GE LCB AJCS 10, ACB AJCQ 10 Safety, Fan Switch, Vent Control, Troubleshooting Tips Air Direction

Page 5

www.GEAppliances.com

COOL MODE

Safety

Remote Control

1.Press COOL pad.

2.Press LOW, MED or HI pads to set desired fan speed.

3.Press the INCREASE / DECREASE pads to set the desired temperature 60°F to 85°F in 1°F increments.

Control Panel

1.Press the MODE pad until the COOL indicator light is lit and the LOW, MED or HI indicator light is lit for the desired fan speed.

2.Press the INCREASE / DECREASE pads to set the desired temperature 60°F to 85°F in 1°F increments.

A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will

become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling—Select the COOL mode and HIGH or MED fan with a middle set temperature.

For Maximum Cooling—Select the COOL mode and HIGH fan with a lower set temperature.

For Quieter & Nighttime Cooling—Select the COOL mode and LOW fan with a middle set temperature.

NOTE: If you switch from a COOL setting to OFF or to

a fan setting, wait at least 3 minutes before switching back to a COOL setting.

Instructions Operating Instructions Care

Fan Switch

The fan switch is located behind the front grille on the

When set at CONT (continuous, up) the fan runs all the

control box. Access through a hole in control box.

time providing a more balanced temperature. The unit

When set at CYCLE (down) the fan cycles on and off.

is shipped in the CONT setting.

 

and Cleaning

FAN MODE

Use the FAN mode to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a temperature setting will not be displayed.

Remote Control

Press FAN pad. Press LOW, MED or HI pads to set desired fan speed.

Control Panel

Press the MODE pad until the FAN indicator light is lit and the LOW, MED or HI indicator light is lit for the desired fan speed.

Installation Instructions

Vent Control

The vent control is located behind the front grille on the right side of the air discharge area. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open or close the vent:

1.Remove the front grille.

2.Remove the vent card screw.

3.Remove vent card, turn it over and replace it by locating rear hole in card over locating pin inside air discharge and reattaching screw at front.

The unit leaves the factory set at the CLOSE position.

Locating hole

Locating hole

Screw hole

Screw hole

OPEN position

CLOSE position

(Mesh end toward back)

(Mesh end toward front)

Troubleshooting Tips

Air Direction

Horizontal louvers

Remove the front

 

on the front grille let

grille to adjust the

 

you control the air

vertical louvers

 

direction up and

side-to-side to

 

down.

direct the air

 

 

left or right.

5

 

 

Consumer Support

Image 5
Contents Serial # Write the model and serial numbers hereInstructions Care and Cleaning Operating InstructionsCare Operating InstructionsTips Consumer Support Instructions Consumer Remote ControlFan Switch SafetyTroubleshooting Tips Air Direction Vent ControlAuxiliary Controls Temperature Limiting Page Cooling/Heating Descriptions Mode ControlHeat Pump Models Temp ControlCleaning Installation Temperature LimitingCleaning Operating Instructions Safety Instructions Care and cleaning of the air conditionerGrille and Case Outdoor CoilsAir Filter How to Insert the BatteriesModel Qualifying Questions Before YOU BeginElectrical Requirements GE KIT Numbers Tools YOU MAY NeedAttach Front Grille Installing a J-MODEL in AN Existing Wall CaseSupport Requirements for AIR Conditioner Installing Through the WallPrepare Opening in Wall Window Requirements Window INSTALLATION-OPTIONALWood Pieces Width 2″ Storm Window RequirementsPrepare Window Install Sill SupportsRight Left MEASURE, CUT and Install Filler PanelsInstall Case in Window Replace AIR Conditioner in Case Install Window Gasket and Locking BracketConsumer Support Normal Operating Sounds Before you call for service…Troubleshooting Tips Consumer Support Air Conditioner WarrantyGE Will Replace For The PeriodInstructions de sécurité Instructions de fonctionnement Avertissement Nettoyage Cas de panne Instructions de montage Entretien etTélécommande Sécurité Consommateur En cas de panne Commande d’éventInterrupteur du ventilateur Direction de l’airCommandes auxiliaires Limitation de température Commande de la température Commande du modeDe sécurité Instructions de montageDirection de la sortie d’air Limitation de la températureGrille et boîtier Entretien et nettoyage du conditionneurSerpentins extérieurs Pour retirerComment insérer les piles Mise EN Garde Ne faitesFiltre à air Exigences EN Matière ’ALIMENTATION Électrique Avant DE CommencerNuméros DE Trousses GE Outils Dont Vous Pouvez Avoir BesoinGlissez Délicatement LE Conditionneur Dans LE Logement Retirez LA Plaque DE Verrouillage SUR LE Côté Gauche Avant’AIDE D’UNE Agrafe Fixez LA Grille FrontaleSupport DU Conditionneur Installation À Travers LE MURPréparation DE L’OUVERTURE Dans LE MUR Instructions Relatives À LA Fenêtre Installation DE Fenêtre EN OptionRetirez LE Conditionneur DE SON Logement Instructions Relatives À LA CONTRE-FENÊTREPréparez LA Fenêtre Installez LES Supports DE SeuilMESUREZ, Coupez ET Installez LES Panneaux DE Fermeture Montez LE Logement Dans LA Fenêtre Replacez LE Conditionneur Dans SON Logement Bruits normaux de fonctionnement Avant d’appeler le serviceNous remplacerons Garantie du conditionneur d’airCe qui n’est pas couvert Et nettoyage Instructions de montage EnProlongation de garantie Service de réparationsSoutien au consommateur Serie No Cuidado y limpiezaCuidado y limpieza Apoyo al consumidor Solucionar problemasPrecaución Limpieza Instalación Solucionar problemasControl remoto Control remotoLimpieza Modo FAN Ventilador Interruptor del ventiladorControl del escape Dirección del aireControles auxiliares-Limitación de temperatura Apoyo al consumidor Solucionar problemas InstalaciónNotas Control de la temperatura Descripciones de enfriamientoModelos con bomba de calor Para calefacción máxima SeleccioneDependiendo Del modelo Límite de la temperaturaRejilla y caja Cuidado y limpieza del acondicionador de aireBobinas exteriores Rejilla delanteraCómo insertar las baterías Precaución No opere elFiltro de aire Requisitos Eléctricos Antes DE IniciarNúmeros DE KIT DE GE Herramientas QUE Podría NecesitarUNA LA Rejilla Delantera Cómo Instalar UN Modelo J EN UNA Caja DE Pared ExistentePrepare LA Abertura DE LA Pared Cómo Instalar a Través DE LA ParedRequisitos Para EL Apoyo DEL Acondicionador DE Aire Requisitos DE Apoyo Para EL Acondicionador DE AireRequisitos Para LA Ventana Instalación DE VENTANA-OPCIONALRetire EL Acondicionador DE Aire DE LA Caja Requisitos DE Ventana Para TormentaInstale LOS Soportes DE LA Alfajía Exterior Prepare LA VentanaCentro MIDA, Corte E Instale LOS Paneles DE RellenoInstale LA Caja EN LA Ventana Reemplace EL Acondicionador DE Aire EN LA Caja Instale EL Empaque Para LA Ventana Y EL Soporte DE BloqueoSonidos de operación normales Antes de llamar para solicitar servicio…Notas Limpieza Garantía de su acondicionador de aireNosotros reemplazaremos Lo que no está cubiertoSolicite una reparación Apoyo al Consumidor Página Web de GE AppliancesGarantías ampliadas Piezas y accesoriosParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio