ADTRAN TSU 600 user manual Internal Timing, Internal Clock Source

Models: TSU 600

1 133
Download 133 pages 17.65 Kb
Page 27
Image 27

Chapter 1. Introduction

Internal Timing

The TSU 600 is the source of timing. The TSU 600 is configured to use its own internal oscillator as the source of timing. Applications include private line driver circuits where one end is set to network and the other to internal. See Figure 1-7.

The internal source timing is restricted from use when a secondary interface is also used.

NETWORK

1

2

3

4

5

6

INTERFACE

SECONDARY

INTERFACE

(Option)

OSC

OPTION SLOTS

 

PBX or

TIMING SOURCE

 

Second Network

 

Figure 1-7

Internal Clock Source

61200.076L2-1

TSU 600 User Manual

15

Page 27
Image 27
ADTRAN TSU 600 user manual Internal Timing, Internal Clock Source