96 en Appendix

VOT-320

 

 

Malfunction

Possible causes

Recommended solution

 

 

 

No connection

The unit's configuration.

Check all configuration

established, no image

 

parameters.

transmission.

 

 

Faulty installation.

Check all cables, plugs, contacts

 

 

and connections.

 

 

 

 

Wrong IP address.

Check the IP addresses

 

 

(terminal program).

 

 

 

 

Faulty data transmission within

Check the data transmission

 

the LAN.

with ping.

 

 

 

 

The maximum number of

Wait until there is a free

 

connections has been reached.

connection and then call the

 

 

sender again.

 

 

 

The camera does not

Alarm source is not selected.

Select possible alarm sources on

report an alarm.

 

the Alarm Inputs configuration

 

 

page.

 

 

 

 

No alarm response specified.

Specify the desired alarm

 

 

response on the Alarm

 

 

Connections configuration page,

 

 

change the IP address if

 

 

necessary.

 

 

 

Control of pan/tilt or

The cable connection between

Check all cable connections and

other units is not

the serial interface and the

ensure all plugs are properly

possible.

connected unit is not correct.

fitted.

 

 

 

 

The interface parameters do not

Make sure that the settings of all

 

match those of the other unit

units involved are compatible.

 

connected.

 

 

 

 

The camera is not

Power failure during

Have the unit checked by

operational after a

programming by firmware file.

Customer Service and replace if

firmware upload.

 

necessary.

 

 

 

 

Incorrect firmware file.

Enter the IP address of the unit

 

 

followed by /main.htm in your

 

 

Web browser and repeat the

 

 

upload.

 

 

 

Placeholder with a red

JVM not installed on your

Install Sun JVM from the

cross instead of the

computer or not activated.

product CD.

ActiveX components.

 

 

 

 

 

Web browser contains

Active proxy server in network.

Create a rule in the local

empty fields.

 

computer's proxy settings to

 

 

exclude local IP addresses.

 

 

 

The CONNECT LED

Firmware upload failed.

Repeat firmware upload.

flashes red.

 

 

 

 

 