Configuration using a Web browser en 49 | |
|
|
Settings for selected streams
The settings in this settings group only refer to the streams selected in the list field. You can select both streams.
Recording includes
You can specify whether, in addition to video data, metadata (for example alarms, VCA data and serial data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity.
CAUTION!
Without metadata, it is not possible to include video content analysis in recordings.
Standard recording
Here you can select the mode for standard recordings.
If you select Continuous, the recording proceeds continuously. If the maximum memory capacity is reached, older recordings will automatically be overwritten. If you select the Pre- alarm option, the unit uses a special recording mode for optimal usage of storage capacity: As soon as a time window for alarm recording begins, recording takes place continuously on one segment that corresponds in size to a complete alarm sequence (pre- and
If you select Off, no automatic recording takes place.
CAUTION!
You can specify limitations for overwriting older recordings in Continuous mode by configuring the retention time (see Section 5.21 Advanced Mode: Retention Time, page 50).
Stream
Here you can select the data stream that is to be used for standard recordings. You can select the data stream for alarm recordings separately and independently of this (see Section Alarm stream, page 49).
Pre-alarm time
You can select the required
Post-alarm time
You can select the required
Alarm stream
Here you can select the data stream that is to be used for alarm recordings. You can select the data stream for standard recordings separately and independently of this (see
Section Stream, page 49).
with encoding interval from profile
You can select an alternative encoding interval for the data stream for alarm recordings. Otherwise the encoding interval of the selected encoder profile is used (see
Section 5.17 Advanced Mode: Encoder Profile, page 40).
Bosch Sicherheitssysteme GmbH | Installation and Operating Manual | DOC V4.5 2010.09 |