Patch 86251-08 For Rapier Series Switches 21
Patch 86251-08 for Software Release 2.5.1
C613-10356-00 REV I
When a Finisar 8521 GBIC was used in an AT-A42/GBIC uplink module the
link LED did not correctly show the link status. This issue has been
resolved.
IPv6 was selecting routes on interfaces that were down. This issue has been
resolved.
IPv6 static tunnels remained in the Tentative state and did not change to the
Preferred state. This issue has been resolved.
A fatal error sometimes occurred when the ENABLE STP PORT command
was executed. This issue has been resolved.
A fatal error occurred when the SHOW IPV6 MLD INTERFACE command
was executed after the interface had been destroyed. This issue has been
resolved.
A fatal error occurred when a Set request with an incorrect object ID value
was received by SNMPv2c. This issue has been resolved.
IGMP Query messages were sent over an interface even if IGMP had been
disabled on that interface. This issue has been resolved.
Packet forwarding between switch chips on Rapier 48 switches sometimes
failed if ingress rate limiting was set below 1 Mb/s. This was caused by
packets receiving a bad hop count between switch chips via the CPU,
causing packets to be discarded. This issue has been resolved.
Executing the DISABLE SWITCH PORT command on a port that was the
source of a mirror port did not disable the mirror port. This issue has been
resolved.
Equal Cost Multi-Path (ECMP) routing selected a route with an infinite
metric, so that forwarded packets using that route were discarded. This
issue has been resolved.
BGP advertised interface routes when the corresponding interface was
down. This issue has been resolved.
PCR: 03631 Module: SWI Level: 4
PCR: 03635 Module: IPV6 Level: 1
PCR: 03637 Module: IPV6 Level: 1
PCR: 03640 Module: STP Level: 2
PCR: 03646 Module: IPv6 Level: 1
PCR: 03647 Module: SNMP Level: 2
PCR: 03650 Module: IPG Level: 3
PCR: 03652 Module: SWI Level: 2
PCR: 03657 Module: SWI Level: 3
PCR: 03662 Module: IPG Level: 1
PCR: 03666 Module: BGP Level: 3