Genie 1042 manual Securely fasten wires, Do not install rear cover yet, Mounting

Page 16
Insulated
Staple

3.Securely fasten wires.

Securely fasten wires to ceiling and wall using insulated staples provided.

– Use insulated staples.

– Staples should be snug only.

• If rear cover is attached to power head, remove it.

On power head:

Route Wall Button wires through wire guide.

Split and strip ends of wire (Fig. 3-2 on previous page).

Insert wire into terminal holes and lightly press in the orange locking clips above each terminal hole. (You can use a pencil or small screwdriver to comfortably press in locking clips.) The white wire into #1 terminal hole and striped wire into the #2 terminal hole.

Confirm wire lock by lightly tugging on the wire. The wire should remain in the terminal hole.

Do NOT install rear cover yet.

Locking

 

 

 

 

 

 

 

 

 

Clips

 

 

 

Terminal

 

 

 

 

 

 

 

 

 

 

Holes

 

 

 

 

 

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

+ –

 

 

 

 

 

 

 

 

 

P

B

 

 

 

 

 

InfaredSensor

 

 

 

(Power Head With Rear Cover Removed) FIG. 3-3 Insert wires.

4.Mounting.

• Fasten Wall Button to wall with 2 screws

(provided) (Fig. 3-4).

• Remove protective backing from "Entrapment" warning label (Fig. 3-5). The "Entrapment" label is located in the center of this manual.

– Stick label on wall near Wall Button.

FIG. 3-4 Mounting Wall Button.

FIG. 3-5 Mounting Entrapment warning label.

16

PN# 36420Supplement, 10/27/2008

Image 16
Contents CHAINLIFT/BELTLIFT Models 1022/1024/1042 Turn OFF power before removing operator cover System technician using proper tools and instructionsKeep people clear of opening while door is moving Do not allow children to play with the door operatorOpener Features Table of ContentsSafety Features Do not USE AN Extension Cord Typical Sectional Door Installation Pg PgRecommended Tools Parts Identification Not Shown Full SizeDo not Return to Point of Purchase Chain Piece Rail Hardware Assembled ViewImportant Installation Instructions Opener AssemblyChain Power Head & Rail Assembly Use 16-18 x 1/2 BoltsFinding header bracket mounting location Installation Header and Door Mounting BracketsDo not move door spring Mounting the header bracket Mounting the assembly Mounting the OpenerGetting started Attach angle iron to beamsInstall Door Arms Door BracketWall Button Installation 2a. Wiring If pre-wired2b. Wiring If not pre-wired Wall Button locationDo not install rear cover yet Securely fasten wiresMounting 3a. Wiring If not pre-wired SAFE-T-BEAMSYSTEM InstallationMounting Safe-T-BeamSource Red LED and Sensor Green LED Route Safe-T-Beamwires through wire guide 3b. Wiring pre-wiredDo not install the white lamp cover at this time Connecting to Power With Permanent WiringWith Power Supplied With Grounded PlugDoor Limits Setting & Testing OPEN/CLOSE LimitsClose Travel Limit Keyed Emergency Release Carriage LockKeyed Emergency Release Operation Instructions Erase OPEN/CLOSE Travel Limit UP/DOWN ForceContact Reverse Test Programming Remote Controls Lost or Stolen RemoteLight BULB/LENS Installation Battery replacementVisor clip Light bulbMaintenance Routine Monthly MaintenanceDoor balance Contact reverseCircuit Wiring Diagram Advertencia AvertissementTroubleshooting Guide Operation Problem What to doTroubleshooting Guide Power Head LED Possible Problem SolutionTransmitter Compliance Statement Page This page left blank Solution Possible Problème ClignoteSolución Problema Posible Fonctionnement Dépannage DE Guide Funcionamiento DE Problema Averías DE Investigación DE Guía Del funcionamiento MalAvertissement Maintenance AdvertenciaMantenimiento Rutina DEAvertissement Lentille la Fixer Lente la AprieteViseur du clip le Fixer Visera de sujetador el Acople Pile la’IC DE ET FCC LA DE Reglementation LA a Conforme Robado O Perdido RemotoRemotos Controles DE Programación BotónInverso Contacto DE Prueba Cerrar ABRIR/ DE Recorrido DEL Límite BorrarHAUT/BAS Force Puerta la de vano Del centro del debajo 4 xAvertissement Advertencia CLÉSecours DE Déverrouillage CON Pestillo DE PicaporteAdvertencia Puerta LA DE LímitesABRIR/CERRAR Corredizo al cadena la EngranaProtección DE Función InfrarrojaTension Sous Garde EN Mise PrecauciónGarde EN Mise PrecauciónArrière couvercle le Installer Posterior tapa la InstaleCouvercle du Clips Tapa la de PresillasFuente y detector Del alambrado de Métodos Beam-T-Safe del Fuente y detector del LugaresMontaje de Soportes Soportes Los a detectores los AcoplePuerta la de marco el Marque Coinçage MuraleMontaje MontagePared DE Control DEL Instalación Dénudage et DivisionPelando y Partiendo Pared de control Del alambre de RecorridoPuerta LA DE Soporte ’OUVREUR DE Montage Installation InstalaciónRiel DEL 10/27/2008 36420Supplement, PN#Cadena la de Ajuste Control De caja la de Conjunto RielRiel de partidas Secciones Partido riel del ConjuntoPORTE-OUVRE pour rail de Ensemble ’OUVREUR Abridor DEL ConjuntoLa de l’ouvreur installer possible, du mesure la Dans De risque de d’AVERTISSEMENT l’étiquette PlacerAssemblée Pièce 1 À Rail DU Quincaillerie LA DE VUE Pieza 1 DE Riel DEL Herrajes DE Montaje DEL VistaMANQUANTES? Pièces Recommandés Outils Recomendadas Herramientas 12 .Pg / .Pág 11 .Pg / .Pág 18-17 .Pg14 .Pg OU / OSection la à reporter se installée fois une Aluminium, léger, acier en plaques desElle-t-a section a garage de porte Votre Section à référer Se .librement4 Secciones las a Refiérase Matières DES Table ÍndiceSeguridad DE Características Abridor DEL CaracterísticasMobiles pièces Terre la à mis correctement être doit l’ouvreurMouvement Beltliftchainlift

