Displaying Switch Hardware/Software Versions 4

CLI – Specify the hostname, location and contact information.

Console(config)#hostname R&D 5

34-1

Console(config)#snmp-server location WC 9

40-4

Console(config)#snmp-server contact Ted

40-4

Console(config)#exit

 

 

Console#show system

 

 

34-7

 

 

System Description: 24/48 L2/L4 IPV4/IPV6 GE Switch

 

System OID String: 1.3.6.1.4.1.259.6.10.95

 

System Information

 

 

System Up Time:

0 days, 1 hours, 28 minutes, and 0.51 seconds

System Name:

R&D 5

 

System Location:

WC 9

 

System Contact:

Ted

 

MAC Address (Unit1):

00-12-34-56-78-9A

 

Web Server:

Enabled

 

Web Server Port:

80

 

Web Secure Server:

Enabled

 

Web Secure Server Port:

443

 

Telnet Server:

Enable

 

Telnet Server Port:

23

 

Authentication Login:

Local RADIUS None

 

Jumbo Frame:

Disabled

 

POST Result:

 

 

DUMMY Test

1 ................. PASS

DRAM Test .................... PASS

Timer Test

................... PASS

PCI Device

1 Test ............ PASS

I2C Bus Initialization ....... PASS

Switch Int

Loopback Test ..... PASS

Fan Speed Test

............... PASS

Done All

Pass.

 

Console#

 

 

Displaying Switch Hardware/Software Versions

Use the Switch Information page to display hardware/firmware version numbers for the main board and management software, as well as the power status of the system.

Field Attributes

Main Board

Serial Number – The serial number of the switch.

Number of Ports – Number of built-in ports.

Hardware Version – Hardware version of the main board.

Internal Power Status – Displays the status of the internal power supply.

Management Software

EPLD Version – Version number of EEPROM Programmable Logic Device.

Loader Version – Version number of loader code.

4-3

Page 63
Image 63
Accton Technology ES4548D, ES4524D manual Displaying Switch Hardware/Software Versions, Main Board, Management Software