Franklin 2007 manual Hp X-LARGE

Page 63

Maintenance Single-Phase Motors & Controls

START CAPACITOR

 

 

 

 

 

START CAPACITOR

 

 

ORG

 

 

 

 

 

BLK

ORG

 

 

 

 

BLK

 

START CAPACITOR

 

BLK

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

RED

 

 

 

 

RUN CAPACITOR

 

 

 

BLK

 

 

 

 

 

 

 

 

 

5

 

YEL

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

ORG

1

2

 

 

RED

 

 

 

 

 

 

 

 

 

 

SURGE

 

 

 

 

 

 

ARRESTOR

 

 

 

 

 

 

 

YEL

BLK

RED

 

GROUND

 

L1

L2

YEL

BLK

RED

 

 

 

 

 

 

 

 

LEAD

 

 

 

 

 

 

 

 

 

BLK

YEL

 

 

 

 

 

 

 

BLK

 

 

 

LINE POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

FROM TWO POLE

 

 

 

 

 

 

 

FUSED SWITCH OR

 

 

 

 

 

 

BLK

CIRCUIT BREAKER,

 

 

 

 

2

1

 

AND OTHER CONTROL

 

MAIN

 

 

 

 

GROUND

IF USED.

 

 

 

 

 

 

OVERLOAD

 

START

LEAD

 

 

 

 

 

 

 

 

 

 

OVERLOAD

TO

 

 

 

 

 

 

 

MOTOR

10 hp STANDARD

 

282 202 9210 or 282 202 9230

 

 

 

 

 

 

 

 

RUN CAPACITOR

START CAPACITOR

 

 

 

 

 

 

 

START CAPACITOR

BLK

 

 

 

BLK

 

 

 

 

 

 

 

 

 

RED

BLK

 

 

BLK

 

RED

 

 

 

 

 

RED

 

 

 

 

 

 

 

BLK

YEL

L2

 

T2

 

 

YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

COIL

 

 

 

 

 

 

 

L1

 

T1

 

 

BLK

 

 

BLK

 

 

 

 

 

 

ORG

 

5

YEL

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

1

2

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SURGE

 

 

 

 

 

 

 

ARRESTOR

 

 

 

 

 

 

 

 

RED

 

GROUND

 

SW

SW

L1

L2

RED

 

 

 

 

 

 

 

 

 

 

LEAD

 

 

 

 

 

 

 

 

LINE

 

 

 

YEL

 

 

 

 

 

 

 

 

 

 

 

POWER

 

BLK

 

 

 

BLK

 

FROM

 

 

 

 

 

 

 

 

 

 

 

1

BLK

 

TWO POLE

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

FUSED

TO

 

 

 

2

 

 

SWITCH

PRESSURE

MAIN

 

 

 

 

 

 

OR

OR OTHER

 

 

 

 

 

 

OVERLOAD

 

 

START

 

 

CIRCUIT

CONTROL

 

 

 

 

 

 

 

OVERLOAD

GROUND

TO

BREAKER

SWITCH

 

 

 

 

 

 

 

 

LEAD

MOTOR

 

 

 

 

 

 

 

15 hp DELUXE

282 203 9330 or 282 203 9330

 

 

 

 

 

 

 

 

 

START CAPACITOR

START CAPACITOR

ORG

ORG

 

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

 

 

BLK

RUN CAPACITOR

 

 

 

BLK

 

 

 

 

 

 

 

START CAPACITOR

 

 

 

 

 

 

 

BLK

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

RED

 

 

 

 

BLK

YEL

L2

 

 

T2

 

 

 

YEL

 

 

 

 

 

 

 

 

 

 

 

 

COIL

 

LINE

 

 

 

 

 

 

 

 

CONTACTOR

 

 

 

 

 

 

 

COIL

 

 

 

 

 

 

BLK

BLK

 

 

T1

 

 

 

BLK

 

 

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORG

 

 

5

 

YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

1

2

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YEL

 

 

 

SURGE

 

 

 

 

 

 

 

 

ARRESTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

GROUND

 

SW

SW

L1

L2

RED

 

 

 

LEAD

 

 

 

 

 

 

 

 

 

 

LINE

 

 

 

YEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

BLK

 

 

FROM

TO

 

 

 

 

 

1

BLK

 

TWO POLE

 

 

 

BLK

 

 

 

 

 

 

 

 

 

 

FUSED

PRESSURE

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

SWITCH

OR OTHER

 

MAIN

 

 

START

 

 

 

OR

CONTROL

 

 

 

 

 

 

 

OVERLOAD

 

 

OVERLOAD

 

 

 

CIRCUIT

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

TO

BREAKER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEAD

MOTOR

10 hp DELUXE

 

282 202 9230 or 282 202 9330

 

RUN CAPACITOR

 

 

 

 

 

 

 

START CAPACITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

5

 

 

 

 

 

RELAY

 

RELAY

 

L2

COIL

T2

 

1

2

1

2

SURGE

 

 

 

 

 

 

 

LINE CONTACTOR

 

 

 

 

 

ARRESTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

COIL

T1

 

 

 

 

 

 

 

 

 

 

 

 

L2

L1

 

 

 

 

 

 

 

GROUND LEAD

 

 

SW SW

B

Y

R

 

 

 

 

 

 

 

 

 

 

LINE

 

 

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

FROM

 

