Table 48 QD Control Box Parts 60 Hz

HP

1/3

1/2

3/4

1

VOLTS

 

CONTROL BOX

QD (BLUE) RELAY

START

 

MFD

 

VOLTS

RUN

MFD

VOLTS

 

MODEL NUMBER

CAPACITOR

 

 

CAPACITOR

 

 

 

 

 

 

 

 

 

115

 

280 102 4915

 

275 464 125

 

159-191

 

110

 

 

 

 

223 415 905

 

 

 

 

 

230

 

280 103 4915

223 415 901

275 464 126

 

43-53

 

220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115

 

280 104 4915

223 415 906

275 464 201

 

250-300

 

125

 

 

 

230

 

280 105 4915

223 415 902

275 464 105

 

59-71

 

220

 

 

 

230

 

282 405 5015 (CRC)

223 415 912

275 464 126

 

43-53

 

220

156 362 101

15

370

 

 

 

 

 

 

 

 

 

 

 

 

230

 

280 107 4915

223 415 903

275 464 118

 

86-103

 

220

 

 

 

230

 

282 407 5015 (CRC)

223 415 913

275 464 105

 

59-71

 

220

156 362 102

23

370

 

 

 

 

 

 

 

 

 

 

 

 

230

 

280 108 4915

223 415 904

275 464 113

 

105-126

 

220

 

 

 

230

 

282 408 5015 (CRC)

223 415 914

275 464 118

 

86-103

 

220

156 362 102

23

370

 

 

 

 

 

 

 

 

 

 

 

 

NOTE 1: Control boxes supplied with QD Relays are designed to operate on 230 volt systems. For 208 volt

Table 48A QD Capacitor Replacement Kits

systems or where line voltage is between 200 volts and 210 volts use the next larger cable size, or use a boost transformer to raise the voltage.

NOTE 2: Voltage relays kits for 115 volts (305102901) and 230 volts (305102902) will replace current, voltage or QD Relays, and solid state switches.

CAPACITOR NUMBER

275 464 105

275 464 113

275 464 118

275 464 125

275 464 126

275 464 201

156 362 101

156 362 102

KIT

305 207 905

305 207 913

305 207 918

305 207 925

305 207 926

305 207 951

305 203 907

305 203 908

Table 48B Overload Kits 60 Hz

Table 48C QD Relay Replacement Kits

HP

1/3

1/3

1/2

1/2

3/4

1

VOLTS

115

230

115

230

230

230

KIT (1)

305 100 901

305 100 902

305 100 903

305 100 904

305 100 905

305 100 906

QD RELAY NUMBER

223 415 901

223 415 902

223 415 903

223 415 904

223 415 905

223 415 906

KIT

305 101 901

305 101 902

305 101 903

305 101 904

305 101 905

305 101 906

(1) For Control Boxes with model numbers that end with 4915.

223 415 912 (CRC)

223 415 913 (CRC)

223 415 914 (CRC)

