Ingersoll-Rand 125-200 HP/90-160 KW, 100-200 HP/75-160 KW technical manual Troubleshooting Chart

Page 49

6.0 TROUBLESHOOTING CHART (Continued)

 

 

 

 

 

 

 

 

 

TROUBLE

 

CAUSE &/OR DISPLAY

 

 

 

 

 

 

WHAT TO DO

 

 

 

 

 

 

 

 

 

 

Low system air pressure

 

Compressor running in

 

Press LOAD button.

 

 

 

 

UNLOAD Mode.

 

 

 

 

 

 

 

Controller off-line set point too low.

 

Press STOP button.

 

 

 

 

 

 

 

Set off-line set point at a higher value.

 

 

 

 

Dirty air filter element.

 

Check filter condition. Replace as required.

 

 

 

 

Air leak.

 

Check air system piping.

 

 

 

 

Moisture separator trap drain

 

Inspect and repair.

 

 

 

 

stuck open.

 

 

 

 

 

 

 

Inlet valve not fully open.

 

Inspect and repair. Check control system operation.

 

 

 

 

System demand exceeds compressor

 

Install larger or an additional compressor.

 

 

 

 

delivery.

 

 

 

 

 

 

 

 

 

 

 

 

High coolant

 

Excessive coolant level.

 

Check level, lower if necessary by draining.

 

 

consumption/coolant in

 

 

 

 

 

 

 

air system

 

Plugged separator element.

 

Check separator pressure drop.

 

 

 

 

Separator element leak.

 

Check separator pressure drop. If low, replace element.

 

 

 

 

Plugged separator scavenge

 

Remove and inspect screen/orifice. Clean if required.

 

 

 

 

screen/orifice.

 

 

 

 

 

 

 

Compressor operating at low pressure

 

Operate at rated pressure. Reduce system load.

 

 

 

 

(75 psig [5.2 bar] or below).

 

 

 

 

 

 

 

Coolant system leak.

 

Inspect and repair leaks.

 

 

 

 

 

 

 

 

 

Water in air system

 

Defective moisture

 

Inspect and clean if required.

 

 

 

 

separator/drain trap

 

 

Replace separator/trap if defective.

 

 

 

 

Trap drain or drain piping plugged.

 

Inspect and clean.

 

 

 

 

Aftercooler core dirty.

 

Inspect and clean.

 

 

 

 

Enclosure panels not in place.

 

Install enclosure panels.

 

 

 

 

No aftercooler on unit.

 

Install aftercooler.

 

 

 

 

Drain line/drip leg incorrectly installed.

 

Slope drain line away from trap. Install drip leg.

 

 

 

 

No refrigerated or desiccant dryer

 

 

 

 

 

 

 

in air system.

 

Contact local Ingersoll-Rand distributor.

 

 

 

 

 

 

 

 

 

Excessive noise level

 

Compressor defective. (Bearing or gear

 

Contact authorized distributor immediately.

 

 

 

 

failure or rotor contact.)

 

 

Do not operate unit.

 

 

 

 

Enclosure panels not in place.

 

Install enclosure panels.

 

 

 

 

Loose component mounting.

 

Inspect and tighten.

 

 

 

 

 

 

 

 

 

 

Excessive vibration

 

Loose components.

 

Inspect and tighten.

 

 

 

 

Motor or compressor

 

Contact authorized distributor immediately.

 

 

 

 

bearing failure.

 

 

Do not operate unit.

 

 

 

 

External sources.

 

Inspect area for other equipment.

 

 

 

 

 

 

 

 

 

Pressure relief valve

 

Compressor operating over pressure.

 

Adjust Intellisys set points.

 

 

opens

 

Defective valve.

