Genie 1042 manual 3b. Wiring pre-wired, Route Safe-T-Beamwires through wire guide

Page 18
Wire Nut
Insulated
Staple

3b. Wiring (pre-wired).

Route wire from wall to Safe-T-Beam®sensors (Fig. 4-5b).

Splice pre-wiring to shortened sensor wire, match wire pairs dash-to-dashand plain-to-plain.

-Trim sensor wire to approximately one foot (1 ft) from sensor.

-Split and strip ends of sensor wires and

pre-wired wires (Fig. 4-7).

- Splice wires together with (provided) wire nuts.

• Route wire from ceiling to power head (Fig. 4-5b).

Securely fasten wires where they exit wall and ceiling as you go.

– Use insulated staples.

– Staples should be snug only.

CAUTION

Staples which are too tight can cut or pinch wires. Cut or pinched wires can cause the Safe-T-Beam®System to stop working. When using the insulated staples, make sure you fasten them only as tightly as needed to hold the wire snugly.

4. Split and strip ends of sensor wires (Fig. 4-7).

NOTE: For rear cover locate Box 4.

5.Attach Safe-T-Beam®wire to power head wire terminal.

Route Safe-T-Beam®wires through wire guide.

Insert wire into terminal holes and lightly press in the orange locking clips above each terminal hole. (You can use a pencil or small screwdriver to comfortably reach in and lightly press down locking clips.) Insert white wires to 'even' numbered terminal holes and striped wires into 'odd' terminal holes (Fig. 4-8).

Locking

Clips Terminal

Holes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

5

 

4

 

3

 

2

 

1

 

 

Confirm wire lock by lightly tugging on the wire. The wire should remain in the terminal hole.

Install rear cover. The rear cover is the same color as the power head clips and body

(Fig. 4-9).

Do not install the white (lamp) cover at this time.

NOTE: Safe-T-Beam®alignment check must be performed following connection to electrical power (see page 19). DO NOT PLUG IN YET!

Wall

 

Wall

 

 

 

 

 

Red

Green

 

 

 

 

 

Source

Sensor

 

 

 

 

 

Ceiling

6 5

4 3

2 1

or

6 5

4 3

2 1

Power

Dashed Line = striped wire

Head

Solid Line = white wire

 

FIG. 4-5b Pre-Wired source and sensor wiring methods.

Wire

 

Insert Wire

 

Into Connector

 

 

Wire

 

 

Use this

 

 

wire routing

 

 

if NOT pre-wired

 

Invisible Light Beam

Sensor

 

 

Sensor

Protection Area

 

 

 

FIG. 4-6 Wire routing.

FIG. 4-7

Splitting and stripping.

2"

 

 

 

 

 

 

 

1/2"

 

 

 

 

 

 

6

5

4

3

2

1

FIG. 4-8

 

 

 

 

+ –

 

 

 

 

P

B

Insert wires.

InfaredSensor

 

 

 

(Power Head With Rear Cover Removed)

Cover clips

FIG. 4-9 Install rear cover.

