Franklin 2007 Three-Phase Motor Specifications 60 Hz, Full Load Maximum, Amps Watts, KVA Code

Page 25

Application – Three-Phase Motors

Table 22 Three-Phase Motor Specifications (60 Hz)

TYPE

4"

MOTOR MODEL PREFIX

234501

234511

234541

234521

234502

234512

234542

234522

234503

234513

234543

234523

234504

234514

234544

234524

234534

234305

234315

234345

234325

234335

234306

234316

234346

234326

234336

234307

234317

234347

234327

234337

234308

234318

234348

234328

234338

234549

234595

234598

 

 

RATING

 

 

 

FULL LOAD

 

MAXIMUM

 

 

 

 

 

 

(S.F. LOAD)

 

 

 

 

 

 

 

 

 

 

 

HP

KW

 

VOLTS

HZ

S.F.

 

AMPS

 

WATTS

 

AMPS

 

WATTS

1/2

0.37

200

 

1.6

 

2.8

 

585

 

3.4

 

860

60

 

 

 

 

1/2

0.37

230

60

1.6

 

2.4

 

585

 

2.9

 

860

1/2

0.37

380

60

1.6

 

1.4

 

585

 

2.1

 

860

1/2

0.37

460

60

1.6

 

1.2

 

585

 

1.5

 

860

3/4

0.55

200

60

1.5

 

3.6

 

810

 

4.4

 

1150

3/4

0.55

230

60

1.5

 

3.1

 

810

 

3.8

 

1150

3/4

0.55

380

60

1.5

 

1.9

 

810

 

2.5

 

1150

3/4

0.55

460

60

1.5

 

1.6

 

810

 

1.9

 

1150

1

0.75

200

60

1.4

 

4.5

 

1070

 

5.4

 

1440

1

0.75

230

60

1.4

 

3.9

 

1070

 

4.7

 

1440

1

0.75

380

60

1.4

 

2.3

 

1070

 

2.8

 

1440

1

0.75

460

60

1.4

 

2

 

1070

 

2.4

 

1440

1.5

1.1

200

60

1.3

 

5.8

 

1460

 

6.8

 

1890

1.5

1.1

230

60

1.3

 

5

 

1460

 

5.9

 

1890

1.5

1.1

380

60

1.3

 

3

 

1460

 

3.6

 

1890

1.5

1.1

460

60

1.3

 

2.5

 

1460

 

3.1

 

1890

1.5

1.1

575

60

1.3

 

2

 

1460

 

2.4

 

1890

2

1.5

200

60

1.25

 

7.7

 

2150

 

9.3

 

2700

2

1.5

230

60

1.25

 

6.7

 

2150

 

8.1

 

2700

2

1.5

380

60

1.25

 

4.1

 

2150

 

4.9

 

2700

2

1.5

460

60

1.25

 

3.4

 

2150

 

4.1

 

2700

2

1.5

575

60

1.25

 

2.7

 

2150

 

3.2

 

2700

3

2.2

200

60

1.15

 

10.9

 

2980

 

12.5

 

3420

3

2.2

230

60

1.15

 

9.5

 

2980

 

10.9

 

3420

3

2.2

380

60

1.15

 

5.8

 

2980

 

6.6

 

3420

3

2.2

460

60

1.15

 

4.8

 

2980

 

5.5

 

3420

3

2.2

575

60

1.15

 

3.8

 

2980

 

4.4

 

3420

5

3.7

200

60

1.15

 

18.3

 

5050

 

20.5

 

5810

5

3.7

230

60

1.15

 

15.9

 

5050

 

17.8

 

5810

5

3.7

380

60

1.15

 

9.6

 

5050

 

10.8

 

5810

5

3.7

460

60

1.15

 

8

 

5050

 

8.9

 

5810

5

3.7

575

60

1.15

 

6.4

 

5050

 

7.1

 

5810

7.5

5.5

200

60

1.15

 

26.5

 

7360

 

30.5

 

8450

7.5

5.5

230

60

1.15

 

23

 

7360

 

26.4

 

8450

7.5

5.5

380

60

1.15

 

13.9

 

7360

 

16

 

8450

7.5

5.5

460

60

1.15

 

11.5

 

7360

 

13.2

 

8450

7.5

5.5

575

60

1.15

 

9.2

 

7360

 

10.6

 

8450

10

7.5

380

60

1.15

 

19.3

 

10000

 

21

 

11400

10

7.5

460

60

1.15

 

15.9

 

10000

 

17.3

 

11400

10

7.5

 

575

60

1.15

 

12.5

 

10000

 

13.6

 

11400

LINE TO LINE RESISTANCE OHMS

6.6-8.4

9.5-10.9

23.2-28.6

38.4-44.1

4.6-5.9

6.8-7.8

16.6-20.3

27.2-30.9

3.8-4.5

4.9-5.6

12.2-14.9

19.9-23.0

2.5-3.0

3.2-4.0

8.5-10.4

13.0-16.0

20.3-25.0

1.8-2.4

2.3-3.0

6.6-8.2

9.2-12.0

14.6-18.7

1.3-1.7

1.8-2.2

4.7-6.0

7.2-8.8

11.4-13.9

.74-.91

1.0-1.2

2.9-3.6

4.0-4.9

6.4-7.8

.46-.57

.61-.75

1.6-2.0

2.5-3.1

4.0-5.0

1.2-1.6

1.8-2.3

2.8-3.5

EFFICIENCY %

S.F.

F.L.

