IMPORTANT INSTALLATION INSTRUCTIONS

WARNING: Toreduce the risk of severe injury or death:

1.READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS. (If you have questions or do not understand an instruction, call The Genie Company or an authorized Genie® Dealer.)

2.Install only on a properly balanced sectional garage door. An improperly balanced door could cause severe injury. Have a trained door system technician make repairs or adjustments to cables, spring assemblies, and other hardware before installing the opener.

3.Remove all ropes and remove or make inoperative all locks connected to the garage door before installing opener.

4.Where possible, install the door opener 7 feet or more above the floor. For products having an emergency release, mount the emergency release 6 feet above the floor.

5.Do NOT connect the opener to source of power until instructed to do so.

6.Locate the control button:

Within sight of door,

At minimum height of 5 feet so small children are not able to reach it, and

Away from all moving parts of the door.

7.Install the Entrapment WARNING Label next to the control button in a prominent location. Install the Emergency Release Tag on or next to the emergency release.

8.After installing the opener, the door must reverse within 2 seconds when it contacts a 1-1/2 inch high object (or a 2 x 4 board laid flat) on the floor.

1OPENER ASSEMBLY

RAIL ASSEMBLY: Use a clean, flat surface.

NOTE: For 1-piece rail—skip to POWER HEAD &

RAIL ASSEMBLY.

WARNING

To reduce the risk of injury to persons or damage to property - Use this opener only with sectional doors.

CAUTION

Do NOT run until opener is fully assembled.

NOTE: Three (3) piece rail assemblies are for a 7 foot high door.

Clear a workspace area to unpack and organize box and contents for assembly.

1.There are 4 boxes inside the carton. Each box is numbered 1 - 4. Note that some openers will contain the same parts and be packaged with fewer boxes. Carefully remove the three internal boxes (Labeled #1, 2, and 3) and place them on the floor for easy access (Fig. 1-1).These boxes contain assembly parts and the contents are organized by assembly tasks. For quick reference inside the lid of each box there is a label illustrating the components inside.

2.Remove the motor power head and place it on the floor for later use. Remove box #4 and place it on the floor for later use.

FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM

 

 

 

#4

Bag 0

Rail Connectors

Bag 2

Header Bracket

 

 

 

Rail Connector Bolts

 

 

 

 

Header Bracket

 

 

 

Bolts

 

 

Rail Connector Nuts

 

 

 

 

 

Lag Srews

Bag 1

Bolts

Bag 3

 

Rail

 

 

 

5/16" Nuts

 

 

 

& Bolts

 

 

Power head

 

 

 

Box Label Example

 

FIG. 1-1

Internal boxes.

 

 

PN# 36420Supplement, 10/27/2008

9

 

