198 CHAPTER 16: MANAGING SYSTEM LOGS
The Logging Setup Page contains the following fields:
■Enable Local Logging — Specifies if device local logs for Cache and
servers are enabled. Console logs are enabled by default.
■Severity level — Specifies the minimum severity level for which a
message will be logged. When a severity level is selected, all severity
level choices above the selection are selected automatically. The
possible field values are:
■Emergency — The highest warning level. If the device is down or
not functioning properly, an emergency log message is saved to
the specified logging location.
■Alert — The second highest warning level. An alert log is saved, if
there is a serious device malfunction; for example, all device
features are down.
■Critical — The third highest warning level. A critical log is saved if a
critical device malfunction occurs; for example, two device ports
are not functioning, while the rest of the device ports remain
functional.
■Error — A device error has occurred, for example, if a single port is
offline.
■Warning — The lowest level of a device warning. The device is
functioning, but an operational problem has occurred.
■Notice — Provides device information.
■Info — Provides device information.
■Debug — Provides debugging messages.
■Not Active — Provides no messages.