4.10 MOTOR LUBRICATION

The induction-type squirrel cage motors have antifriction ball or roller bearings front and rear. At periodic intervals they require relubrication.

 

Relubrication Interval - 60 Hz

 

 

 

(or 9 months, whichever comes first)

 

 

 

1000 hours

......................................

all TEFC drive motors

 

2000 hours

.........all ODP drive motors and all fan motors

 

Relubrication amount

 

 

 

 

 

 

 

 

 

 

 

 

Lubricant Amount

 

Motor Frame Size

in3

cc

oz.

grams

 

 

 

 

 

 

 

 

182-215

 

.5

8

.4

11

 

254-286

 

1.0

16

.8

23

 

324-365

 

1.5

25

1.2

34

 

404-449

 

2.5

40

2.0

57

 

5000 Frame Series

1.0

16

.8

23

 

 

 

 

 

Relubrication Interval - 50 Hz

 

 

 

(or 9 months, whichever comes first)

 

 

2000 hours

M90 - 160 KW TEFC drive motors

4000 hours

 

M75 TEFC drive motors

Relubrication amount

 

 

Lubricant Amount

Motor Frame Size

in3

cc

oz. grams

 

 

M75-160

As indicated on motor

 

nameplate

 

 

 

 

 

Improper lubrication can be a cause of motor bearing failure. The quantity of grease added should be carefully controlled. The smaller motors must be greased with a lesser amount of grease than larger motors.

CAUTION

Overgreasing can be a cause of bearing and motor failure. Make sure dirt and contaminants are not introduced when adding grease.

Procedure for relubrication

CAUTION

Grease should be added when the motor

is stopped and power disconnected.

When regreasing, stop motor. Disconnect power; lock out and tag. Remove outlet plugs (or spring-loaded grease relief plugs if present). The outlet plug may not be accessible on the fan end of some TEFC motors.

NOTICE

Motors must be greased periodically.

See Operator’s Manual for procedure.

36

Image 38
Contents Phone CCN 80440415 REV B Form Apdd 738BAIR Compressor Group Bonded Warranty & Registered Start UP Rotary Screw AIR Compressor This unit was purchased fromTable of Contents Safety and Warnings Safety Shutdown Lift Here DecalsDecals Viewed From RearCompressor Package Data Unpacking and Handling InspectionIngersoll-Rand Company Davidson, North Carolina ToolsNever elevate the compressor unit VentilationFoundation Requirements Performance will be affectedDo not use the compressor to support the discharge pipe Moisture Content of Compressed AIRPiping Discharge Piping with Aftercooler ROTARY-RECIP in ParallelElectrical Installation Rotary TWO Compressor SystemRotation Check Drive MotorFAN Motor Electrical InstallationHasp Lever TAG KEY Lock Intellisys Operating InstructionsOutdoor Sheltered Installation 1 Typical Outdoor Sheltered Installation Intellisys Intellisys ControllerStart Power on LightIntellisys Controls Emergency Stop StopCurrent Status Items Display ScreenCurrent Status Panel Flow Figure DiagramOperator IntellisysMain Menu Operator SetpointsOptions Options Items Range Step UnitOptions Sensor Calibration Items Alarm HistorySensor Calibration Alarm History Items Clock FunctionsIntegral Sequencing Integral Sequencing Range Step UnitStatus Main Menu Reset Alarms Alarm Main MenuPage Maintenance Procedures Maintenance ScheduleMaintenance Records Number of Running HOURS, Whichever Occurs First200 HP/132-160 KW Requires 2 Elements Inlet AIR FilterCoolant Filter ElementsCoolant Drain CoolantItems Required Hot coolant can cause severe injurySeparator Tank Scavenge SCREEN/ORIFICE Tools Required ProcedureCoolant Recommended Bolt Tightening Cross Pattern Coolant Separator ElementTank cover bolt torque values 125/200 HPCooler Cores Cleaning Coolant CoolersAftercooler Aftercooler CleaningAftercooler Motor Lubrication Relubrication amount Lubricant Amount Motor Frame Size GramsRecommended Motor Grease Motor Bearing Maintenance Stored UnitsMotor Lubrication Hazardous voltage. Can cause severe injury or deathTools Long Term Storage GeneralIntellisys Removal Controller RemovalCoolant Hoses InstallationCoolant Sampling Procedure RemovalCoolant Cooler AIR Cooled Compressors Design TemperaturesGeneral System Information Cooling FAN MotorOperation Compressed AIR System The air system is composedCOOLANT/AIR Separation System Electrical SystemCapacity Control STAR-DELTA Type StarterStepper Motor Inlet Control Automatic Unloaded StartFirst Modulation onlyAutomatic START/STOP Control Example SecondSome Examples of Operation Remote START/STOP Troubleshooting Chart Troubleshooting Chart LOW Ambient Power Outage Restart OptionSequencer Separator DELTA-P SolenoidRemote LOAD/UNLOAD ModbusElectrical Schematic Star Delta Reference DrawingsPage Foundation Plan 125-150 HP/90-110KW Aircooled Single Stage Foundation Plan 125-150 HP/90-110 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage REV C REV C Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan Aircooled 100-150 HP/75-110 KW TWO StageFoundation Plan Aircooled 100-150 HP/75-110 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED Foundation Plan -WATERCOOLED 100-150 HP/75-110 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Flow Schematic Aircooled Single Stage Page Flow Schematic Watercooled 90F 32C Single Stage Page Flow Schematic Watercooled 115F 46 Single Stage Page Flow Schematic AIR-COOLED TWO Stage Page Flow Schematic Watercooled 90F 32C TWO Stage Page Flow Schematic Watercooled 115F 46C TWO Stage Page Typical System Flow Diagram Typical System Flow DiagramsTypical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Fouling ScaleCorrosion Parameter Concentration Frequency of AnalysisPage Hardness ppm Temperature FTotal dissolved solids ppm Alkalinity ppmMaintenance Record Maintenance Record Maintenance Record Maintenance Record