ADTRAN TSU 600 user manual Pattern Generation

Models: TSU 600

1 133
Download 133 pages 17.65 Kb
Page 32
Image 32

Chapter 1. Introduction

Pattern Generation

The TSU 600 offers two available test patterns: QRSS and 511.

QRSS Pattern

The QRSS pattern is commonly used to simulate real data in T1 interfaces. This pattern can be assigned to appear in all DS0s or only in TST DS0s. When QRSS is set in all DS0s and one of the network loopbacks previously described is activated at the far end, a total end-to-end integrity check can be run without the need for any external test equipment. When QRSS is assigned to TST DS0s, an integrity check of the link can be run along with normal data flow. The TST DS0s are user assigned as part of the DS0 Map.

511 Pattern

The 511 pattern is generated and checked by an Nx56/64 serial interface option card. It only appears in the DS0s assigned to the Nx56/64 port which is generating the pattern. When used in conjunction with the port loopback at the far end as previously described, an end-to-end integrity check can be made on the DTE ports.

20

TSU 600 User Manual

61200.076L2-1

Page 32
Image 32
ADTRAN TSU 600 user manual Pattern Generation