Franklin 2007 manual Integral Horsepower Control Box Parts 60 Hz, Overload Relay

Page 58

Maintenance Single-Phase Motors & Controls

Table 49 Integral Horsepower Control Box Parts 60 Hz

MOTOR

MOTOR

SIZE

RATING HP

CONTROL BOX (1)

MODEL NO.

CAPACITORS

PART NO. (2)

MFD.

VOLTS

QTY.

OVERLOAD (2)

PART NO.

RELAY (3)

CONTACTOR (2)

PART NO.

PART NO.

4"

1 - 1.5

STANDARD

 

4"

2

STANDARD

 

4"

2

DELUXE

 

4"

3

STANDARD

 

4"

3

DELUXE

 

4" & 6"

5

STANDARD

 

4" & 6"

5

DELUXE

 

6"

7.5

STANDARD

 

6"

7.5

DELUXE

 

6"

10

STANDARD

 

6"

10

STANDARD

 

6"

10

DELUXE

 

6"

10

DELUXE

 

6"

15

DELUXE

 

6"

15

DELUXE

 

6"

15

X-LARGE

 

282 300 8110

282 300 8610

282 301 8110

282 301 8310

282 302 8110

282 302 8310

282 113 8110

282 113 9310

282 201 9210

282 201 9310

282 202 9210

282 202 9230

282 202 9310

282 202 9330

282 203 9310

282 203 9330

282 203 9621

275 464 113 S

155 328 102 R

275 464 113 S

155 328 101 R

275 464 113 S

155 328 103 R

275 464 113 S

155 328 103 R

275 463 111 S

155 327 109 R

275 463 111 S

155 327 109 R

275 468 119 S

155 327 114 R

275 468 119 S

155 327 114 R

275 468 119 S

275 468 118 S

155 327 109 R

275 468 119 S

275 468 118 S

155 327 109 R

275 468 119 S

275468 120 S

155 327 102 R

275 463 120 S

275 468 118 S

275 468 119 S

155 327 102 R

275 468 119 S

275468 120 S

155 327 102 R

275 463 120 S

275 468 118 S

275 468 119 S

155 327 102 R

275 468 120 S

155 327 109 R

275 463 122 S

275 468 119 S

155 327 109 R

275 468 120 S

155 327 109 R

105-126 220

10 370

105-126 220

15 370

105-126 220

20 370

105-126 220

20 370

208-250 220

45 370

208-250 220

45 370

270-324 330

40 370

270-324 330

40 370

270-324 330

216-259 330

45 370

270-324 330

216-259 330

45 370

270-324 330

350-420 330

35 370

130-154 330

216-259 330

270-324 330

35 370

270-324 330

350-420 330

35 370

130-154 330

216-259 330

270-324 330

35 370

350-420 330

45 370

161-193 330

270-324 330

45 370

350-420 330

45 370

1

1

1

1

1

1

1

1

1

1

1

1

1

2

1

2

1

1

1

1

1

1

1

1

2

1

1

1

2

1

1

2

1

1

1

2

2

3

1

2

3

2

3

275 411 107

None

(See Note 4)

275 411 117 S

275 411 113 M

275 411 117 S

275 411 113 M

275 411 118 S

275 411 115 M

275 411 118 S

275 411 115 M

275 411 119 S

275 406 102 M

275 411 119 S

275 406 102 M

275 411 102 S

275 406 122 M

275 411 102 S

275 406 121 M

275 406 103 S

155 409 101 M

275 406 103 S

155 409 101 M

275 406 103 S

155 409 101 M

275 406 103 S

155 409 101 M

275 406 103 S

155 409 102 M

275 406 103 S

155 409 102 M

275 406 103 S

155 409 102 M

155 031 102

 

155 031 102

 

155 031 102

 

155 031 102

155 325 102 L

155 031 102

 

155 031 102

155 325 102 L

155 031 601

 

155 031 601

155 326 101 L

155 031 601

 

155 031 601

155 326 102 L

155 031 601

 

155 031 601

 

155 031 601

155 326 102 L

155 031 601

155 326 102 L

155 031 601

155 429 101 L

155 031 601

155 429 101 L

155 031 601

155 429 101 L

2 required

 

 

 

FOOTNOTES:

(1)Lightning arrestors 150 814 902 are suitable for all control boxes.

(2)S = Start, M = Main, L = Line, R = Run Deluxe = Control box with line contactor.

(3)For 208-volt systems or where line voltage is between 200 V and 210 V, a low voltage relay is required. On 3 hp and smaller control boxes use relay part 155 031 103 in place of 155 031 102 and use the next larger cable size than specifi ed in the 230 V table. On 5 hp and larger use relay 155 031 602 in place of 155 031 601 and next larger wire. Boost transformers per page 15 are an alternative to special relays and cable.

