12

Patch Release Note

PCR: 03852

Module: IPG, IPV6

Level: 2

PIM SM did not establish a BSR candidate between two AR720 routers with

PPP over SYN. This issue has been resolved.

PCR: 03854

Module: SWI

Level: 2

When INGRESSLIMIT parameter in the SET SWITCH PORT command was set to 64kbps, the switch received packets intermittently rather than continuously. This issue has been resolved.

PCR: 03855

Module: IPG

Level: 2

Previously, an IP multicast stream destined for an IP multicast group was forwarded out ports in the All Groups IGMP snooping entry even after this entry had timed out. This issue has been resolved.

PCR: 03861

Module: IPV6

Level: 2

When a connector was plugged into one physical interface, the RIPng request packet was erroneously transmitted from all interfaces on the switch. This issue has been resolved.

PCR: 03864

Module: BGP

Level: 2

BGP sent Update packets when the local host route table changed but did not affect BGP. Also, BGP did not send Withdrawn packets when there was a change in the best route. These issues have been resolved.

PCR: 03865

Module: FIREWALL

Level: 2

When dual firewall policies were defined, public to private passive mode

FTP transfers sometimes failed. This issue has been resolved.

PCR: 03867

Module: BGP

Level: 2

BGP sometimes chose routes with an infinite metric over routes with a finite metric when selecting the best local route. This issue has been resolved.

PCR: 03870 Module: SWI, VLAN

Level: 3

On Rapier 48i switches, mirror port information was repeated in the output of the SHOW VLAN command. This issue has been resolved.

PCR: 03875

Module: IPG

Level: 2

Sometimes OSPF routes were not entered in the IP route table. This issue has been resolved.

PCR: 03888

Module: DHCP, TELNET

Level: 2

When the device was configured as a DHCP server, a fatal error sometimes occurred when a telnet session to the device was closed while DHCP was reclaiming IP addresses. Also, a telnet error message displayed an incorrect value when a telnet command line parameter was repeated (for example, SHOW TELNET TELNET). These issues have been resolved.

PCR: 03896

Module: TTY

Level: 3

A fatal error occurred when a long string of text was pasted over an existing long string of text at the CLI. This issue has been resolved.

Patch 86251-08 for Software Release 2.5.1 C613-10356-00 REV I

Page 12
Image 12
Allied Telesis 86251-08 manual PCR Module IPG, IPV6 Level, PCR 03870 Module SWI, Vlan Level, PCR Module DHCP, Telnet Level