Genie 1042 manual SAFE-T-BEAMSYSTEM Installation, 3a. Wiring If not pre-wired

Page 17

4SAFE-T-BEAM®SYSTEM INSTALLATION

WARNING

There should be no electrical power to the opener while installing Safe-T-Beam®wires. If you have plugged in the power cord—UNPLUG IT NOW!

NOTE: The opener will not close the door automatically unless the Safe-T-Beam®System is installed.

NOTE: For Sensors, screws, wire, and insulated staples locate items and Bag 8 from Box 3.

1. Mounting brackets.

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM

mark

FIG. 4-1 Mark door frame.

• Mark both sides of garage door frame or wall no

higher than 6" and no lower than 5" above floor

(Fig. 4-1).

• Hold bracket against door frame or wall.

– Check if brackets extend out from wall far

enough, so tongue of bracket is beyond door,

tracks or any door hardware.

– If not:

a)

Mounting bracket extensions are available

 

through an authorized Genie® Dealer.

b)

Blocks of wood, etc. may be substituted for

 

extensions.

• Center bracket on your mark (Fig. 4-2).

• Fasten each with 2 screws (Fig. 4-2).

NOTE: Mounting brackets can be attached to the floor or concrete rim using concrete anchors (not provided).

center of

bracket

FIG. 4-2

Mounting brackets.

SUN

e

lid

s

bracket

tongue

FIG. 4-3 Attach sensors to brackets.

2.Mounting Safe-T-Beam®Source (Red LED) and Sensor (Green LED).

If garage has only one garage door.

Determine which side of garage receives most direct sunlight (Fig. 4-4).

Red LED should always be on sunny side whenever possible (Fig. 4-4).

For multiple doors.

Preventing crossed signals is critical.

Place source and sensor modules on adjacent doors facing in opposite directions (Fig. 4-4).

NOTE: To help prevent interference from sun, Safe-T-Beam®sensor with Green LED may be placed further away from the door opening, though extended no further out from the wall, where it will spend more time in shadow.

Slide source/sensor onto tongue of bracket until it clicks into place (Fig. 4-3).

3a. Wiring (If NOT pre-wired).

Route wire from Safe-T-Beam®sensors to power head using method shown in (Fig. 4-5a).

Securely fasten wires to wall and ceiling as you go (Fig. 4-6 on next page).

– Use insulated staples.

– Staples should be snug only.

Insulated

Staple

RED

GREEN

GREEN

RED RED

GREEN

LED

LED

LED

LED LED

LED

ONE DOOR

 

TWO DOOR

 

 

GARAGE

 

GARAGE

 

 

GREEN

RED RED

GREEN GREEN

RED

LED

LED LED

LED

LED

LED

THREE DOOR

GARAGE

FIG. 4-4 Safe-T-Beam®source and sensor

locations.

Red

Green

Source

Sensor

 

 

 

 

 

 

or

 

 

 

 

 

 

 

6 5 4 3 2 1

6 5 4 3 2 1

 

 

 

 

 

 

 

 

 

Dashed Line = striped wire

 

Power

 

Head

 

 

 

Solid Line = white wire

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 4-5a Source and sensor wiring methods.

PN# 36420Supplement, 10/27/2008

17

 

