6.0 TROUBLESHOOTING CHART (Continued)
|
|
|
|
|
|
|
|
| TROUBLE |
| CAUSE &/OR DISPLAY |
|
|
| |
|
|
| WHAT TO DO |
| |||
|
|
|
|
|
|
|
|
| Low system air pressure |
| Compressor running in |
| ■ | Press LOAD button. |
|
|
|
| UNLOAD Mode. |
|
|
|
|
|
|
| Controller |
| ■ | Press STOP button. |
|
|
|
|
|
|
| Set |
|
|
|
| Dirty air filter element. |
| ■ Check filter condition. Replace as required. |
| |
|
|
| Air leak. |
| ■ Check air system piping. |
| |
|
|
| Moisture separator trap drain |
| ■ | Inspect and repair. |
|
|
|
| stuck open. |
|
|
|
|
|
|
| Inlet valve not fully open. |
| ■ Inspect and repair. Check control system operation. |
| |
|
|
| System demand exceeds compressor |
| ■ Install larger or an additional compressor. |
| |
|
|
| delivery. |
|
|
|
|
|
|
|
|
|
|
| |
| High coolant |
| Excessive coolant level. |
| ■ Check level, lower if necessary by draining. |
| |
| consumption/coolant in |
|
|
|
|
|
|
| air system |
| Plugged separator element. |
| ■ Check separator pressure drop. |
| |
|
|
| Separator element leak. |
| ■ Check separator pressure drop. If low, replace element. |
| |
|
|
| Plugged separator scavenge |
| ■ | Remove and inspect screen/orifice. Clean if required. |
|
|
|
| screen/orifice. |
|
|
|
|
|
|
| Compressor operating at low pressure |
| ■ Operate at rated pressure. Reduce system load. |
| |
|
|
| (75 psig [5.2 bar] or below). |
|
|
|
|
|
|
| Coolant system leak. |
| ■ Inspect and repair leaks. |
| |
|
|
|
|
|
|
| |
| Water in air system |
| Defective moisture |
| ■ Inspect and clean if required. |
| |
|
|
| separator/drain trap |
|
| Replace separator/trap if defective. |
|
|
|
| Trap drain or drain piping plugged. |
| ■ | Inspect and clean. |
|
|
|
| Aftercooler core dirty. |
| ■ | Inspect and clean. |
|
|
|
| Enclosure panels not in place. |
| ■ | Install enclosure panels. |
|
|
|
| No aftercooler on unit. |
| ■ | Install aftercooler. |
|
|
|
| Drain line/drip leg incorrectly installed. |
| ■ | Slope drain line away from trap. Install drip leg. |
|
|
|
| No refrigerated or desiccant dryer |
|
|
|
|
|
|
| in air system. |
| ■ Contact local |
| |
|
|
|
|
|
|
| |
| Excessive noise level |
| Compressor defective. (Bearing or gear |
| ■ Contact authorized distributor immediately. |
| |
|
|
| failure or rotor contact.) |
|
| Do not operate unit. |
|
|
|
| Enclosure panels not in place. |
| ■ | Install enclosure panels. |
|
|
|
| Loose component mounting. |
| ■ | Inspect and tighten. |
|
|
|
|
|
|
|
|
|
| Excessive vibration |
| Loose components. |
| ■ | Inspect and tighten. |
|
|
|
| Motor or compressor |
| ■ Contact authorized distributor immediately. |
| |
|
|
| bearing failure. |
|
| Do not operate unit. |
|
|
|
| External sources. |
| ■ Inspect area for other equipment. |
| |
|
|
|
|
|
|
| |
| Pressure relief valve |
| Compressor operating over pressure. |
| ■ Adjust Intellisys set points. |
| |
| opens |
| Defective valve. |
|
|
|
|
|
|
|
|
| Replace valve. |
| |
|
|
|
|
| ■ |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
47