12 | Patch Release Note |
PCR: 03852 | Module: IPG, IPV6 | Level: 2 |
PIM SM did not establish a BSR candidate between two AR720 routers with
PPP over SYN. This issue has been resolved.
PCR: 03854 | Module: SWI | Level: 2 |
When INGRESSLIMIT parameter in the SET SWITCH PORT command was set to 64kbps, the switch received packets intermittently rather than continuously. This issue has been resolved.
PCR: 03855 | Module: IPG | Level: 2 |
Previously, an IP multicast stream destined for an IP multicast group was forwarded out ports in the All Groups IGMP snooping entry even after this entry had timed out. This issue has been resolved.
PCR: 03861 | Module: IPV6 | Level: 2 |
When a connector was plugged into one physical interface, the RIPng request packet was erroneously transmitted from all interfaces on the switch. This issue has been resolved.
PCR: 03864 | Module: BGP | Level: 2 |
BGP sent Update packets when the local host route table changed but did not affect BGP. Also, BGP did not send Withdrawn packets when there was a change in the best route. These issues have been resolved.
PCR: 03865 | Module: FIREWALL | Level: 2 |
When dual firewall policies were defined, public to private passive mode
FTP transfers sometimes failed. This issue has been resolved.
PCR: 03867 | Module: BGP | Level: 2 |
BGP sometimes chose routes with an infinite metric over routes with a finite metric when selecting the best local route. This issue has been resolved.
PCR: 03870 Module: SWI, VLAN | Level: 3 |
On Rapier 48i switches, mirror port information was repeated in the output of the SHOW VLAN command. This issue has been resolved.
PCR: 03875 | Module: IPG | Level: 2 |
Sometimes OSPF routes were not entered in the IP route table. This issue has been resolved.
PCR: 03888 | Module: DHCP, TELNET | Level: 2 |
When the device was configured as a DHCP server, a fatal error sometimes occurred when a telnet session to the device was closed while DHCP was reclaiming IP addresses. Also, a telnet error message displayed an incorrect value when a telnet command line parameter was repeated (for example, SHOW TELNET TELNET). These issues have been resolved.
PCR: 03896 | Module: TTY | Level: 3 |
A fatal error occurred when a long string of text was pasted over an existing long string of text at the CLI. This issue has been resolved.