Image 17
Contents CHAINLIFT/BELTLIFT Models 1022/1024/1042 System technician using proper tools and instructions Turn OFF power before removing operator coverKeep people clear of opening while door is moving Do not allow children to play with the door operatorSafety Features Table of ContentsOpener Features Do not USE AN Extension Cord Pg Pg Typical Sectional Door InstallationParts Identification Not Shown Full Size Recommended ToolsDo not Return to Point of Purchase Piece Rail Hardware Assembled View ChainOpener Assembly Important Installation InstructionsChain Use 16-18 x 1/2 Bolts Power Head & Rail AssemblyDo not move door spring Mounting the header bracket Installation Header and Door Mounting BracketsFinding header bracket mounting location Mounting the Opener Mounting the assemblyGetting started Attach angle iron to beamsDoor Bracket Install Door Arms2a. Wiring If pre-wired Wall Button Installation2b. Wiring If not pre-wired Wall Button locationMounting Securely fasten wiresDo not install rear cover yet Mounting Safe-T-BeamSource Red LED and Sensor Green LED SAFE-T-BEAMSYSTEM Installation3a. Wiring If not pre-wired Do not install the white lamp cover at this time 3b. Wiring pre-wiredRoute Safe-T-Beamwires through wire guide With Permanent Wiring Connecting to PowerWith Power Supplied With Grounded PlugClose Travel Limit Setting & Testing OPEN/CLOSE LimitsDoor Limits Keyed Emergency Release Operation Instructions Carriage LockKeyed Emergency Release Contact Reverse Test UP/DOWN ForceErase OPEN/CLOSE Travel Limit Lost or Stolen Remote Programming Remote ControlsBattery replacement Light BULB/LENS InstallationVisor clip Light bulbRoutine Monthly Maintenance MaintenanceDoor balance Contact reverseAdvertencia Avertissement Circuit Wiring DiagramProblem What to do Troubleshooting Guide OperationPossible Problem Solution Troubleshooting Guide Power Head LEDTransmitter Compliance Statement Page This page left blank Clignote Solution Possible ProblèmeSolución Problema Posible Fonctionnement Dépannage DE Guide Del funcionamiento Mal Funcionamiento DE Problema Averías DE Investigación DE GuíaAdvertencia Avertissement MaintenanceMantenimiento Rutina DEAvertissement Lente la Apriete Lentille la FixerViseur du clip le Fixer Visera de sujetador el Acople Pile laRobado O Perdido Remoto ’IC DE ET FCC LA DE Reglementation LA a ConformeBotón Remotos Controles DE ProgramaciónCerrar ABRIR/ DE Recorrido DEL Límite Borrar Inverso Contacto DE PruebaHAUT/BAS Force Puerta la de vano Del centro del debajo 4 xCLÉ Avertissement AdvertenciaSecours DE Déverrouillage CON Pestillo DE PicaportePuerta LA DE Límites AdvertenciaABRIR/CERRAR Corredizo al cadena la EngranaTension Sous InfrarrojaProtección DE Función Precaución Garde EN MiseGarde EN Mise PrecauciónPosterior tapa la Instale Arrière couvercle le InstallerCouvercle du Clips Tapa la de PresillasBeam-T-Safe del Fuente y detector del Lugares Fuente y detector Del alambrado de MétodosPuerta la de marco el Marque Soportes Los a detectores los AcopleMontaje de Soportes Murale CoinçageMontaje MontageDénudage et Division Pared DE Control DEL InstalaciónPelando y Partiendo Pared de control Del alambre de RecorridoPuerta LA DE Soporte ’OUVREUR DE Montage Instalación Installation10/27/2008 36420Supplement, PN# Riel DELCadena la de Ajuste Control De caja la de Conjunto RielPORTE-OUVRE pour rail de Ensemble Partido riel del ConjuntoRiel de partidas Secciones Abridor DEL Conjunto ’OUVREURDe risque de d’AVERTISSEMENT l’étiquette Placer La de l’ouvreur installer possible, du mesure la DansPieza 1 DE Riel DEL Herrajes DE Montaje DEL Vista Assemblée Pièce 1 À Rail DU Quincaillerie LA DE VUEMANQUANTES? Pièces Recommandés Outils Recomendadas Herramientas 11 .Pg / .Pág 18-17 .Pg 12 .Pg / .Pág14 .Pg OU / OAluminium, léger, acier en plaques des Section la à reporter se installée fois uneElle-t-a section a garage de porte Votre Section à référer Se .librement4 Secciones las a Refiérase Índice Matières DES TableSeguridad DE Características Abridor DEL CaracterísticasMouvement Terre la à mis correctement être doit l’ouvreurMobiles pièces Beltliftchainlift

1042 specifications

The Genie 1042 is a versatile and efficient aerial work platform designed to meet the demands of various industries, from construction to maintenance and operations. This compact boom lift is renowned for its remarkable lifting capabilities and user-friendly features, making it a favorite among professionals seeking reliability and performance.

One of the standout features of the Genie 1042 is its impressive working height, reaching up to 40 feet, and a horizontal outreach of 22 feet. This combination of height and reach makes it ideal for tasks that require working at significant elevations while still maintaining a solid base. The platform extends and retracts smoothly, providing operators with the flexibility to navigate around obstacles and access hard-to-reach areas effectively.

Powered by an efficient electric motor, the Genie 1042 operates quietly, making it suitable for indoor use and residential areas where noise restrictions may be a factor. The electric motor also offers zero emissions, aligning with modern environmental standards and preferences for greener equipment. Its compact design, with a width of just 4 feet, allows it to maneuver easily through standard doorways and tight spaces, enhancing its practicality on job sites.

Safety is a priority with the Genie 1042, featuring an intuitive operator control system and standard safety measures, including a tilt sensor and emergency stop buttons. The platform is equipped with guardrails, ensuring operator security while working at height. The sturdy construction of the Genie 1042 also contributes to stability, enabling users to focus on their tasks without worrying about the integrity of the lift.

Additionally, Genie has incorporated advanced technologies into the 1042 model, including a diagnostics system that provides real-time feedback on the machine's performance. This feature enhances maintenance efficiency, allowing operators to monitor the health of the platform and address potential issues proactively.

In summary, the Genie 1042 embodies a combination of height, outreach, and compactness, backed by reliable electric power, advanced safety features, and intelligent technology. Whether used in construction, maintenance, or any other sector requiring elevated work, the Genie 1042 proves to be a formidable tool that enhances productivity while prioritizing operator safety and environmental responsibility.