Table 13 Single-Phase Motor Specifications (60 Hz) 3450 rpm

TYPE

4" 2-WIRE

4" 3-WIRE

4" 3-WIRE W/CRC CB

4" 3-WIRE

6"

MOTOR

 

 

RATING

 

 

FULL

MAXIMUM

WINDING (1)

EFFICIENCY %

POWER

LOCKED

 

 

 

 

 

LOAD

(S.F. LOAD)

RES. IN OHMS

FACTOR %

KVA

MODEL

 

 

 

 

 

 

 

ROTOR

 

 

 

 

 

(2)

 

(2)

 

M=MAIN RES.

 

 

 

 

CODE

PREFIX

HP

KW

VOLTS

HZ

S.F.

WATTS

WATTS

S.F.

F.L.

S.F.

F.L.

AMPS

AMPS

AMPS

S=START RES.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

244504

1/2

0.37

115

60

1.6

10.0

670

12.0

960

1.0-1.3

62

56

73

58

64.4

R

244505

1/2

0.37

230

60

1.6

5.0

670

6.0

960

4.2-5.2

62

56

73

58

32.2

R

244507

3/4

0.55

230

60

1.5

6.8

940

8.0

1310

3.0-3.6

64

59

74

62

40.7

N

244508

1

0.75

230

60

1.4

8.2

1210

9.8

1600

2.2-2.7

65

62

74

63

48.7

N

244309

1.5

1.1

230

60

1.3

10.6

1700

13.1

2180

1.5-1.9

67

66

80

73

66.6

M

 

 

 

 

 

 

Y10.0

 

Y12.0

 

M1.0-1.3

 

 

 

 

 

 

214504

1/2

0.37

115

60

1.6

B10.0

670

B12.0

960

62

56

73

58

50.5

M

S4.1-5.1

 

 

 

 

 

 

R0

 

R0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y5.0

 

Y6.0

 

M4.2-5.2

 

 

 

 

 

 

214505

1/2

0.37

230

60

1.6

B5.0

670

B6.0

960

62

56

73

58

23

M

S16.7-20.5

 

 

 

 

 

 

R0

 

R0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y6.8

 

Y8.0

 

M3.0-3.6

 

 

 

 

 

 

214507

3/4

0.55

230

60

1.5

B6.8

940

B8.0

1310

64

59

74

62

34.2

M

S10.7-13.1

 

 

 

 

 

 

R0

 

R0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y8.2

 

Y9.8

 

M2.2-2.7

 

 

 

 

 

 

214508

1

0.75

230

60

1.4

B8.2

1210

B9.8

1600

65

62

74

63

41.8

L

S9.9-12.1

 

 

 

 

 

 

R0

 

R0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y3.6

 

Y4.3

 

M4.2-5.2

 

 

 

 

 

 

214505

1/2

0.37

230

60

1.6

B3.7

655

B4.0

890

67

57

90

81

23

M

S16.7-20.5

 

 

 

 

 

 

R2.0

 

R2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y4.9

 

Y5.7

 

M3.0-3.6

 

 

 

 

 

 

214507

3/4

0.55

230

60

1.5

B5.0

925

B5.2

1220

69

60

92

84

34.2

M

S10.7-13.1

 

 

 

 

 

 

R3.2

 

R3.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y6.0

 

Y7.1

 

M2.2-2.7

 

 

 

 

 

 

214508

1

0.75

230

60

1.4

B5.7

1160

B6.2

1490

70

64

92

86

41.8

L

S9.9-12.1

 

 

 

 

 

 

R3.4

 

R3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

214508

 

 

 

 

 

Y6.6

 

Y8.0

 

M2.2-2.7

 

 

 

 

 

 

W/1-

1

0.75

230

60

1.4

B6.6

1130

B7.9

1500

70

66

82

72

43

L

S9.9-12.1

1.5 CB

 

 

 

 

 

R1.3

 

R1.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y10.0

 

Y11.5

 

M1.7-2.2

 

 

 

 

 

 

