Franklin 2007 manual Ohmmeter Tests, QD, Solid State Control Box Power Off

Page 56

Maintenance Single-Phase Motors & Controls

Ohmmeter Tests

QD, Solid State Control Box (Power Off)

A. START CAPACITOR AND RUN CAPACITOR IF APPLICABLE (CRC)

1.Meter Setting: R x 1,000.

2.Connections: Capacitor terminals.

3.Correct meter reading: Pointer should swing toward zero, then back to infi nity.

B.Q.D. (BLUE) RELAY

Step 1. Triac Test

1.Meter setting: R x 1,000.

2.Connections: Cap and B terminal.

3.Correct meter reading: Infi nity for all models.

Step 2. Coil Test

1.Meter Setting: R x 1.

2.Connections: L1 and B.

3.Correct meter reading: Zero ohms for all models.

C. POTENTIAL (VOLTAGE) RELAY

Step 1. Coil Test

1.Meter setting: R x 1,000.

2.Connections: #2 & #5.

3.Correct meter readings:

For 115 Volt Boxes:

0.7-1.8 (700 to 1,800 ohms).

For 230 Volt Boxes:

4.5-7.0 (4,500 to 7,000 ohms).

Step 2. Contact Test

1.Meter setting: R x 1.

2.Connections: #1 & #2.

3.Correct meter reading: Zero for all models.

Ohmmeter Tests

Integral Horsepower Control Box (Power Off)

A. OVERLOADS (Push Reset Buttons to make sure contacts are closed.)

1.Meter Setting: R x 1.

2.Connections: Overload terminals.

3.Correct meter reading: Less than 0.5 ohms.

B.CAPACITOR (Disconnect leads from one side of each capacitor before checking.)

1.Meter Setting: R x 1,000.

2.Connections: Capacitor terminals.

3.Correct meter reading: Pointer should swing toward zero, then drift back to infinity, except for capacitors with resistors which will drift back to 15,000 ohms.

C.POTENTIAL (VOLTAGE) RELAY Step 1. Coil Test

1.Meter setting: R x 1,000.

2.Connections: #2 & #5.

3.Correct meter readings: 4.5-7.0 (4,500 to 7,000 ohms) for all models.

Step 2. Contact Test

1.Meter Setting: R x 1.

2.Connections: #1 & #2.

3.Correct meter reading: Zero ohms for all models.

D.CONTACTOR Step 1. Coil

1.Meter setting: R x 100

2.Connections: Coil terminals

3.Correct meter reading:

1.8-14.0 (180 to 1,400 ohms)

Step 2. Contacts

1.Meter Setting: R X 1

2.Connections: L1 & T1 or L2 & T2

3.Manually close contacts

4.Correct meter reading: Zero ohms

CAUTION: The tests in this manual for components such as capacitors, relays, and QD switches should be regarded as indicative and not as conclusive. For example, a capacitor may test good (not open, not shorted) but may have lost some of its capacitance and may no longer be able to perform its function.

To verify proper operation of QD switches or relays, refer to operational test procedure described on page 46, Section B-2.

