.10motor lubrication

4.11long term storage

4.12coolant/lubricant changeout

4.13intellisys removal

4.14coolant hoses

4.15fluid and vibration monitoring

4.16coolant sampling procedure

5.0SYSTEMS

5.1general system information

5.2air cooled compressors

5.3coolant system

5.4compressed air system

5.5coolant/air separation system

5.6electrical system

5.7stepper motor inlet control

5.8capacity control system

5.9automatic start/stop control

5.10remote start/sto

6.0TROUBLESHOOTING

2

7.0OPTIONS

7.1power outage restart option

7.2sequencer

7.3low ambient

7.4separator delta-p solenoid

7.5separator delta-p sensor

7.6high dust filter

7.7lead/lag cycle length

7.8schedule start/stop

7.9remote load/unload

7.10modbus

7.11integral sequencing

8.0REFERENCE DRAWINGS

8.1electrical schematic, star delta

8.2foundation plan, 125/150 HP, A/C - Single Stage

8.3foundation plan, 200 HP, A/C - Single Stage

8.4foundation plan, 125/150 HP, W/C - Single Stage

8.5foundation plan, 200 HP, W/C - Single Stage

8.6foundation plan, 125/150 HP, A/C - Two Stage

8.7foundation plan, 200 HP, A/C - Two Stage

8.8foundation plan, 125/150 HP, W/C - Two Stage

8.9foundation plan, 200 HP, W/C - Two Stage

8.10flow schematic, A/C - Single Stage

8.11flow schematic, W/C-90°F (32°C) - Single Stage

8.12flow schematic, W/C-115°F (46°C) - Single Stage

8.13flow schematic, A/C - Two Stage

8.14flow schematic, W/C-90°F (32°C) - Two Stage

8.15flow schematic, W/C-115°F (46°C) - Two Stage

8.16typical system flow diagrams

9.0WATER QUALITY RECOMMENDATIONS

10.0MAINTENANCE RECORD

Weight

See foundation plan, Section 8.0

Cooling Air Flow

See foundation plan, Section 8.0

Ambient Temperature Limits

35°F to 115°F

...........................................................................

((2°C to 46°C)

Coolant

Factory Filled SSR Ultra Coolant

Coolant Change

8000 hours or two years

............................................................

whichever comes first

Coolant Capacity

 

 

125/200 HP (90-160 KW) -

 

Single Stage

23.0 gallons (87.4 liters)

100 HP (75 KW) -

 

 

Two Stage

22.0 gallons (83.3 liters)

125-200 HP (90-160 KW) -

 

Two Stage

30.0 gallons (113.6 liters)

Discharge Temperature Limit

228°F (109°C)

Power Inlet Wiring

Recommended conduit:

............................metallic flexible Greenfield, or equivalent

Tools

U.S. standard and metric

...................................

are required to perform maintenance

Image 4
Contents Phone CCN 80440415 REV B Form Apdd 738BAIR Compressor Group Bonded Warranty & Registered Start UP Rotary Screw AIR Compressor This unit was purchased fromTable of Contents Safety and Warnings Safety Shutdown Lift Here DecalsDecals Viewed From RearCompressor Package Data Inspection Ingersoll-Rand Company Davidson, North CarolinaUnpacking and Handling ToolsVentilation Foundation RequirementsNever elevate the compressor unit Performance will be affectedMoisture Content of Compressed AIR PipingDo not use the compressor to support the discharge pipe Discharge Piping with Aftercooler ROTARY-RECIP in ParallelElectrical Installation Rotary TWO Compressor SystemRotation Check Drive MotorElectrical Installation Hasp Lever TAG KEY LockFAN Motor Intellisys Operating InstructionsOutdoor Sheltered Installation 1 Typical Outdoor Sheltered Installation Intellisys Intellisys ControllerPower on Light Intellisys Controls Emergency StopStart StopCurrent Status Display ScreenCurrent Status Items Diagram OperatorPanel Flow Figure IntellisysMain Menu Operator SetpointsOptions Options Items Range Step UnitOptions Sensor Calibration Alarm HistorySensor Calibration Items Alarm History Items Clock FunctionsIntegral Sequencing Integral Sequencing Range Step UnitStatus Main Menu Reset Alarms Alarm Main MenuPage Maintenance Schedule Maintenance RecordsMaintenance Procedures Number of Running HOURS, Whichever Occurs FirstInlet AIR Filter Coolant Filter200 HP/132-160 KW Requires 2 Elements ElementsCoolant Items RequiredCoolant Drain Hot coolant can cause severe injuryCoolant ProcedureSeparator Tank Scavenge SCREEN/ORIFICE Tools Required Coolant Separator Element Tank cover bolt torque valuesRecommended Bolt Tightening Cross Pattern 125/200 HPCooler Cores Cleaning Coolant CoolersAftercooler Aftercooler CleaningAftercooler Motor Lubrication Relubrication amount Lubricant Amount Motor Frame Size GramsMotor Bearing Maintenance Stored Units Motor LubricationRecommended Motor Grease Hazardous voltage. Can cause severe injury or deathLong Term Storage General Intellisys RemovalTools Controller RemovalInstallation Coolant Sampling ProcedureCoolant Hoses RemovalAIR Cooled Compressors Design Temperatures General System InformationCoolant Cooler Cooling FAN MotorCompressed AIR System The air system is composed COOLANT/AIR Separation SystemOperation Electrical SystemSTAR-DELTA Type Starter Stepper Motor Inlet ControlCapacity Control Automatic Unloaded StartAutomatic START/STOP Control Modulation onlyFirst Some Examples of Operation SecondExample Remote START/STOP Troubleshooting Chart Troubleshooting Chart Power Outage Restart Option SequencerLOW Ambient Separator DELTA-P SolenoidRemote LOAD/UNLOAD ModbusElectrical Schematic Star Delta Reference DrawingsPage Foundation Plan 125-150 HP/90-110KW Aircooled Single Stage Foundation Plan 125-150 HP/90-110 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage REV C REV C Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan Aircooled 100-150 HP/75-110 KW TWO StageFoundation Plan Aircooled 100-150 HP/75-110 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED Foundation Plan -WATERCOOLED 100-150 HP/75-110 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Flow Schematic Aircooled Single Stage Page Flow Schematic Watercooled 90F 32C Single Stage Page Flow Schematic Watercooled 115F 46 Single Stage Page Flow Schematic AIR-COOLED TWO Stage Page Flow Schematic Watercooled 90F 32C TWO Stage Page Flow Schematic Watercooled 115F 46C TWO Stage Page Typical System Flow Diagram Typical System Flow DiagramsTypical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Scale CorrosionFouling Parameter Concentration Frequency of AnalysisPage Temperature F Total dissolved solids ppmHardness ppm Alkalinity ppmMaintenance Record Maintenance Record Maintenance Record Maintenance Record