100 en Appendix

VOT-320

 

 

Serial interface (upper 6-pin terminal block)

The pin assignment of the serial interface depends on the interface mode used (see

Section 5.33 Advanced Mode: COM1, page 68).

Pin No.

Contact

RS-232 mode

RS-422 mode

RS-485 mode

 

 

 

 

 

1

RXD

RxD (receive data)

RxD+ (receive data plus)

Data+

 

 

 

 

 

2

CTS

CTS (clear to send)

RxD– (receive data minus)

Data–

 

 

 

 

 

3

RTS

RTS

TxD+ (transmit data plus)

Data+

 

 

 

 

 

4

TXD

TxD (transmit data)

TxD– (transmit data minus)

Data–

 

 

 

 

 

5

GND

GND (ground)

 

 

 

 

 

6

GND

 

 

 

 

 

Relay and alarm (lower 6-pin terminal block)

Pin No.

Contact

Function

 

 

 

1

R1

Relay output 1

 

 

 

2

R1

Relay output 1

 

 

 

3

R2

Relay output 2

 

 

 

4

R2

Relay output 2

 

 

 

5

IN1

Input alarm 1

 

 

 

6

IN2

Input alarm 2

 

 

 

Connect each alarm input to a ground contact (GND) on the upper 6-pin terminal block when connecting alarm inputs.