Franklin 2007 manual KW Volts Amps Watts, Efficiency %

Page 27

Application – Three-Phase Motors

Table 24 Three-Phase Motor Specifications (60 Hz)

TYPE

MOTOR MODEL PREFIX

 

RATING

 

 

FULL LOAD

MAXIMUM

 

 

 

(S.F. LOAD)

 

 

 

 

 

HP

KW VOLTS

HZ

S.F.

AMPS WATTS

AMPS

WATTS

LINE TO LINE

EFFICIENCY %

LOCKED

RESISTANCE

ROTOR

 

 

OHMS

S.F.

F.L.

AMPS

KVA

CODE

6"

236650

236600

236660

236610

236620

236651

236601

236661

236611

236621

236652

236602

236662

236612

236622

236653

236603

236663

236613

236623

236654

236604

236664

236614

236624

236655

236605

236665

236615

236625

236656

236606

236666

236616

236626

236667

236617

236627

236668

236618

236628

236669

236619

236629

5

3.7

200

60

1.15

17.5

4700

20.0

5400

5

3.7

230

60

1.15

15

4700

17.6

5400

5

3.7

380

60

1.15

9.1

4700

10.7

5400

5

3.7

460

60

1.15

7.5

4700

8.8

5400

5

3.7

575

60

1.15

6

4700

7.1

5400

7.5

5.5

200

60

1.15

25.1

7000

28.3

8000

7.5

5.5

230

60

1.15

21.8

7000

24.6

8000

7.5

5.5

380

60

1.15

13.4

7000

15

8000

7.5

5.5

460

60

1.15

10.9

7000

12.3

8000

7.5

5.5

575

60

1.15

8.7

7000

9.8

8000

10

7.5

200

60

1.15

32.7

9400

37

10800

10

7.5

230

60

1.15

28.4

9400

32.2

10800

10

7.5

380

60

1.15

17.6

9400

19.6

10800

10

7.5

460

60

1.15

14.2

9400

16.1

10800

10

7.5

575

60

1.15

11.4

9400

12.9

10800

15

11

200

60

1.15

47.8

13700

54.4

15800

15

11

230

60

1.15

41.6

13700

47.4

15800

15

11

380

60

1.15

25.8

13700

28.9

15800

15

11

460

60

1.15

20.8

13700

23.7

15800

15

11

575

60

1.15

16.6

13700

19

15800

20

15

200

60

1.15

61.9

18100

69.7

20900

20

15

230

60

1.15

53.8

18100

60.6

20900

20

15

380

60

1.15

33

18100

37.3

20900

20

15

460

60

1.15

26.9

18100

30.3

20900

20

15

575

60

1.15

21.5

18100

24.2

20900

25

18.5

200

60

1.15

77.1

22500

86.3

25700

25

18.5

230

60

1.15

67

22500

75

25700

25

18.5

380

60

1.15

41

22500

46

25700

25

18.5

460

60

1.15

33.5

22500

37.5

25700

25

18.5

575

60

1.15

26.8

22500

30

25700

30

22

200

60

1.15

90.9

26900

104

31100

30

22

230

60

1.15

79

26900

90.4

31100

30

22

380

60

1.15

48.8

26900

55.4

31100

30

22

460

60

1.15

39.5

26900

45.2

31100

30

22

575

60

1.15

31.6

26900

36.2

31100

40

30

380

60

1.15

66.5

35600

74.6

42400

40

30

460

60

1.15

54.9

35600

61.6

42400

40

30

575

60

1.15

42.8

35600

49.6

42400

50

37

380

60

1.15

83.5

45100

95

52200

50

37

460

60

1.15

67.7

45100

77

52200

50

37

575

60

1.15

54.2

45100

61.6

52200

60

45

380

60

1.15

98.7

53500

111

61700

60

45

460

60

1.15

80.5

53500

91

61700

60

45

575

60

1.15

64.4

53500

72.8

61700

.77-.93

1.0-1.2

2.6-3.2

3.9-4.8

6.3-7.7

.43-.53

.64-.78

1.6-2.1

2.4-2.9

3.7-4.6

.37-.45

.47-.57

1.2-1.5

1.9-2.4

3.0-3.7

.24-.29

.28-.35

.77-.95

1.1-1.4

1.8-2.3

.16-.20

.22-.26

.55-.68

.8-1.0

1.3-1.6

.12-.15

.15-.19

.46-.56

.63-.77

1.0-1.3

.09-.11

.14-.17

.35-.43

.52-.64

.78-.95

.26-.33

.34-.42

.52-.64

.21-.25

.25-.32

.40-.49

.15-.18

.22-.27

.35-.39

79

79

79

79

79

80

80

80

80

80

79

79

79

79

79

81

81

81

81

81

82

82

82

82

82

83

83

83

83

83

83

83

83

83

83

83

83

83

82

82

82

84

84

84

79

79

79

79

79

80

80

80

80

80

79

79

79

79

79

81

81

81

81

81

82

82

82

82

82

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

83

84

84

84

99

86

52

43

34

150

130

79

65

52

198

172

104

86

69

306

266

161

133

106

416

362

219

181

145

552

480

291

240

192

653

568

317

284

227

481

397

318

501

414

331

627

518

414

H H H H H H H H H H H H H H H H H H H H J J J J J J J J J J J J J J J J J H H H H H H H

Model numbers above are for three-lead motors. Six-lead motors with different model numbers have the same running performance, but when wye connected for starting have locked rotor amps 33% of the values shown. Six-lead individual phase resistance = table X 1.5.

