Chapter 1. Introduction

Identification of Rear Panel Layout

The configuration of the rear panel of the TSU 600AC and TSU 600DC is shown in Figure 1-2.

1

2

3

TSU 600AC (PN 1200076L2)

 

 

 

 

MODULE 1

MODULE 4

CONTROL/

 

 

 

 

 

MODULE 2

MODULE 5

CHAIN

 

 

IN OUT MON NETWORK

MODULE 3

MODULE 6

IN

OUT

 

 

 

 

 

 

 

 

NX 56/64

NX 56/64

PORT X.1

PORT X.2

DUAL

 

DUAL

 

 

 

FXS

PORT X.3

PORT X.1

PORT X.2

FXS

 

 

 

 

 

 

PORT X.3

PORT X.4

 

V.35

V.35

 

 

 

 

 

 

 

 

 

 

 

 

SEC. NI

IN

OUT MON

 

 

NX 56/64

 

 

 

 

 

 

 

 

PORT X.1

 

 

 

 

PORT X.2

 

 

DS-1

 

 

 

 

V.35

4

 

5

 

 

 

 

 

1

2

 

 

3

 

 

 

CAUTION-RISK OF

ELECTRIC SHOCK

SUPPLEMENTAL EARTH GROUND MUST

BE CONNECTED PRIOR TO CONNECTION OF

ON TELECOMMUNICATIONS WIRING.

OFF

5A/250V

115VAC

60HZ

CAUTION:

FOR CONTINUED PROTECTION

AGAINST RISK OF FIRE, REPLACE

ONLY WITH SAME TYPE AND RATING

OF FUSE.

6 7a 8a

 

 

 

 

 

 

 

 

TSU 600DC (PN 1200076L2#DC)

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION-RISK OF

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC SHOCK

 

 

 

MODULE 1

MODULE 4

CONTROL/

 

 

 

 

 

 

SUPPLEMENTAL EARTH GROUND MUST

 

 

 

 

 

 

 

 

ON

BE CONNECTED PRIOR TO CONNECTION OF

 

 

 

 

 

 

 

 

 

 

TELECOMMUNICATIONS WIRING.

 

 

 

MODULE 2

MODULE 5

CHAIN

 

 

 

 

 

 

 

 

IN

OUT MON

NETWORK

MODULE 3

MODULE 6

 

IN

 

OUT

 

 

 

 

 

NX 56/64

 

 

NX 56/64

DUAL

PORT X.1

PORT X.2

DUAL

 

OFF

 

 

 

 

 

 

 

 

FXS

PORT X.3

 

 

 

PORT X.1

 

 

PORT X.2

FXS

 

 

 

 

 

 

 

 

 

 

 

 

 

PORT X.3

PORT X.4

 

 

 

 

V.35

 

 

V.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5A/250V

 

 

 

 

 

 

 

 

 

 

 

 

 

24/48V DC

 

 

 

 

 

 

 

 

 

 

 

 

+

-

 

 

 

 

SEC. NI

 

IN

OUT MON

 

NX 56/64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORT X.1

 

 

 

 

 

PORT X.2

CAUTION: FOR CONTINUED PROTECTION AGAINST RISK

 

 

 

 

 

 

 

 

 

OF FIRE REPLACE ONLY WITH SAME TYPE AND RATING

 

 

 

 

DS-1

 

 

 

 

 

V.35

OF FUSE.

 

 

 

 

 

 

 

 

 

 

 

 

TO BE INSTALLED ONLY IN RESTRICTED ARES

 

 

 

 

 

 

 

 

 

 

 

 

(DEDICATED EQUIP ROOMS, EQUIP CLOSETS OR

 

 

 

 

 

 

 

 

 

 

 

 

THE LIKE)

4

 

 

 

5

 

 

 

 

 

 

6 7b 8b

LEGEND

1.Monitor/Test Jacks for T1

2.T1 Network Connection

3.Control-In/Out Connection

4.Blank Panel Covering on Unused Option Slot

5.Example of Option Modules Installed

6.Power Switch

7a. .5A/250V Fuse

7b. 5A/250V Fuse

8a. Power Cord (AC Unit)

8b. Power Input Terminals (DC Unit)

Figure 1-2

TSU 600 Rear Panel

61200.076L2-1

TSU 600 User Manual

5

Page 17
Image 17
ADTRAN user manual Identification of Rear Panel Layout, TSU 600 Rear Panel