70

64

70

64

70

64

70

64

73

69

73

69

73

69

73

69

72

70

72

70

72

70

72

70

76

76

76

76

76

76

76

76

76

76

69

69

69

69

69

69

69

69

69

69

75

75

75

75

75

75

75

75

75

75

74

74

74

74

74

74

74

74

74

74

76

76

76

76

76

76

76

76

76

76

75

75

7575

7575

LOCKED

ROTOR

AMPS

17.5

15.2

9.2

7.6

23.1

20.1

12.2

10.7

30.9

26.9

16.3

13.5

38.2

33.2

20.1

16.6

13.3

53.6

46.6

28.2

23.3

18.6

71.2

61.9

37.5

31

24.8

122

106

64.4

53.2

42.6

188

164

99.1

81.9

65.5

140

116

92.8

KVA

CODE

N

N

N

N

M

M

M

M

M

M

M

M

K

K

K

K

K

L

L

L

L

L

K

K

K

K

K

K

K

K

K

K

K

K

K

K

K

L

L

L

22

Image 25
Contents Submersible Motors Important Information for Installers of this Equipment Commitment to Quality Page Submersible Motors Application Installation Maintenance ManualStorage Application All MotorsFrequency of Starts Mounting PositionEffects of Torque Transformer Capacity Single-Phase or Three-PhaseTransformer Capacity Torque Required ExamplesUse of Check Valves Use of Engine Driven Generators Single-Phase or Three-PhaseEngine Driven Generators KVAFlow Inducer Sleeve Water Temperature and FlowRequired Cooling Flow MotorHot Water Applications Standard Motors Head Loss From Flow Past MotorHead Loss in Feet Meters at Various Flow Rates Minimum gpm l/m Required for 3 ft/s .91 m/sec Flow RateMaximum Water Temperature Service Factor HorsepowerHot Water Applications Example Heat Factor Multiplier at 3 ft/s .91 m/sec Flow RateGrounding Control Boxes and Panels Drawdown SealsGrounding Surge Arrestors Control Box and Panel EnvironmentWire Control Boxes Application Single-Phase MotorsWire Motor Solid State Controls QD Relays Solid State180 120200 250Actual Length Formula Two or More Different Cable Sizes Can Be UsedSingle-Phase Motor Specifications 60 Hz 3450 rpm Single-Phase Motor Fuse Sizing Buck-Boost Transformers Auxiliary Running CapacitorsBuck-Boost Transformer Sizing Application Three-Phase Motors Three-Phase 60 C Cable 150 240 140 220250 400 450 200 250 150 260 280Three-Phase 75 C Cable 130 120 180340 420 340 400 490Full Load Maximum Three-Phase Motor Specifications 60 HzAmps Watts Efficiency % Locked Rotor Amps575 Three-Phase Motor Fuse SizingEfficiency % KW Volts Amps Watts100 150 200 175 250 225 125 110 300 17.5 Efficiency Locked Rotor Amps Rating Full Load MaximumDual Element Heaters for 60 Hz 4 MotorsOverload Relays Furnas60 Hz 6 Motors Nema Heaters for AdjustableFootnotes for Tables 28, 29, Submersible Pump Installation Check List Date Filled In By Pump MotorTransformers Power SupplyControl Panel Incoming VoltageControls and Protective Devices InstallationVoltage To Motor Insulation CheckAmps To Motor 60 Hz 8 Motors Recommended Adjustable Overload RelaysPower Factor Correction SubMonitor Three-Phase ProtectionKVAR Required 60 Hz Motor Kvar Required for PFLine Voltage Control Three-Phase Starter DiagramsChecking and Correcting Rotation and Current Unbalance Three-Phase Power UnbalancePhase Converters Three-Phase Motor Lead IdentificationInline Booster Pump Systems Reduced Voltage StartersFeed Water Temperature C AIR Franklin Cable chart See 12. WiringSource of Cable Ampacity Availability Variable Speed Submersible Pump Operation, Inverter Drives Dimensions Standard Water Well Installation All MotorsPump to Motor Coupling Tightening Motor Lead Connector Jam NutShaft Height and Free End Play Submersible Leads and CablesSystem Troubleshooting Maintenance All MotorsMotor Does Not Start Motor Starts Too OftenMotor Runs But Overload Protector Trips Motor Runs ContinuouslyResistance Preliminary Tests All Sizes Single- and Three-PhaseResistance of Drop Cable ohms Insulation Resistance ReadingsNormal ohm and Megohm Values Between All Leads and Ground Checking and Repairing Procedures Power On Single-Phase Control BoxesOhmmeter Tests QD, Solid State Control Box Power OffOverload Kits 60 Hz QD Relay Replacement Kits QD Capacitor Replacement KitsQD Control Box Parts 60 Hz Control BOX Model no Capacitors MFD Volts Integral Horsepower Control Box Parts 60 HzOverload Relay Integral hp Overload Replacement Kits Integral hp Capacitor Replacement KitsIntegral hp Voltage Relay Replacement Kits Integral hp Contactor Replacement Kits1 hp QD Relay Control Box Wiring DiagramsHp Standard Hp Deluxe 282 201 Hp X-LARGE Pumptec-Plus Troubleshooting During Installation Maintenance Electronic ProductsPumptec-Plus Unit Appears DeadPumptec-Plus Troubleshooting After Installation QD Pumptec and Pumptec QD Pumptec & Pumptec TroubleshootingSubDrive75, 150, 300, MonoDrive, & MonoDrive XT SubDrive/MonoDrive TroubleshootingSubMonitor SubMonitor TroubleshootingSubtrol-Plus Obsolete See SubMonitor Subtrol-Plus Troubleshooting After InstallationGreen Off Time Light on Igbt AbbreviationsPage Page Page Toll Free Help from a Friend