24

Image 27
Contents Submersible Motors Important Information for Installers of this Equipment Commitment to Quality Page Submersible Motors Application Installation Maintenance ManualMounting Position Application All MotorsStorage Frequency of StartsTorque Required Examples Transformer Capacity Single-Phase or Three-PhaseEffects of Torque Transformer CapacityKVA Use of Engine Driven Generators Single-Phase or Three-PhaseUse of Check Valves Engine Driven GeneratorsMotor Water Temperature and FlowFlow Inducer Sleeve Required Cooling FlowMinimum gpm l/m Required for 3 ft/s .91 m/sec Flow Rate Head Loss From Flow Past MotorHot Water Applications Standard Motors Head Loss in Feet Meters at Various Flow RatesHeat Factor Multiplier at 3 ft/s .91 m/sec Flow Rate Service Factor HorsepowerMaximum Water Temperature Hot Water Applications ExampleControl Box and Panel Environment Drawdown SealsGrounding Control Boxes and Panels Grounding Surge ArrestorsQD Relays Solid State Application Single-Phase MotorsWire Control Boxes Wire Motor Solid State Controls250 120180 200Actual Length Formula Two or More Different Cable Sizes Can Be UsedSingle-Phase Motor Specifications 60 Hz 3450 rpm Single-Phase Motor Fuse Sizing Auxiliary Running Capacitors Buck-Boost TransformersBuck-Boost Transformer Sizing Application Three-Phase Motors Three-Phase 60 C Cable 450 140 220150 240 250 400280 150200 250 260Three-Phase 75 C Cable 340 400 490 120 180130 340 420Efficiency % Locked Rotor Amps Three-Phase Motor Specifications 60 HzFull Load Maximum Amps Watts575 Three-Phase Motor Fuse SizingEfficiency % KW Volts Amps Watts100 150 200 175 250 225 125 110 300 17.5 Efficiency Locked Rotor Amps Rating Full Load MaximumDual Element Furnas 60 Hz 4 MotorsHeaters for Overload RelaysNema Heaters for Adjustable 60 Hz 6 MotorsFootnotes for Tables 28, 29, Submersible Pump Installation Check List Date Filled In By Pump MotorIncoming Voltage Power SupplyTransformers Control PanelControls and Protective Devices InstallationInsulation Check Voltage To MotorAmps To Motor 60 Hz 8 Motors Recommended Adjustable Overload RelaysMotor Kvar Required for PF SubMonitor Three-Phase ProtectionPower Factor Correction KVAR Required 60 HzLine Voltage Control Three-Phase Starter DiagramsChecking and Correcting Rotation and Current Unbalance Three-Phase Power UnbalancePhase Converters Three-Phase Motor Lead IdentificationInline Booster Pump Systems Reduced Voltage StartersFeed Water Temperature C Franklin Cable chart See 12. Wiring AIRSource of Cable Ampacity Availability Variable Speed Submersible Pump Operation, Inverter Drives Dimensions Standard Water Well Installation All MotorsSubmersible Leads and Cables Tightening Motor Lead Connector Jam NutPump to Motor Coupling Shaft Height and Free End PlayMotor Starts Too Often Maintenance All MotorsSystem Troubleshooting Motor Does Not StartMotor Runs But Overload Protector Trips Motor Runs ContinuouslyResistance Preliminary Tests All Sizes Single- and Three-PhaseInsulation Resistance Readings Resistance of Drop Cable ohmsNormal ohm and Megohm Values Between All Leads and Ground Checking and Repairing Procedures Power On Single-Phase Control BoxesOhmmeter Tests QD, Solid State Control Box Power OffQD Capacitor Replacement Kits Overload Kits 60 Hz QD Relay Replacement KitsQD Control Box Parts 60 Hz Integral Horsepower Control Box Parts 60 Hz Control BOX Model no Capacitors MFD VoltsOverload Relay Integral hp Contactor Replacement Kits Integral hp Capacitor Replacement KitsIntegral hp Overload Replacement Kits Integral hp Voltage Relay Replacement Kits1 hp QD Relay Control Box Wiring DiagramsHp Standard Hp Deluxe 282 201 Hp X-LARGE Unit Appears Dead Maintenance Electronic ProductsPumptec-Plus Troubleshooting During Installation Pumptec-PlusPumptec-Plus Troubleshooting After Installation QD Pumptec and Pumptec QD Pumptec & Pumptec TroubleshootingSubDrive75, 150, 300, MonoDrive, & MonoDrive XT SubDrive/MonoDrive TroubleshootingSubMonitor SubMonitor TroubleshootingSubtrol-Plus Troubleshooting After Installation Subtrol-Plus Obsolete See SubMonitorGreen Off Time Light on Igbt AbbreviationsPage Page Page Toll Free Help from a Friend