18

PN# 36420Supplement, 10/27/2008

Image 18
Contents CHAINLIFT/BELTLIFT Models 1022/1024/1042 Keep people clear of opening while door is moving Turn OFF power before removing operator coverSystem technician using proper tools and instructions Do not allow children to play with the door operatorTable of Contents Opener FeaturesSafety Features Do not USE AN Extension Cord Typical Sectional Door Installation Pg PgRecommended Tools Parts Identification Not Shown Full SizeDo not Return to Point of Purchase Chain Piece Rail Hardware Assembled ViewImportant Installation Instructions Opener AssemblyChain Power Head & Rail Assembly Use 16-18 x 1/2 BoltsInstallation Header and Door Mounting Brackets Finding header bracket mounting locationDo not move door spring Mounting the header bracket Getting started Mounting the assemblyMounting the Opener Attach angle iron to beamsInstall Door Arms Door Bracket2b. Wiring If not pre-wired Wall Button Installation2a. Wiring If pre-wired Wall Button locationSecurely fasten wires Do not install rear cover yetMounting SAFE-T-BEAMSYSTEM Installation 3a. Wiring If not pre-wiredMounting Safe-T-BeamSource Red LED and Sensor Green LED 3b. Wiring pre-wired Route Safe-T-Beamwires through wire guideDo not install the white lamp cover at this time With Power Supplied Connecting to PowerWith Permanent Wiring With Grounded PlugSetting & Testing OPEN/CLOSE Limits Door LimitsClose Travel Limit Carriage Lock Keyed Emergency ReleaseKeyed Emergency Release Operation Instructions UP/DOWN Force Erase OPEN/CLOSE Travel LimitContact Reverse Test Programming Remote Controls Lost or Stolen RemoteVisor clip Light BULB/LENS InstallationBattery replacement Light bulbDoor balance MaintenanceRoutine Monthly Maintenance Contact reverseCircuit Wiring Diagram Advertencia AvertissementTroubleshooting Guide Operation Problem What to doTroubleshooting Guide Power Head LED Possible Problem SolutionTransmitter Compliance Statement Page This page left blank Solution Possible Problème ClignoteSolución Problema Posible Fonctionnement Dépannage DE Guide Funcionamiento DE Problema Averías DE Investigación DE Guía Del funcionamiento MalMantenimiento Avertissement MaintenanceAdvertencia Rutina DEAvertissement Viseur du clip le Fixer Visera de sujetador el Acople Lentille la FixerLente la Apriete Pile la’IC DE ET FCC LA DE Reglementation LA a Conforme Robado O Perdido RemotoRemotos Controles DE Programación BotónHAUT/BAS Force Inverso Contacto DE PruebaCerrar ABRIR/ DE Recorrido DEL Límite Borrar Puerta la de vano Del centro del debajo 4 xSecours DE Déverrouillage Avertissement AdvertenciaCLÉ CON Pestillo DE PicaporteABRIR/CERRAR AdvertenciaPuerta LA DE Límites Corredizo al cadena la EngranaInfrarroja Protección DE FunciónTension Sous Garde EN Mise Garde EN MisePrecaución PrecauciónCouvercle du Clips Arrière couvercle le InstallerPosterior tapa la Instale Tapa la de PresillasFuente y detector Del alambrado de Métodos Beam-T-Safe del Fuente y detector del LugaresSoportes Los a detectores los Acople Montaje de SoportesPuerta la de marco el Marque Montaje CoinçageMurale MontagePelando y Partiendo Pared DE Control DEL InstalaciónDénudage et Division Pared de control Del alambre de RecorridoPuerta LA DE Soporte ’OUVREUR DE Montage Installation InstalaciónCadena la de Ajuste Riel DEL10/27/2008 36420Supplement, PN# Control De caja la de Conjunto RielPartido riel del Conjunto Riel de partidas SeccionesPORTE-OUVRE pour rail de Ensemble ’OUVREUR Abridor DEL ConjuntoLa de l’ouvreur installer possible, du mesure la Dans De risque de d’AVERTISSEMENT l’étiquette PlacerAssemblée Pièce 1 À Rail DU Quincaillerie LA DE VUE Pieza 1 DE Riel DEL Herrajes DE Montaje DEL VistaMANQUANTES? Pièces Recommandés Outils Recomendadas Herramientas 14 .Pg 12 .Pg / .Pág11 .Pg / .Pág 18-17 .Pg OU / OElle-t-a section a garage de porte Votre Section la à reporter se installée fois uneAluminium, léger, acier en plaques des Section à référer Se .librement4 Secciones las a Refiérase Seguridad DE Características Matières DES TableÍndice Abridor DEL CaracterísticasTerre la à mis correctement être doit l’ouvreur Mobiles piècesMouvement Beltliftchainlift

1042 specifications

The Genie 1042 is a versatile and efficient aerial work platform designed to meet the demands of various industries, from construction to maintenance and operations. This compact boom lift is renowned for its remarkable lifting capabilities and user-friendly features, making it a favorite among professionals seeking reliability and performance.

One of the standout features of the Genie 1042 is its impressive working height, reaching up to 40 feet, and a horizontal outreach of 22 feet. This combination of height and reach makes it ideal for tasks that require working at significant elevations while still maintaining a solid base. The platform extends and retracts smoothly, providing operators with the flexibility to navigate around obstacles and access hard-to-reach areas effectively.

Powered by an efficient electric motor, the Genie 1042 operates quietly, making it suitable for indoor use and residential areas where noise restrictions may be a factor. The electric motor also offers zero emissions, aligning with modern environmental standards and preferences for greener equipment. Its compact design, with a width of just 4 feet, allows it to maneuver easily through standard doorways and tight spaces, enhancing its practicality on job sites.

Safety is a priority with the Genie 1042, featuring an intuitive operator control system and standard safety measures, including a tilt sensor and emergency stop buttons. The platform is equipped with guardrails, ensuring operator security while working at height. The sturdy construction of the Genie 1042 also contributes to stability, enabling users to focus on their tasks without worrying about the integrity of the lift.

Additionally, Genie has incorporated advanced technologies into the 1042 model, including a diagnostics system that provides real-time feedback on the machine's performance. This feature enhances maintenance efficiency, allowing operators to monitor the health of the platform and address potential issues proactively.

In summary, the Genie 1042 embodies a combination of height, outreach, and compactness, backed by reliable electric power, advanced safety features, and intelligent technology. Whether used in construction, maintenance, or any other sector requiring elevated work, the Genie 1042 proves to be a formidable tool that enhances productivity while prioritizing operator safety and environmental responsibility.