8

Patch Release Note

PCR: 31106 Module: MLD

Level: 2

When the device received a version 1 Query packet, it become a non-querier on that interface, even if it should have remained as the querier. This issue has been resolved.

PCR: 31118

Module: SWI

Level: 2

When the TYPE parameter was specified for the ADD SWITCH L3FILTER command, the type was sometimes a different value in the device’s hardware table. This issue has been resolved.

PCR: 31129

Module: IPX2

Level: 2

A fatal error occurred if IPX was disabled and then re-enabled when there was a high rate of incoming IPX traffic on the device. This issue has been resolved.

PCR: 31162

Module: SWI

Level: 2

A STP topology change incorrectly deleted static ARP entries. This issue has been resolved.

PCR: 31167

Module: IPG

Level: 2

IP MVR member ports were not timing out. MVR member ports now timeout in the same way as IP IGMP ports. The timeout values are configured by IGMP. Also, IGMP interfaces were incorrectly being enabled and disabled by MVR. This issue has been resolved.

Features in 86251-07

Patch file details are listed in Table 2:

Table 2: Patch file details for Patch 86251-07.

Base Software Release File

86s-251.rez

 

 

Patch Release Date

18-Sep-2003

 

 

Compressed Patch File Name

86251-07.paz

 

 

Compressed Patch File Size

487620 bytes

 

 

Patch 86251-07 includes all issues resolved and enhancements released in previous patches for Software Release 2.5.1, and the following enhancements:

PCR: 02414 Module: IPV6, SWI, IPG, VLAN

MLD snooping is now supported on AT-9800 Series Switches and Rapier i

Series Switches. For details, see MLD Snooping” on page 57.

PCR: 03445

Module: IPG

Support has been added for the Ping Polling enhancement. For details, see Ping Polling of Device Reachability” on page 58

Patch 86251-08 for Software Release 2.5.1 C613-10356-00 REV I

Page 8
Image 8
Allied Telesis 86251-08 manual PCR 31106 Module MLD Level, PCR Module IPX2 Level, PCR 02414 Module IPV6, SWI, IPG, Vlan