Chapter 3. Operation

XMIT PRM

Enables and disables the sending of PRM data on the facility data link (FDL). The PRM data continues to be collected even if XMIT PRM is disabled (possible only with ESF Format).

Options: Off, On.

CLOCK SOURCE

Selects the clock source for transmission toward the network from the NI.

Options: Network, Base DTE, Internal, and Secondary (SI).

Base DTE and Internal are available only if no secondary interface is installed.

SET LBO

Selects the line build out for the network interface. In AUTO mode, the TSU 600 sets the LBO based on the strength of the receive signal and displays the selected value.

Options: 0.0 dB, 7.5 dB, 15 dB, 22 dB, Auto.

INBAND LPBCK

Sets unit to accept or reject the in-band loop up and loop down codes as defined in ANSI T1.403. This is a line loopback.

Options: Accept, Reject.

BIT STUFFING

When enabled, bit stuffing causes the TSU 600 to monitor for ones (1s) density violations and insert a one (1) when needed to maintain ones at 12.5 %.

Options: Enable, Disable.