1042 specifications

The Genie 1042 is a versatile and efficient aerial work platform designed to meet the demands of various industries, from construction to maintenance and operations. This compact boom lift is renowned for its remarkable lifting capabilities and user-friendly features, making it a favorite among professionals seeking reliability and performance.

One of the standout features of the Genie 1042 is its impressive working height, reaching up to 40 feet, and a horizontal outreach of 22 feet. This combination of height and reach makes it ideal for tasks that require working at significant elevations while still maintaining a solid base. The platform extends and retracts smoothly, providing operators with the flexibility to navigate around obstacles and access hard-to-reach areas effectively.

Powered by an efficient electric motor, the Genie 1042 operates quietly, making it suitable for indoor use and residential areas where noise restrictions may be a factor. The electric motor also offers zero emissions, aligning with modern environmental standards and preferences for greener equipment. Its compact design, with a width of just 4 feet, allows it to maneuver easily through standard doorways and tight spaces, enhancing its practicality on job sites.

Safety is a priority with the Genie 1042, featuring an intuitive operator control system and standard safety measures, including a tilt sensor and emergency stop buttons. The platform is equipped with guardrails, ensuring operator security while working at height. The sturdy construction of the Genie 1042 also contributes to stability, enabling users to focus on their tasks without worrying about the integrity of the lift.

Additionally, Genie has incorporated advanced technologies into the 1042 model, including a diagnostics system that provides real-time feedback on the machine's performance. This feature enhances maintenance efficiency, allowing operators to monitor the health of the platform and address potential issues proactively.

In summary, the Genie 1042 embodies a combination of height, outreach, and compactness, backed by reliable electric power, advanced safety features, and intelligent technology. Whether used in construction, maintenance, or any other sector requiring elevated work, the Genie 1042 proves to be a formidable tool that enhances productivity while prioritizing operator safety and environmental responsibility.