(4)Control box model 282 300 8610 is designed for use with motors having internal overload protectors. If used with a 1.5 hp motor manufactured prior to date code 06H18, Overload/Capacitor Kit 305 388 901 is required.

49

Image 58
Contents Submersible Motors Important Information for Installers of this Equipment Commitment to Quality Page Application Installation Maintenance Manual Submersible MotorsFrequency of Starts Application All MotorsStorage Mounting PositionTransformer Capacity Transformer Capacity Single-Phase or Three-PhaseEffects of Torque Torque Required ExamplesEngine Driven Generators Use of Engine Driven Generators Single-Phase or Three-PhaseUse of Check Valves KVARequired Cooling Flow Water Temperature and FlowFlow Inducer Sleeve MotorHead Loss in Feet Meters at Various Flow Rates Head Loss From Flow Past MotorHot Water Applications Standard Motors Minimum gpm l/m Required for 3 ft/s .91 m/sec Flow RateHot Water Applications Example Service Factor HorsepowerMaximum Water Temperature Heat Factor Multiplier at 3 ft/s .91 m/sec Flow RateGrounding Surge Arrestors Drawdown SealsGrounding Control Boxes and Panels Control Box and Panel EnvironmentWire Motor Solid State Controls Application Single-Phase MotorsWire Control Boxes QD Relays Solid State200 120180 250Two or More Different Cable Sizes Can Be Used Actual Length FormulaSingle-Phase Motor Specifications 60 Hz 3450 rpm Single-Phase Motor Fuse Sizing Buck-Boost Transformers Auxiliary Running CapacitorsBuck-Boost Transformer Sizing Application Three-Phase Motors Three-Phase 60 C Cable 250 400 140 220150 240 450260 150200 250 280Three-Phase 75 C Cable 340 420 120 180130 340 400 490Amps Watts Three-Phase Motor Specifications 60 HzFull Load Maximum Efficiency % Locked Rotor AmpsThree-Phase Motor Fuse Sizing 575KW Volts Amps Watts Efficiency %100 150 200 175 250 225 125 110 300 17.5 Rating Full Load Maximum Efficiency Locked Rotor AmpsDual Element Overload Relays 60 Hz 4 MotorsHeaters for Furnas60 Hz 6 Motors Nema Heaters for AdjustableFootnotes for Tables 28, 29, Submersible Pump Installation Check List Date Filled In By Motor PumpControl Panel Power SupplyTransformers Incoming VoltageInstallation Controls and Protective DevicesVoltage To Motor Insulation CheckAmps To Motor Recommended Adjustable Overload Relays 60 Hz 8 MotorsKVAR Required 60 Hz SubMonitor Three-Phase ProtectionPower Factor Correction Motor Kvar Required for PFThree-Phase Starter Diagrams Line Voltage ControlThree-Phase Power Unbalance Checking and Correcting Rotation and Current UnbalanceThree-Phase Motor Lead Identification Phase ConvertersReduced Voltage Starters Inline Booster Pump SystemsFeed Water Temperature C AIR Franklin Cable chart See 12. WiringSource of Cable Ampacity Availability Variable Speed Submersible Pump Operation, Inverter Drives Installation All Motors Dimensions Standard Water WellShaft Height and Free End Play Tightening Motor Lead Connector Jam NutPump to Motor Coupling Submersible Leads and CablesMotor Does Not Start Maintenance All MotorsSystem Troubleshooting Motor Starts Too OftenMotor Runs Continuously Motor Runs But Overload Protector TripsPreliminary Tests All Sizes Single- and Three-Phase ResistanceResistance of Drop Cable ohms Insulation Resistance ReadingsNormal ohm and Megohm Values Between All Leads and Ground Single-Phase Control Boxes Checking and Repairing Procedures Power OnQD, Solid State Control Box Power Off Ohmmeter TestsOverload Kits 60 Hz QD Relay Replacement Kits QD Capacitor Replacement KitsQD Control Box Parts 60 Hz Control BOX Model no Capacitors MFD Volts Integral Horsepower Control Box Parts 60 HzOverload Relay Integral hp Voltage Relay Replacement Kits Integral hp Capacitor Replacement KitsIntegral hp Overload Replacement Kits Integral hp Contactor Replacement KitsControl Box Wiring Diagrams 1 hp QD RelayHp Standard Hp Deluxe 282 201 Hp X-LARGE Pumptec-Plus Maintenance Electronic ProductsPumptec-Plus Troubleshooting During Installation Unit Appears DeadPumptec-Plus Troubleshooting After Installation QD Pumptec & Pumptec Troubleshooting QD Pumptec and PumptecSubDrive/MonoDrive Troubleshooting SubDrive75, 150, 300, MonoDrive, & MonoDrive XTSubMonitor Troubleshooting SubMonitorSubtrol-Plus Obsolete See SubMonitor Subtrol-Plus Troubleshooting After InstallationGreen Off Time Light on Abbreviations IgbtPage Page Page Toll Free Help from a Friend