224300

1.5

1.1

230

60

1.3

B9.9

1660

B11.0

2100

69

67

82

74

52

J

S8.0-9.7

 

 

 

 

 

 

R1.3

 

R1.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y10.0

 

Y13.2

 

M1.8-2.3

 

 

 

 

 

 

224301

2

1.5

230

60

1.25

B9.3

2060

B11.9

2610

71

73

95

93

51

G

S5.8-7.2

 

 

 

 

 

 

R2.6

 

R2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

224302

 

 

 

 

 

Y14.0

 

Y17.0

 

M1.0-1.5

 

 

 

 

 

 

3

2.2

230

60

1.15

B11.2

2940

B12.6

3350

77

76

97

97

83.5

H

(3)

S3.5-4.4

 

 

 

 

 

R6.1

 

R6.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

224303

 

 

 

 

 

Y23.0

 

Y27.5

 

M.68-1.0

 

 

 

 

 

 

5

3.7

230

60

1.15

B15.9

4920

B19.1

5620

76

76

100

100

121

F

(4)

S1.8-2.2

 

 

 

 

 

R11.0

 

R10.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

226110

 

 

 

 

 

Y23.0

 

Y27.5

 

M.55-.68

 

 

 

 

 

 

5

3.7

230

60

1.15

B14.3

4910

B17.4

5570

77

76

100

99

99

E

(5)

S1.3-1.7

 

 

 

 

 

R10.8

 

R10.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y36.5

 

Y42.1

 

M.36-.50

 

 

 

 

 

 

226111

7.5

5.5

230

60

1.15

B34.4

7300

B40.5

8800

73

74

91

90

165

F

S.88-1.1

 

 

 

 

 

 

R5.5

 

R5.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y44.0

 

Y51.0

 

M.27-.33

 

 

 

 

 

 

226112

10

7.5

230

60

1.15

B39.5

9800

B47.5

11300

76

77

96

96

204

E

S.80-.99

 

 

 

 

 

 

R9.3

 

R8.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y62.0

 

Y75.0

 

M.17-.22

 

 

 

 

 

 

226113

15

11

230

60

1.15

B52.0

13900

B62.5

16200

79

80

97

98

303

E

S.68-.93

 

 

 

 

 

 

R17.5

 

R16.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1)Main winding - yellow to black Start winding - yellow to red

(2)Y = Yellow lead - line amps

B = Black lead - main winding amps

R = Red lead - start or auxiliary winding amps

(3)Control Boxes date coded 02C and older have 35 MFD run capacitors. Current values should be Y14.0 @ FL and Y17.0 @ SF Load.

B12.2

B14.5

R4.7

R4.5

(4)Control Boxes date coded 01M and older have

60 MFD run capacitors and the current values on a 4" motor will be Y23.0 @ FL - Y27.5 @ SF Load.

B19.1 B23.2

R8.0 R7.8

(5)Control Boxes date coded 01M and older have

60 MFD run capacitors and the current values on a 6" motor will be Y23.0 @ FL -Y27.5 @ SF Load.

B18.2 B23.2

R8.0 R7.8

Performance is typical, not guaranteed, at specified voltages and specified capacitor values. Performance at voltage ratings not shown is similar, except amps vary inversely with voltage.