47

Image 56
Contents Submersible Motors Important Information for Installers of this Equipment Commitment to Quality Page Application Installation Maintenance Manual Submersible MotorsApplication All Motors StorageFrequency of Starts Mounting PositionTransformer Capacity Single-Phase or Three-Phase Effects of TorqueTransformer Capacity Torque Required ExamplesUse of Engine Driven Generators Single-Phase or Three-Phase Use of Check ValvesEngine Driven Generators KVAWater Temperature and Flow Flow Inducer SleeveRequired Cooling Flow MotorHead Loss From Flow Past Motor Hot Water Applications Standard MotorsHead Loss in Feet Meters at Various Flow Rates Minimum gpm l/m Required for 3 ft/s .91 m/sec Flow RateService Factor Horsepower Maximum Water TemperatureHot Water Applications Example Heat Factor Multiplier at 3 ft/s .91 m/sec Flow RateDrawdown Seals Grounding Control Boxes and PanelsGrounding Surge Arrestors Control Box and Panel EnvironmentApplication Single-Phase Motors Wire Control BoxesWire Motor Solid State Controls QD Relays Solid State120 180200 250Two or More Different Cable Sizes Can Be Used Actual Length FormulaSingle-Phase Motor Specifications 60 Hz 3450 rpm Single-Phase Motor Fuse Sizing Buck-Boost Transformer Sizing Auxiliary Running CapacitorsBuck-Boost Transformers Application Three-Phase Motors Three-Phase 60 C Cable 140 220 150 240250 400 450150 200 250260 280Three-Phase 75 C Cable 120 180 130340 420 340 400 490Three-Phase Motor Specifications 60 Hz Full Load MaximumAmps Watts Efficiency % Locked Rotor AmpsThree-Phase Motor Fuse Sizing 575KW Volts Amps Watts Efficiency %100 150 200 175 250 225 125 110 300 17.5 Rating Full Load Maximum Efficiency Locked Rotor AmpsDual Element 60 Hz 4 Motors Heaters forOverload Relays FurnasFootnotes for Tables 28, 29, Nema Heaters for Adjustable60 Hz 6 Motors Submersible Pump Installation Check List Date Filled In By Motor PumpPower Supply TransformersControl Panel Incoming VoltageInstallation Controls and Protective DevicesAmps To Motor Insulation CheckVoltage To Motor Recommended Adjustable Overload Relays 60 Hz 8 MotorsSubMonitor Three-Phase Protection Power Factor CorrectionKVAR Required 60 Hz Motor Kvar Required for PFThree-Phase Starter Diagrams Line Voltage ControlThree-Phase Power Unbalance Checking and Correcting Rotation and Current UnbalanceThree-Phase Motor Lead Identification Phase ConvertersReduced Voltage Starters Inline Booster Pump SystemsFeed Water Temperature C Source of Cable Ampacity Franklin Cable chart See 12. WiringAIR Availability Variable Speed Submersible Pump Operation, Inverter Drives Installation All Motors Dimensions Standard Water WellTightening Motor Lead Connector Jam Nut Pump to Motor CouplingShaft Height and Free End Play Submersible Leads and CablesMaintenance All Motors System TroubleshootingMotor Does Not Start Motor Starts Too OftenMotor Runs Continuously Motor Runs But Overload Protector TripsPreliminary Tests All Sizes Single- and Three-Phase ResistanceNormal ohm and Megohm Values Between All Leads and Ground Insulation Resistance ReadingsResistance of Drop Cable ohms Single-Phase Control Boxes Checking and Repairing Procedures Power OnQD, Solid State Control Box Power Off Ohmmeter TestsQD Control Box Parts 60 Hz QD Capacitor Replacement KitsOverload Kits 60 Hz QD Relay Replacement Kits Overload Relay Integral Horsepower Control Box Parts 60 HzControl BOX Model no Capacitors MFD Volts Integral hp Capacitor Replacement Kits Integral hp Overload Replacement KitsIntegral hp Voltage Relay Replacement Kits Integral hp Contactor Replacement KitsControl Box Wiring Diagrams 1 hp QD RelayHp Standard Hp Deluxe 282 201 Hp X-LARGE Maintenance Electronic Products Pumptec-Plus Troubleshooting During InstallationPumptec-Plus Unit Appears DeadPumptec-Plus Troubleshooting After Installation QD Pumptec & Pumptec Troubleshooting QD Pumptec and PumptecSubDrive/MonoDrive Troubleshooting SubDrive75, 150, 300, MonoDrive, & MonoDrive XTSubMonitor Troubleshooting SubMonitorGreen Off Time Subtrol-Plus Troubleshooting After InstallationSubtrol-Plus Obsolete See SubMonitor Light on Abbreviations IgbtPage Page Page Toll Free Help from a Friend