Accton Technology ES4524D manual Syntax Logging trap level no logging trap, Disabled Level 7

Models: ES4524D 24/48-Port ES4548D

1 588
Download 588 pages 58.05 Kb
Page 322
Image 322

37 Event Logging Commands

Command Usage

The command specifies the facility type tag sent in syslog messages. (See RFC 3164.) This type has no effect on the kind of messages reported by the switch. However, it may be used by the syslog server to sort messages or to store messages in the corresponding database.

Example

Console(config)#logging facility 19

Console(config)#

logging trap

This command enables the logging of system messages to a remote server, or limits the syslog messages saved to a remote server based on severity. Use this command without a specified level to enable remote logging. Use the no form to disable remote logging.

Syntax

logging trap [level] no logging trap

level - One of the syslog severity levels listed in the table on page 37-2.Messages sent include the selected level up through level 0.

Default Setting

Disabled

Level 7 - 0

Command Mode

Global Configuration

Command Usage

Using this command with a specified level enables remote logging and sets the minimum severity level to be saved.

Using this command without a specified level also enables remote logging, but restores the minimum severity level to the default.

Example

Console(config)#logging trap 4

Console(config)#

37-4

Page 322
Image 322
Accton Technology ES4524D, ES4548D, 24/48-Port manual Syntax Logging trap level no logging trap, Disabled Level 7