13

Image 16
Contents Submersible Motors Important Information for Installers of this Equipment Commitment to Quality Page Application Installation Maintenance Manual Submersible MotorsApplication All Motors StorageFrequency of Starts Mounting PositionTransformer Capacity Single-Phase or Three-Phase Effects of TorqueTransformer Capacity Torque Required ExamplesUse of Engine Driven Generators Single-Phase or Three-Phase Use of Check ValvesEngine Driven Generators KVAWater Temperature and Flow Flow Inducer SleeveRequired Cooling Flow MotorHead Loss From Flow Past Motor Hot Water Applications Standard MotorsHead Loss in Feet Meters at Various Flow Rates Minimum gpm l/m Required for 3 ft/s .91 m/sec Flow RateService Factor Horsepower Maximum Water TemperatureHot Water Applications Example Heat Factor Multiplier at 3 ft/s .91 m/sec Flow RateDrawdown Seals Grounding Control Boxes and PanelsGrounding Surge Arrestors Control Box and Panel Environment Application Single-Phase Motors Wire Control Boxes Wire Motor Solid State Controls QD Relays Solid State120 180200 250Two or More Different Cable Sizes Can Be Used Actual Length FormulaSingle-Phase Motor Specifications 60 Hz 3450 rpm Single-Phase Motor Fuse Sizing Buck-Boost Transformers Auxiliary Running CapacitorsBuck-Boost Transformer Sizing Application Three-Phase Motors Three-Phase 60 C Cable 140 220 150 240250 400 450150 200 250260 280Three-Phase 75 C Cable 120 180 130340 420 340 400 490Three-Phase Motor Specifications 60 Hz Full Load MaximumAmps Watts Efficiency % Locked Rotor AmpsThree-Phase Motor Fuse Sizing 575KW Volts Amps Watts Efficiency %100 150 200 175 250 225 125 110 300 17.5 Rating Full Load Maximum Efficiency Locked Rotor AmpsDual Element 60 Hz 4 Motors Heaters forOverload Relays Furnas60 Hz 6 Motors Nema Heaters for AdjustableFootnotes for Tables 28, 29, Submersible Pump Installation Check List Date Filled In By Motor PumpPower Supply TransformersControl Panel Incoming VoltageInstallation Controls and Protective DevicesVoltage To Motor Insulation CheckAmps To Motor Recommended Adjustable Overload Relays 60 Hz 8 MotorsSubMonitor Three-Phase Protection Power Factor CorrectionKVAR Required 60 Hz Motor Kvar Required for PFThree-Phase Starter Diagrams Line Voltage ControlThree-Phase Power Unbalance Checking and Correcting Rotation and Current UnbalanceThree-Phase Motor Lead Identification Phase ConvertersReduced Voltage Starters Inline Booster Pump SystemsFeed Water Temperature C AIR Franklin Cable chart See 12. WiringSource of Cable Ampacity Availability Variable Speed Submersible Pump Operation, Inverter Drives Installation All Motors Dimensions Standard Water WellTightening Motor Lead Connector Jam Nut Pump to Motor CouplingShaft Height and Free End Play Submersible Leads and CablesMaintenance All Motors System TroubleshootingMotor Does Not Start Motor Starts Too OftenMotor Runs Continuously Motor Runs But Overload Protector TripsPreliminary Tests All Sizes Single- and Three-Phase ResistanceResistance of Drop Cable ohms Insulation Resistance ReadingsNormal ohm and Megohm Values Between All Leads and Ground Single-Phase Control Boxes Checking and Repairing Procedures Power OnQD, Solid State Control Box Power Off Ohmmeter TestsOverload Kits 60 Hz QD Relay Replacement Kits QD Capacitor Replacement KitsQD Control Box Parts 60 Hz Control BOX Model no Capacitors MFD Volts Integral Horsepower Control Box Parts 60 HzOverload Relay Integral hp Capacitor Replacement Kits Integral hp Overload Replacement KitsIntegral hp Voltage Relay Replacement Kits Integral hp Contactor Replacement KitsControl Box Wiring Diagrams 1 hp QD RelayHp Standard Hp Deluxe 282 201 Hp X-LARGE Maintenance Electronic Products Pumptec-Plus Troubleshooting During InstallationPumptec-Plus Unit Appears DeadPumptec-Plus Troubleshooting After Installation QD Pumptec & Pumptec Troubleshooting QD Pumptec and PumptecSubDrive/MonoDrive Troubleshooting SubDrive75, 150, 300, MonoDrive, & MonoDrive XTSubMonitor Troubleshooting SubMonitorSubtrol-Plus Obsolete See SubMonitor Subtrol-Plus Troubleshooting After InstallationGreen Off Time Light on Abbreviations IgbtPage Page Page Toll Free Help from a Friend