305 105 901

305 105 902

305 105 903

48

Image 57
Contents Submersible Motors Important Information for Installers of this Equipment Commitment to Quality Page Submersible Motors Application Installation Maintenance ManualStorage Application All MotorsFrequency of Starts Mounting PositionEffects of Torque Transformer Capacity Single-Phase or Three-PhaseTransformer Capacity Torque Required ExamplesUse of Check Valves Use of Engine Driven Generators Single-Phase or Three-PhaseEngine Driven Generators KVAFlow Inducer Sleeve Water Temperature and FlowRequired Cooling Flow MotorHot Water Applications Standard Motors Head Loss From Flow Past MotorHead Loss in Feet Meters at Various Flow Rates Minimum gpm l/m Required for 3 ft/s .91 m/sec Flow RateMaximum Water Temperature Service Factor HorsepowerHot Water Applications Example Heat Factor Multiplier at 3 ft/s .91 m/sec Flow RateGrounding Control Boxes and Panels Drawdown SealsGrounding Surge Arrestors Control Box and Panel EnvironmentWire Control Boxes Application Single-Phase MotorsWire Motor Solid State Controls QD Relays Solid State180 120200 250Actual Length Formula Two or More Different Cable Sizes Can Be UsedSingle-Phase Motor Specifications 60 Hz 3450 rpm Single-Phase Motor Fuse Sizing Auxiliary Running Capacitors Buck-Boost TransformersBuck-Boost Transformer Sizing Application Three-Phase Motors Three-Phase 60 C Cable 150 240 140 220250 400 450200 250 150260 280Three-Phase 75 C Cable 130 120 180340 420 340 400 490Full Load Maximum Three-Phase Motor Specifications 60 HzAmps Watts Efficiency % Locked Rotor Amps575 Three-Phase Motor Fuse SizingEfficiency % KW Volts Amps Watts100 150 200 175 250 225 125 110 300 17.5 Efficiency Locked Rotor Amps Rating Full Load MaximumDual Element Heaters for 60 Hz 4 MotorsOverload Relays FurnasNema Heaters for Adjustable 60 Hz 6 MotorsFootnotes for Tables 28, 29, Submersible Pump Installation Check List Date Filled In By Pump MotorTransformers Power SupplyControl Panel Incoming VoltageControls and Protective Devices InstallationInsulation Check Voltage To MotorAmps To Motor 60 Hz 8 Motors Recommended Adjustable Overload RelaysPower Factor Correction SubMonitor Three-Phase ProtectionKVAR Required 60 Hz Motor Kvar Required for PFLine Voltage Control Three-Phase Starter DiagramsChecking and Correcting Rotation and Current Unbalance Three-Phase Power UnbalancePhase Converters Three-Phase Motor Lead IdentificationInline Booster Pump Systems Reduced Voltage StartersFeed Water Temperature C Franklin Cable chart See 12. Wiring AIRSource of Cable Ampacity Availability Variable Speed Submersible Pump Operation, Inverter Drives Dimensions Standard Water Well Installation All MotorsPump to Motor Coupling Tightening Motor Lead Connector Jam NutShaft Height and Free End Play Submersible Leads and CablesSystem Troubleshooting Maintenance All MotorsMotor Does Not Start Motor Starts Too OftenMotor Runs But Overload Protector Trips Motor Runs ContinuouslyResistance Preliminary Tests All Sizes Single- and Three-Phase Insulation Resistance Readings Resistance of Drop Cable ohms Normal ohm and Megohm Values Between All Leads and Ground Checking and Repairing Procedures Power On Single-Phase Control BoxesOhmmeter Tests QD, Solid State Control Box Power OffQD Capacitor Replacement Kits Overload Kits 60 Hz QD Relay Replacement KitsQD Control Box Parts 60 Hz Integral Horsepower Control Box Parts 60 Hz Control BOX Model no Capacitors MFD VoltsOverload Relay Integral hp Overload Replacement Kits Integral hp Capacitor Replacement KitsIntegral hp Voltage Relay Replacement Kits Integral hp Contactor Replacement Kits1 hp QD Relay Control Box Wiring DiagramsHp Standard Hp Deluxe 282 201 Hp X-LARGE Pumptec-Plus Troubleshooting During Installation Maintenance Electronic ProductsPumptec-Plus Unit Appears DeadPumptec-Plus Troubleshooting After Installation QD Pumptec and Pumptec QD Pumptec & Pumptec TroubleshootingSubDrive75, 150, 300, MonoDrive, & MonoDrive XT SubDrive/MonoDrive TroubleshootingSubMonitor SubMonitor TroubleshootingSubtrol-Plus Troubleshooting After Installation Subtrol-Plus Obsolete See SubMonitorGreen Off Time Light on Igbt AbbreviationsPage Page Page Toll Free Help from a Friend