Franklin 2007 manual Integral hp Capacitor Replacement Kits, Integral hp Overload Replacement Kits

Page 59

Maintenance Single-Phase Motors & Controls

Table 50 Integral hp Capacitor Replacement Kits

CAPACITOR NUMBER

275 463 122

275 463 111

275 463 120

275 464 113

275 468 117

275 468 118

275 468 119

275 468 120

155 327 101

155 327 102

155 327 109

155 327 114

155 328 101

155 328 102

155 328 103

KIT

305 206 912

305 206 911

305 206 920

305 207 913

305 208 917

305 208 918

305 208 919

305 208 920

305 203 901

305 203 902

305 203 909

305 203 914

305 204 901

305 204 902

305 204 903

Table 50A Integral hp Overload Replacement Kits

OVERLOAD NUMBER

275 406 102

275 406 103

275 406 121

275 406 122

275 411 102

275 411 107

275 411 108

275 411 113

275 411 115

275 411 117

275 411 118

275 411 119

KIT

305 214 902

305 214 903

305 214 921

305 214 922

305 215 902

305 215 907

305 215 908

305 215 913

305 215 915

305 215 917

305 215 918

305 215 919

Table 50B Integral hp Voltage Relay Replacement Kits

RELAY NUMBER

155 031 102

155 031 103

155 031 601

155 031 602

KIT

305 213 902

305 213 903

305 213 961

305 213 904

Table 50C Integral hp Contactor Replacement Kits

CONTACTOR

155 325 102

155 326 101

155 326 102

155 429 101

KIT

305 226 901

305 347 903

305 347 902

305 347 901

50

Image 59
Contents Submersible Motors Important Information for Installers of this Equipment Commitment to Quality Page Submersible Motors Application Installation Maintenance ManualMounting Position Application All MotorsStorage Frequency of StartsTorque Required Examples Transformer Capacity Single-Phase or Three-PhaseEffects of Torque Transformer CapacityKVA Use of Engine Driven Generators Single-Phase or Three-PhaseUse of Check Valves Engine Driven GeneratorsMotor Water Temperature and FlowFlow Inducer Sleeve Required Cooling FlowMinimum gpm l/m Required for 3 ft/s .91 m/sec Flow Rate Head Loss From Flow Past MotorHot Water Applications Standard Motors Head Loss in Feet Meters at Various Flow RatesHeat Factor Multiplier at 3 ft/s .91 m/sec Flow Rate Service Factor HorsepowerMaximum Water Temperature Hot Water Applications ExampleControl Box and Panel Environment Drawdown SealsGrounding Control Boxes and Panels Grounding Surge ArrestorsQD Relays Solid State Application Single-Phase MotorsWire Control Boxes Wire Motor Solid State Controls250 120180 200Actual Length Formula Two or More Different Cable Sizes Can Be UsedSingle-Phase Motor Specifications 60 Hz 3450 rpm Single-Phase Motor Fuse Sizing Buck-Boost Transformer Sizing Auxiliary Running CapacitorsBuck-Boost Transformers Application Three-Phase Motors Three-Phase 60 C Cable 450 140 220150 240 250 400280 150200 250 260Three-Phase 75 C Cable 340 400 490 120 180130 340 420Efficiency % Locked Rotor Amps Three-Phase Motor Specifications 60 HzFull Load Maximum Amps Watts575 Three-Phase Motor Fuse SizingEfficiency % KW Volts Amps Watts100 150 200 175 250 225 125 110 300 17.5 Efficiency Locked Rotor Amps Rating Full Load MaximumDual Element Furnas 60 Hz 4 MotorsHeaters for Overload RelaysFootnotes for Tables 28, 29, Nema Heaters for Adjustable60 Hz 6 Motors Submersible Pump Installation Check List Date Filled In By Pump MotorIncoming Voltage Power SupplyTransformers Control PanelControls and Protective Devices InstallationAmps To Motor Insulation CheckVoltage To Motor 60 Hz 8 Motors Recommended Adjustable Overload RelaysMotor Kvar Required for PF SubMonitor Three-Phase ProtectionPower Factor Correction KVAR Required 60 HzLine Voltage Control Three-Phase Starter DiagramsChecking and Correcting Rotation and Current Unbalance Three-Phase Power UnbalancePhase Converters Three-Phase Motor Lead IdentificationInline Booster Pump Systems Reduced Voltage StartersFeed Water Temperature C Source of Cable Ampacity Franklin Cable chart See 12. WiringAIR Availability Variable Speed Submersible Pump Operation, Inverter Drives Dimensions Standard Water Well Installation All MotorsSubmersible Leads and Cables Tightening Motor Lead Connector Jam NutPump to Motor Coupling Shaft Height and Free End PlayMotor Starts Too Often Maintenance All MotorsSystem Troubleshooting Motor Does Not StartMotor Runs But Overload Protector Trips Motor Runs ContinuouslyResistance Preliminary Tests All Sizes Single- and Three-PhaseNormal ohm and Megohm Values Between All Leads and Ground Insulation Resistance ReadingsResistance of Drop Cable ohms Checking and Repairing Procedures Power On Single-Phase Control BoxesOhmmeter Tests QD, Solid State Control Box Power OffQD Control Box Parts 60 Hz QD Capacitor Replacement KitsOverload Kits 60 Hz QD Relay Replacement Kits Overload Relay Integral Horsepower Control Box Parts 60 HzControl BOX Model no Capacitors MFD Volts Integral hp Contactor Replacement Kits Integral hp Capacitor Replacement KitsIntegral hp Overload Replacement Kits Integral hp Voltage Relay Replacement Kits1 hp QD Relay Control Box Wiring DiagramsHp Standard Hp Deluxe 282 201 Hp X-LARGE Unit Appears Dead Maintenance Electronic ProductsPumptec-Plus Troubleshooting During Installation Pumptec-PlusPumptec-Plus Troubleshooting After Installation QD Pumptec and Pumptec QD Pumptec & Pumptec TroubleshootingSubDrive75, 150, 300, MonoDrive, & MonoDrive XT SubDrive/MonoDrive TroubleshootingSubMonitor SubMonitor TroubleshootingGreen Off Time Subtrol-Plus Troubleshooting After InstallationSubtrol-Plus Obsolete See SubMonitor Light on Igbt AbbreviationsPage Page Page Toll Free Help from a Friend