Image 9
Contents CHAINLIFT/BELTLIFT Models 1022/1024/1042 System technician using proper tools and instructions Turn OFF power before removing operator coverKeep people clear of opening while door is moving Do not allow children to play with the door operatorTable of Contents Opener FeaturesSafety Features Do not USE AN Extension Cord Pg Pg Typical Sectional Door InstallationParts Identification Not Shown Full Size Recommended ToolsDo not Return to Point of Purchase Piece Rail Hardware Assembled View ChainOpener Assembly Important Installation InstructionsChain Use 16-18 x 1/2 Bolts Power Head & Rail AssemblyInstallation Header and Door Mounting Brackets Finding header bracket mounting locationDo not move door spring Mounting the header bracket Mounting the Opener Mounting the assemblyGetting started Attach angle iron to beamsDoor Bracket Install Door Arms2a. Wiring If pre-wired Wall Button Installation2b. Wiring If not pre-wired Wall Button locationSecurely fasten wires Do not install rear cover yetMounting SAFE-T-BEAMSYSTEM Installation 3a. Wiring If not pre-wiredMounting Safe-T-BeamSource Red LED and Sensor Green LED 3b. Wiring pre-wired Route Safe-T-Beamwires through wire guideDo not install the white lamp cover at this time With Permanent Wiring Connecting to PowerWith Power Supplied With Grounded PlugSetting & Testing OPEN/CLOSE Limits Door LimitsClose Travel Limit Carriage Lock Keyed Emergency ReleaseKeyed Emergency Release Operation Instructions UP/DOWN Force Erase OPEN/CLOSE Travel LimitContact Reverse Test Lost or Stolen Remote Programming Remote ControlsBattery replacement Light BULB/LENS InstallationVisor clip Light bulbRoutine Monthly Maintenance MaintenanceDoor balance Contact reverseAdvertencia Avertissement Circuit Wiring DiagramProblem What to do Troubleshooting Guide OperationPossible Problem Solution Troubleshooting Guide Power Head LEDTransmitter Compliance Statement Page This page left blank Clignote Solution Possible ProblèmeSolución Problema Posible Fonctionnement Dépannage DE Guide Del funcionamiento Mal Funcionamiento DE Problema Averías DE Investigación DE GuíaAdvertencia Avertissement MaintenanceMantenimiento Rutina DEAvertissement Lente la Apriete Lentille la FixerViseur du clip le Fixer Visera de sujetador el Acople Pile laRobado O Perdido Remoto ’IC DE ET FCC LA DE Reglementation LA a ConformeBotón Remotos Controles DE ProgramaciónCerrar ABRIR/ DE Recorrido DEL Límite Borrar Inverso Contacto DE PruebaHAUT/BAS Force Puerta la de vano Del centro del debajo 4 xCLÉ Avertissement AdvertenciaSecours DE Déverrouillage CON Pestillo DE PicaportePuerta LA DE Límites AdvertenciaABRIR/CERRAR Corredizo al cadena la EngranaInfrarroja Protección DE FunciónTension Sous Precaución Garde EN MiseGarde EN Mise PrecauciónPosterior tapa la Instale Arrière couvercle le InstallerCouvercle du Clips Tapa la de PresillasBeam-T-Safe del Fuente y detector del Lugares Fuente y detector Del alambrado de MétodosSoportes Los a detectores los Acople Montaje de SoportesPuerta la de marco el Marque Murale CoinçageMontaje MontageDénudage et Division Pared DE Control DEL InstalaciónPelando y Partiendo Pared de control Del alambre de RecorridoPuerta LA DE Soporte ’OUVREUR DE Montage Instalación Installation10/27/2008 36420Supplement, PN# Riel DELCadena la de Ajuste Control De caja la de Conjunto RielPartido riel del Conjunto Riel de partidas SeccionesPORTE-OUVRE pour rail de Ensemble Abridor DEL Conjunto ’OUVREURDe risque de d’AVERTISSEMENT l’étiquette Placer La de l’ouvreur installer possible, du mesure la DansPieza 1 DE Riel DEL Herrajes DE Montaje DEL Vista Assemblée Pièce 1 À Rail DU Quincaillerie LA DE VUEMANQUANTES? Pièces Recommandés Outils Recomendadas Herramientas 11 .Pg / .Pág 18-17 .Pg 12 .Pg / .Pág14 .Pg OU / OAluminium, léger, acier en plaques des Section la à reporter se installée fois uneElle-t-a section a garage de porte Votre Section à référer Se .librement4 Secciones las a Refiérase Índice Matières DES TableSeguridad DE Características Abridor DEL CaracterísticasTerre la à mis correctement être doit l’ouvreur Mobiles piècesMouvement Beltliftchainlift

1042 specifications

The Genie 1042 is a versatile and efficient aerial work platform designed to meet the demands of various industries, from construction to maintenance and operations. This compact boom lift is renowned for its remarkable lifting capabilities and user-friendly features, making it a favorite among professionals seeking reliability and performance.

One of the standout features of the Genie 1042 is its impressive working height, reaching up to 40 feet, and a horizontal outreach of 22 feet. This combination of height and reach makes it ideal for tasks that require working at significant elevations while still maintaining a solid base. The platform extends and retracts smoothly, providing operators with the flexibility to navigate around obstacles and access hard-to-reach areas effectively.

Powered by an efficient electric motor, the Genie 1042 operates quietly, making it suitable for indoor use and residential areas where noise restrictions may be a factor. The electric motor also offers zero emissions, aligning with modern environmental standards and preferences for greener equipment. Its compact design, with a width of just 4 feet, allows it to maneuver easily through standard doorways and tight spaces, enhancing its practicality on job sites.

Safety is a priority with the Genie 1042, featuring an intuitive operator control system and standard safety measures, including a tilt sensor and emergency stop buttons. The platform is equipped with guardrails, ensuring operator security while working at height. The sturdy construction of the Genie 1042 also contributes to stability, enabling users to focus on their tasks without worrying about the integrity of the lift.

Additionally, Genie has incorporated advanced technologies into the 1042 model, including a diagnostics system that provides real-time feedback on the machine's performance. This feature enhances maintenance efficiency, allowing operators to monitor the health of the platform and address potential issues proactively.

In summary, the Genie 1042 embodies a combination of height, outreach, and compactness, backed by reliable electric power, advanced safety features, and intelligent technology. Whether used in construction, maintenance, or any other sector requiring elevated work, the Genie 1042 proves to be a formidable tool that enhances productivity while prioritizing operator safety and environmental responsibility.