Chapter 4. Example Operations

Step 2. Configure DTE Port (1.1 - Nx56/64) (From Option Module)

Table 4-B provides configuration information for DTE ports.

 

 

Table 4-B

 

 

Configuration for DTE Port

 

 

 

MENU ITEM

SELECTION USED

SELECTIONS AVAILABLE

 

 

 

1)INTERFACE

V.35

V.35, RS530

 

 

 

2)RATE 56/64

56K

56K, 64K

 

 

 

3)TX CLK CNTRL

INTERNAL

INTERNAL, INTERNAL & INVERTED,

 

 

EXTERNAL

 

 

 

4)DATA

NORM

NORMAL, INVERT

 

 

 

5)CTS

FORCED ON

NORMAL, FORCE ON

 

 

 

6)DCD

FORCED ON

NORMAL, FORCE ON

 

 

 

7)DSR

FORCED ON

NORMAL, FORCE ON

 

 

 

8)"O" INHIB

ON

ON, OFF

 

 

 

Step 3. Select the number of DS0s/Port:_____12___

The number of DS0s/Port is based on the Data Rate

Table in the appendix, Configure DTE Port:

61200.076L2-1

TSU 600 User Manual

87

Page 99
Image 99
ADTRAN TSU 600 user manual Configure DTE Port 1.1 Nx56/64 From Option Module, Select the number of DS0s/Port12