 

 

 

1

 

 

 

TWO POLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSED

 

 

 

 

2

 

 

 

SWITCH

TO

 

MAIN

 

 

 

 

GROUND

OR

 

 

 

 

 

PRESSURE

 

 

START

 

CIRCUIT

OVERLOAD

 

 

LEAD

OR OTHER

 

TO

BREAKER

 

 

OVERLOAD

 

CONTROL

 

 

 

 

 

MOTOR

 

SWITCH

 

 

 

 

 

 

 

 

15 hp X-LARGE

 

 

 

282 203 9621

54

Image 63
Contents Submersible Motors Important Information for Installers of this Equipment Commitment to Quality Page Submersible Motors Application Installation Maintenance ManualMounting Position Application All MotorsStorage Frequency of StartsTorque Required Examples Transformer Capacity Single-Phase or Three-PhaseEffects of Torque Transformer CapacityKVA Use of Engine Driven Generators Single-Phase or Three-PhaseUse of Check Valves Engine Driven GeneratorsMotor Water Temperature and FlowFlow Inducer Sleeve Required Cooling FlowMinimum gpm l/m Required for 3 ft/s .91 m/sec Flow Rate Head Loss From Flow Past MotorHot Water Applications Standard Motors Head Loss in Feet Meters at Various Flow RatesHeat Factor Multiplier at 3 ft/s .91 m/sec Flow Rate Service Factor HorsepowerMaximum Water Temperature Hot Water Applications ExampleControl Box and Panel Environment Drawdown SealsGrounding Control Boxes and Panels Grounding Surge ArrestorsQD Relays Solid State Application Single-Phase MotorsWire Control Boxes Wire Motor Solid State Controls250 120180 200Actual Length Formula Two or More Different Cable Sizes Can Be UsedSingle-Phase Motor Specifications 60 Hz 3450 rpm Single-Phase Motor Fuse Sizing Auxiliary Running Capacitors Buck-Boost TransformersBuck-Boost Transformer Sizing Application Three-Phase Motors Three-Phase 60 C Cable 450 140 220150 240 250 400280 150200 250 260Three-Phase 75 C Cable 340 400 490 120 180130 340 420Efficiency % Locked Rotor Amps Three-Phase Motor Specifications 60 HzFull Load Maximum Amps Watts575 Three-Phase Motor Fuse SizingEfficiency % KW Volts Amps Watts100 150 200 175 250 225 125 110 300 17.5 Efficiency Locked Rotor Amps Rating Full Load MaximumDual Element Furnas 60 Hz 4 MotorsHeaters for Overload RelaysNema Heaters for Adjustable 60 Hz 6 MotorsFootnotes for Tables 28, 29, Submersible Pump Installation Check List Date Filled In By Pump MotorIncoming Voltage Power SupplyTransformers Control PanelControls and Protective Devices InstallationInsulation Check Voltage To MotorAmps To Motor 60 Hz 8 Motors Recommended Adjustable Overload RelaysMotor Kvar Required for PF SubMonitor Three-Phase ProtectionPower Factor Correction KVAR Required 60 HzLine Voltage Control Three-Phase Starter DiagramsChecking and Correcting Rotation and Current Unbalance Three-Phase Power UnbalancePhase Converters Three-Phase Motor Lead IdentificationInline Booster Pump Systems Reduced Voltage StartersFeed Water Temperature C Franklin Cable chart See 12. Wiring AIRSource of Cable Ampacity Availability Variable Speed Submersible Pump Operation, Inverter Drives Dimensions Standard Water Well Installation All MotorsSubmersible Leads and Cables Tightening Motor Lead Connector Jam NutPump to Motor Coupling Shaft Height and Free End PlayMotor Starts Too Often Maintenance All MotorsSystem Troubleshooting Motor Does Not StartMotor Runs But Overload Protector Trips Motor Runs ContinuouslyResistance Preliminary Tests All Sizes Single- and Three-PhaseInsulation Resistance Readings Resistance of Drop Cable ohmsNormal ohm and Megohm Values Between All Leads and Ground Checking and Repairing Procedures Power On Single-Phase Control BoxesOhmmeter Tests QD, Solid State Control Box Power OffQD Capacitor Replacement Kits Overload Kits 60 Hz QD Relay Replacement KitsQD Control Box Parts 60 Hz Integral Horsepower Control Box Parts 60 Hz Control BOX Model no Capacitors MFD VoltsOverload Relay Integral hp Contactor Replacement Kits Integral hp Capacitor Replacement KitsIntegral hp Overload Replacement Kits Integral hp Voltage Relay Replacement Kits1 hp QD Relay Control Box Wiring DiagramsHp Standard Hp Deluxe 282 201 Hp X-LARGE Unit Appears Dead Maintenance Electronic ProductsPumptec-Plus Troubleshooting During Installation Pumptec-PlusPumptec-Plus Troubleshooting After Installation QD Pumptec and Pumptec QD Pumptec & Pumptec TroubleshootingSubDrive75, 150, 300, MonoDrive, & MonoDrive XT SubDrive/MonoDrive TroubleshootingSubMonitor SubMonitor TroubleshootingSubtrol-Plus Troubleshooting After Installation Subtrol-Plus Obsolete See SubMonitorGreen Off Time Light on Igbt AbbreviationsPage Page Page Toll Free Help from a Friend