Ingersoll-Rand 100-200 HP/75-160 KW, 125-200 HP/90-160 KW technical manual Safety Shutdown

Page 6

SAFETY SHUTDOWN

CHECK HIGH AIR TEMPERATURE

There is a high discharge air temperature shutdown function built into the Intellisys on each compressor. It is factory pre-set at 228°F (109°C). This function should be checked at regular intervals for proper operation, once a month is recommended. The procedure is:

1.Block off the cooling air discharge.

2.The compressor discharge temperature will rise at a rapid rate. Shutdown should occur when the discharge temperature reaches the pre-set maximum discharge air temperature setting of the Intellisys. The display should indicate “HIGH AIREND DISCH TEMP” and flash “ALARM”.

The actual temperature at which shutdown occurs should be recorded for comparison to the Intellisys set point and with similar future test results.

WARNING

Failure to adhere to these recommendations can result in mechanical failure, property damage and serious injury or death.

All air and water inlet, and air and water discharge pipework to and from the inlet and discharge port connections must take into account vibration, pulsations, temperature, maximum pressure applied, corrosion and chemical resistance. In addition, it should be noted that lubricated compressors will discharge some oil into the air stream; therefore, compatibility between discharge piping, system accessories and software must be assured.

For the foregoing reasons, the use of plastic piping, soldered copper fittings and rubber hose as discharge piping is not recommended. In addition, flexible joints and/or flex lines can only be considered for such purposes if their specifications fit the operating parameters of the system.

It is the responsibility of the installer and owner to provide the appropriate service pipework to and from the machine.

WARNING

“Ingersoll-Rand air compressors are not designed, intended, or approved for breathing air. Ingersoll-Rand does not approve specialized equipment for breathing air application and assumes no responsibility or liability for compressors used for breathing air services.”

4

Image 6
Contents Phone CCN 80440415 REV B Form Apdd 738BAIR Compressor Group Bonded Warranty & Registered Start UP Rotary Screw AIR Compressor This unit was purchased fromTable of Contents Safety and Warnings Safety Shutdown Lift Here DecalsDecals Viewed From RearCompressor Package Data Unpacking and Handling InspectionIngersoll-Rand Company Davidson, North Carolina ToolsNever elevate the compressor unit VentilationFoundation Requirements Performance will be affectedDo not use the compressor to support the discharge pipe Moisture Content of Compressed AIRPiping Discharge Piping with Aftercooler ROTARY-RECIP in ParallelElectrical Installation Rotary TWO Compressor SystemRotation Check Drive MotorFAN Motor Electrical InstallationHasp Lever TAG KEY Lock Intellisys Operating InstructionsOutdoor Sheltered Installation 1 Typical Outdoor Sheltered Installation Intellisys Intellisys ControllerStart Power on LightIntellisys Controls Emergency Stop StopDisplay Screen Current StatusCurrent Status Items Panel Flow Figure DiagramOperator IntellisysMain Menu Operator SetpointsOptions Options Items Range Step UnitOptions Alarm History Sensor CalibrationSensor Calibration Items Alarm History Items Clock FunctionsIntegral Sequencing Integral Sequencing Range Step UnitStatus Main Menu Reset Alarms Alarm Main MenuPage Maintenance Procedures Maintenance ScheduleMaintenance Records Number of Running HOURS, Whichever Occurs First200 HP/132-160 KW Requires 2 Elements Inlet AIR FilterCoolant Filter ElementsCoolant Drain CoolantItems Required Hot coolant can cause severe injuryProcedure CoolantSeparator Tank Scavenge SCREEN/ORIFICE Tools Required Recommended Bolt Tightening Cross Pattern Coolant Separator ElementTank cover bolt torque values 125/200 HPCooler Cores Cleaning Coolant CoolersAftercooler Cleaning AftercoolerAftercooler Motor Lubrication Relubrication amount Lubricant Amount Motor Frame Size GramsRecommended Motor Grease Motor Bearing Maintenance Stored UnitsMotor Lubrication Hazardous voltage. Can cause severe injury or deathTools Long Term Storage GeneralIntellisys Removal Controller RemovalCoolant Hoses InstallationCoolant Sampling Procedure RemovalCoolant Cooler AIR Cooled Compressors Design TemperaturesGeneral System Information Cooling FAN MotorOperation Compressed AIR System The air system is composedCOOLANT/AIR Separation System Electrical SystemCapacity Control STAR-DELTA Type StarterStepper Motor Inlet Control Automatic Unloaded StartModulation only Automatic START/STOP ControlFirst Second Some Examples of OperationExample Remote START/STOP Troubleshooting Chart Troubleshooting Chart LOW Ambient Power Outage Restart OptionSequencer Separator DELTA-P SolenoidRemote LOAD/UNLOAD ModbusElectrical Schematic Star Delta Reference DrawingsPage Foundation Plan 125-150 HP/90-110KW Aircooled Single Stage Foundation Plan 125-150 HP/90-110 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage Foundation Plan 200 HP/132-160 KW Aircooled Single Stage REV C REV C Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan 200 HP/132-160 KW Watercooled Single Stage Foundation Plan Aircooled 100-150 HP/75-110 KW TWO StageFoundation Plan Aircooled 100-150 HP/75-110 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan Aircooled 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED Foundation Plan -WATERCOOLED 100-150 HP/75-110 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Foundation Plan -WATERCOOLED 200 HP/132-160 KW TWO Stage Flow Schematic Aircooled Single Stage Page Flow Schematic Watercooled 90F 32C Single Stage Page Flow Schematic Watercooled 115F 46 Single Stage Page Flow Schematic AIR-COOLED TWO Stage Page Flow Schematic Watercooled 90F 32C TWO Stage Page Flow Schematic Watercooled 115F 46C TWO Stage Page Typical System Flow Diagram Typical System Flow DiagramsTypical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Typical System Flow Diagrams Fouling ScaleCorrosion Parameter Concentration Frequency of AnalysisPage Hardness ppm Temperature FTotal dissolved solids ppm Alkalinity ppmMaintenance Record Maintenance Record Maintenance Record Maintenance Record