24CHAPTER 1: GETTING STARTED

Connecting the Workstation to the Switch

1Connect the workstation to the console port using the console cable as shown in Figure 5.

Figure 5 Connecting a Workstation to the Switch using the Console Port

Workstation

(with terminal emulationSwitch software installed)

Console Port

Connection

Console Cable

Manually set the IP Address using the Console Port

To connect the cable:

aAttach the cable’s RJ-45 connector to the Console port of the switch.

bAttach the other end of the cable to the workstation.

2Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings must be set to match the default settings for the switch, which are:

38,400 baud (bits per second)

8 data bits

no parity

1 stop bit

no hardware flow control

Refer to the documentation that accompanies the terminal emulation software for more information.

3Power up the switch. The Power on Self Test (POST) will be performed. The Switch 2924-PWR takes approximately one minute to boot.

You are now ready to manually set up the switch with IP information using the command line interface.

You need to have the following information:

IP address

subnet mask

default gateway

Page 24
Image 24
3Com 2924-PWR manual Connecting the Workstation to the Switch, Manually set the IP Address using the Console Port