 

 

 

 

 

 

 

 

 

Replace valve.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47

Image 49
Contents Form Apdd 738B Phone CCN 80440415 REV BAIR Compressor Group Bonded Warranty & Registered Start UP This unit was purchased from Rotary Screw AIR CompressorTable of Contents Safety and Warnings Safety Shutdown Decals Lift HereViewed From Rear DecalsCompressor Package Data Ingersoll-Rand Company Davidson, North Carolina InspectionUnpacking and Handling ToolsFoundation Requirements VentilationNever elevate the compressor unit Performance will be affectedPiping Moisture Content of Compressed AIRDo not use the compressor to support the discharge pipe Discharge Piping with Aftercooler ROTARY-RECIP in ParallelRotary TWO Compressor System Electrical InstallationDrive Motor Rotation CheckHasp Lever TAG KEY Lock Electrical InstallationFAN Motor Intellisys Operating InstructionsOutdoor Sheltered Installation 1 Typical Outdoor Sheltered Installation Intellisys Controller IntellisysIntellisys Controls Emergency Stop Power on LightStart StopCurrent Status Display ScreenCurrent Status Items Operator DiagramPanel Flow Figure IntellisysOperator Setpoints Main MenuOptions Items Range Step Unit OptionsOptions Sensor Calibration Alarm HistorySensor Calibration Items Clock Functions Alarm History ItemsIntegral Sequencing Range Step Unit Integral SequencingStatus Main Menu Reset Alarm Main Menu AlarmsPage Maintenance Records Maintenance ScheduleMaintenance Procedures Number of Running HOURS, Whichever Occurs FirstCoolant Filter Inlet AIR Filter200 HP/132-160 KW Requires 2 Elements ElementsItems Required CoolantCoolant Drain Hot coolant can cause severe injuryCoolant ProcedureSeparator Tank Scavenge SCREEN/ORIFICE Tools Required Tank cover bolt torque values Coolant Separator ElementRecommended Bolt Tightening Cross Pattern 125/200 HPCoolant Coolers Cooler Cores CleaningAftercooler Aftercooler CleaningAftercooler Relubrication amount Lubricant Amount Motor Frame Size Grams Motor LubricationMotor Lubrication Motor Bearing Maintenance Stored UnitsRecommended Motor Grease Hazardous voltage. Can cause severe injury or deathIntellisys Removal Long Term Storage GeneralTools Controller RemovalCoolant Sampling Procedure InstallationCoolant Hoses RemovalGeneral System Information AIR Cooled Compressors Design TemperaturesCoolant Cooler Cooling FAN MotorCOOLANT/AIR Separation System Compressed AIR System The air system is composedOperation Electrical SystemStepper Motor Inlet Control STAR-DELTA Type StarterCapacity Control Automatic Unloaded StartAutomatic START/STOP Control Modulation onlyFirst Some Examples of Operation SecondExample Remote START/STOP Troubleshooting Chart Troubleshooting Chart Sequencer Power Outage Restart OptionLOW Ambient Separator DELTA-P SolenoidModbus Remote LOAD/UNLOADReference Drawings Electrical Schematic Star DeltaPage Foundation Plan 125-150 HP/90-110KW Aircooled Single Stage Foundation Plan 125-150 HP/90-110 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage REV C REV C Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan 200 HP/132-160 KW Watercooled Single Stage 100-150 HP/75-110 KW TWO Stage Foundation Plan AircooledFoundation Plan Aircooled 100-150 HP/75-110 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED Foundation Plan -WATERCOOLED 100-150 HP/75-110 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Flow Schematic Aircooled Single Stage Page Flow Schematic Watercooled 90F 32C Single Stage Page Flow Schematic Watercooled 115F 46 Single Stage Page Flow Schematic AIR-COOLED TWO Stage Page Flow Schematic Watercooled 90F 32C TWO Stage Page Flow Schematic Watercooled 115F 46C TWO Stage Page Typical System Flow Diagrams Typical System Flow DiagramTypical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Corrosion ScaleFouling Parameter Concentration Frequency of AnalysisPage Total dissolved solids ppm Temperature FHardness ppm Alkalinity ppmMaintenance Record Maintenance Record Maintenance Record Maintenance Record